1. Internal Gripping of Components with Accessible Openings
A transfer tool handles a component from an accessible internal opening, leaving the exterior free for the next operation. The gripper’s two parallel jaws move outward through 20 mm stroke per jaw, with 126 N total opening force at 6 bar and a 20 mm lever arm. Application-specific fingers establish the contact geometry, while the rack-and-pinion mechanism synchronizes jaw movement.
Problem Solved
Powered parallel opening supplies the mechanical action for an internal grip, allowing shaped contact fingers to handle the part while preserving access to its exterior.
20 mm per jaw
126 N opening at 6 bar / 20 mm
Parallel gripping
2. Repeated Component Placement in an Assembly Nest
An assembly station repeatedly brings a held component to a locating nest and needs consistent gripper movement. The HGPL-14-20-A-B specifies 0.03 mm repetition accuracy, with hardened-steel jaws and a double-piston drive with rack-and-pinion synchronization. Centring sleeves locate the body on its handling attachment, providing a defined mechanical reference while the nest establishes the component’s final position.
Problem Solved
Specified jaw repeatability and located mounting provide consistent mechanical interfaces for repeated placement, helping the handling attachment preserve its relationship with the assembly nest.
0.03 mm repetition
Located mounting
Hardened-steel jaws
3. Position-Observed Loading and Release
A loading mechanism must coordinate jaw movement with transfer-axis motion and fixture release. The gripper supports proximity-switch position detection so the controller can observe the selected jaw state before advancing the sequence. Documented minimum opening and closing times at 6 bar are 120 ms and 110 ms, characterizing the actuator movement within the complete handling cycle.
Problem Solved
Jaw-position detection supplies feedback for coordinating loading and release, while documented component movement times provide a basis for evaluating the gripper step in the machine sequence.
Proximity-switch detection
120 ms opening