1. External Gripping of Small Components
A transfer tool picks a small component by its outer faces while leaving its central opening accessible. The gripper’s two parallel jaws provide 3 mm stroke per jaw, and the G2 version supplies gripping-force backup during closing. Application-specific fingers establish the contact geometry, while the wedge mechanism synchronizes the jaw movement for the pickup and release sequence.
Problem Solved
Powered parallel closing and closing-direction force backup supply the mechanical action for an external grip, allowing shaped contact fingers to hold the component by its outer faces.
3 mm per jaw
Closing force backup
Parallel gripping
2. Repeated Component Placement in an Assembly Nest
An assembly station repeatedly brings a held component to a locating nest and needs consistent gripper movement. The HGPT-16-A-B-G2 specifies 0.03 mm repetition accuracy, with hardened-steel jaws and a wedge-shaped drive. Centring sleeves or dowel pins locate the body on its handling attachment, providing a defined mechanical reference while the nest establishes the component’s final position.
Problem Solved
Specified jaw repeatability and located mounting provide consistent mechanical interfaces for repeated placement, helping the handling attachment preserve its relationship with the assembly nest.
0.03 mm repetition
Located mounting
Hardened-steel jaws
3. Position-Observed Loading and Release
A loading mechanism must coordinate jaw movement with transfer-axis motion and fixture release. The gripper supports proximity-switch position detection so the controller can observe the selected jaw state before advancing the sequence. Documented minimum opening and closing times at 6 bar are 22 ms and 15 ms, characterizing the actuator movement within the complete handling cycle.
Problem Solved
Jaw-position detection supplies feedback for coordinating loading and release, while documented component movement times provide a basis for evaluating the gripper step in the machine sequence.
Proximity-switch detection
22 ms opening