1. Commanded Supply to an Air-Blast Branch
A machine process needs an air blast only during selected sequence steps. The normally closed 3/2-way function supplies the branch under electrical command and provides the alternate exhaust routing. Its G1/4 working ports and 1000 l/min nominal flow characterize the connection, while pneumatic spring reset returns the valve to its normal switching state with pilot air available.
Problem Solved
Normally closed routing lets the electrical command select when the air branch receives supply, supporting a sequenced blast circuit with a defined pneumatic return mechanism.
3/2-way normally closed
1000 l/min nominal
Pneumatic spring reset
2. Single-Acting Fixture Actuation
A fixture uses a single-acting pneumatic actuator that extends under air pressure and returns when its working line is vented. This normally closed 3/2-way valve provides those supply-and-exhaust states through G1/4 ports. A 24 V DC command changes the routing, while internal piloting operates within the documented 2.5–10 bar working-pressure range.
Problem Solved
Normally closed supply routing and an exhaust state provide the pneumatic commands for a single-acting fixture, allowing the machine sequence to pressurize and release its working line.
3/2-way normally closed
G1/4 ports
Internal pilot
3. Manual Commissioning of a Pneumatic Station
During commissioning, a station needs to exercise its pneumatic branch while checking the installed control sequence. Detenting and non-detenting manual override allow local valve actuation, and pneumatic spring reset provides the normally closed return function with pilot air available. Manifold-rail or through-hole mounting positions the valve in the control assembly, while the Type C connector provides its electrical interface.
Problem Solved
Local manual actuation lets the pneumatic branch be exercised at the valve during commissioning, supporting observation of the connected mechanism alongside the electrical control checks.
Manual override
Normally closed return
Type C connection