1. Pallet Arrival at a Conveyor Workstation
A conveyor workstation needs a mechanical stop for an arriving workpiece carrier. The round trunnion rod presents the stopping interface, while the cylinder’s 20 mm stroke provides withdrawal travel. The 6280 N impact rating applies to force on the extended rod; permissible carrier mass depends on speed, buffering and the manufacturer’s mounting conditions, rather than that force alone.
Problem Solved
The raised trunnion rod provides a stopping interface and retracts to release the carrier, supporting controlled workstation entry within the documented impact, mounting and conveyor-loading conditions.
Trunnion piston rod
20 mm stroke
6280 N impact rating
2. Release from a Continuing Conveyor Load
A conveyor may continue applying a lateral friction load after a carrier has stopped. The single-acting pulling cylinder withdraws its round trunnion rod, with lateral switching force specified separately from impact force. The current exact-part datasheet lists 1570 N permissible lateral force during switching; the catalog explains that this condition is evaluated after impact and depends on available pneumatic pressure.
Problem Solved
Separating the withdrawal load from the arrival impact supports a stop-release mechanism based on the relevant lateral switching condition, while pneumatic pulling operation supplies the release movement.
Single-acting pulling
Trunnion rod
Lateral switching load
3. Position-Confirmed Transfer-Line Sequencing
A transfer line needs to coordinate a carrier-release command with the stopper’s actual piston position. This cylinder supports proximity-switch detection to observe its 20 mm travel. The controller can use compatible switch inputs to distinguish extended and withdrawn conditions, while the documented 5 Hz maximum cycle frequency defines a component limit for sequence planning.
Problem Solved
Position-detection capability provides feedback from the cylinder movement, allowing the transfer sequence to coordinate release with the observed piston position instead of relying only on a timed command.
Proximity-switch detection
20 mm stroke
5 Hz maximum