Sale!

Festo 571333 Single 5/2 Solenoid Valve, 20 mm, 24 V DC

Original price was: USD 126.36.Current price is: USD 109.20.

Mechanical spring-reset 5/2 valve with reversible flow, vacuum suitability, MPA-S/QS-8 670 l/min or MPA-L/QS-10 840 l/min nominal flow and IP65 when mounted.

SKU Festo-571333 Category
Festo Solenoid Valves

Festo VMPA2-M1H-MS-PI Single-Solenoid Valve

BrandFesto
Model IdentifierVMPA2-M1H-MS-PI
Official Part Number571333

Technical Overview

The Festo VMPA2-M1H-MS-PI is a 20 mm, single-solenoid 5/2-way valve with mechanical spring reset and 24 V DC actuation. Manufacturer flow notes specify 670 l/min for MPA-S and 840 l/min for MPA-L installations. Its −0.9 to 8 bar working range, reversible flow and vacuum suitability are separate from the 3–8 bar pilot-pressure requirement. Switching times are 8 ms on and 36 ms off. The 100 g die-cast aluminium valve has NBR seals, signal indication, manual override and through-hole mounting, with IP65 protection in the mounted state and −5 to 50 °C ambient limits.

20 mm single-solenoid 5/2 valve with mechanical spring reset, 24 V DC actuation, reversible flow and platform-specific nominal-flow ratings.

Key Features

  • Single-solenoid 5/2-way switching with mechanical spring reset
  • 20 mm valve size and soft-sealed piston gate design
  • Nominal flow: MPA-S/QS-8 670 l/min; MPA-L/QS-10 840 l/min
  • 24 V DC operation with ±25% permissible voltage variation
  • −0.9 to 8 bar working pressure and separate 3–8 bar pilot pressure
  • Reversible flow direction and documented vacuum suitability
  • 8 ms switch-on and 36 ms switch-off times
  • Signal indication and detenting/non-detenting manual override
  • IP65 protection in mounted state; 0.65 Nm maximum valve-mounting torque
  • 100 g die-cast aluminium body with NBR seals; −5 to 50 °C ambient range

Provide reversible 5/2 routing and vacuum suitability in a 20 mm MPA valve, with nominal-flow data matched to the selected terminal platform.

Technical Specification Matrix

ParameterValue
Valve function5/2-way, single solenoid
Type of actuationElectrical
Valve size20 mm
Standard nominal flow rate (standardised to DIN 1343)670 l/min...840 l/min
Operating voltage24 V DC
Operating pressure-0.09 MPa...0.8 MPa; -0.9 bar...8 bar
DesignPiston gate valve
Type of resetMechanical spring
Approvalc UL us - Recognised (Oil)
Degree of protectionIP65; In mounted state; To IEC 60529
Sealing principleSoft
Mounting positionAny
Manual overrideDetenting; Non-detenting
Type of pilotingPiloted
Flow directionReversible
lapOverlap
Signal status displayYes
Pilot pressure0.3 MPa...0.8 MPa; 3 bar...8 bar
Suitability for vacuumYes
Note on standard nominal flow rateMPA-L: 840 l/min; MPA-S: 670 l/min
Standard nominal flow rate with QS-8670 l/min
Standard nominal flow rate with QS-10840 l/min
Max. switching frequency2 Hz
Switching time off36 ms
Switching time on8 ms
Max. positive test pulse with 0 signal400 µs
Max. negative test pulse with 1 signal900 µs
Permissible voltage fluctuations+/-25%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC1 - Low corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Storage temperature-20 °C...40 °C
Media temperature-5 °C...50 °C
Relative air humidityMax. 90% at 40 °C
Ambient temperature-5 °C...50 °C
Max. tightening torque for valve mounting0.65 Nm
Physical Weight (kg)0.1
Type of mountingWith through-hole
Note on materialsRoHS compliant
Material sealsNBR
Material housingDie-cast aluminium

Industrial Applications

1. Double-Acting Cylinder Direction Control

A transfer fixture needs electrical control to alternate pressure and exhaust between the two chambers of a double-acting cylinder. The valve's single-solenoid 5/2 function supplies the routing states, with mechanical spring reset. Manufacturer nominal-flow notes distinguish MPA-S and MPA-L installations, while 8 ms switch-on and 36 ms switch-off times characterise the valve response.

Problem Solved

The 5/2 routing function alternates the cylinder working connections between supply and exhaust, combining an electrical switching command and mechanical spring reset for directional control.

5/2 single solenoid Mechanical spring reset Platform-specific flow

2. Vacuum-Circuit Path Switching

A handling circuit needs a directional valve whose working paths can operate below atmospheric pressure. This model is explicitly suitable for vacuum and permits working pressure down to −0.9 bar with reversible flow. A separate 3–8 bar pilot requirement supplies the actuation condition while the working circuit follows the selected vacuum and venting connections.

Problem Solved

Documented vacuum suitability permits switching of sub-atmospheric working paths, while the separate pilot-pressure range defines the positive-pressure actuation needed for that vacuum circuit arrangement.

Vacuum suitability −0.9 bar 3–8 bar pilot

3. Valve-Station Commissioning

During assembly of a pneumatic valve station, technicians need to exercise routing states and correlate electrical commands with the installed valve. The detenting and non-detenting manual override provides local actuation, while signal indication makes the commanded condition visible. The 20 mm valve uses through-hole mounting with a specified 0.65 Nm maximum valve-mounting torque for installation.

Problem Solved

Manual actuation and visible signal indication support local routing checks during commissioning, helping technicians relate the electrical command to the selected pneumatic path at the valve station.

Manual override Signal indication 20 mm
Select your currency