Festo 536800 Vacuum Generator, QS-6, PNP Sensor, 92% Vacuum

USD 145.34

0.7 mm ejector with 16.2 l/min atmospheric suction, teach-in PNP NO pressure switch, −1 to 0 bar measuring range, three-pin M8 plug and open silencer.

SKU Festo-536800 Category
Festo Vacuum Generators

Festo VN-07-H-T4-PQ2-VQ2-O1-P Vacuum Generator with Sensor

BrandFesto
Model IdentifierVN-07-H-T4-PQ2-VQ2-O1-P
Official Part Number536800

Technical Overview

The Festo VN-07-H-T4-PQ2-VQ2-O1-P combines a high-vacuum ejector, piezoresistive pressure sensor and open silencer in a T-shaped assembly. Its 0.7 mm Laval nozzle provides 92% maximum vacuum at 4.4 bar and 16.2 l/min maximum atmospheric suction flow at a separate 3 bar condition. The integrated sensor measures relative pressure from −1 to 0 bar and provides a teachable PNP normally open threshold output with fixed hysteresis. QS-6 connections serve air and vacuum, with a three-pin M8 electrical interface operating at 15–30 V DC. The 36 g unit has IP40 protection, a 16 mm mounting grid and a 0–50 °C ambient range.

QS-6 high-vacuum ejector with integrated teach-in PNP NO pressure sensor, 92% maximum vacuum and open silencer.

Key Features

  • T-shaped high-vacuum ejector with 0.7 mm Laval nozzle
  • 92% maximum vacuum at 4.4 bar supply
  • 16.2 l/min maximum atmospheric suction flow at 3 bar supply
  • Integrated piezoresistive relative-pressure sensor; −1 to 0 bar range
  • Teach-in PNP normally open threshold output with fixed hysteresis
  • ±1.5% FS accuracy; 2% FS stated hysteresis
  • 15–30 V DC operation, three-pin M8 plug and 100 mA maximum output
  • 4 ms sensor switch-on/off times
  • QS-6 air/vacuum connections; open silencer with 66 dB(A) at nominal pressure
  • 36 g IP40 assembly; 16 mm grid pitch; through-hole mounting

Generate local vacuum and return a teachable PNP threshold signal from one 36 g ejector with QS-6 connections and integrated pressure sensing.

Technical Specification Matrix

ParameterValue
Nominal size, Laval nozzle0.7 mm
Mounting grid pitch16 mm
Silencer designOpen
Mounting positionAny
Ejector characteristicHigh vacuum; Standard
Integrated functionPressure sensor; Open silencer
DesignT-shape
Short circuit current ratingPulsed
Measured variableRelative pressure
Measuring principlePiezoresistive
Measurement methodrelatively
Switching element functionN/O contact
Switching functionThreshold value comparator; Threshold value with fixed hysteresis
Reverse polarity protectionFor all electrical connections
Display typeLED
Setting range threshold value-100 kPa...0 kPa; -1 bar...0 bar; -14.5 psi...0 psi
Setting optionsTeach-in
Switching status indicationLED
Operating pressure for max. suction flow rate0.3 MPa; 3 bar; 43.5 psi
Operating pressure0.1 MPa...0.8 MPa; 1 bar...8 bar; 14.5 psi...116 psi
Operating pressure for max. vacuum0.44 MPa; 4.4 bar; 63.8 psi
Max. vacuum92 %
Nominal operating pressure0.6 MPa; 6 bar; 87 psi
Max. suction flow rate against atmosphere16.2 l/min
Switch-off time4 ms
Switch-on time4 ms
Operational voltage range DC15 V...30 V
Inductive protective circuitAdapted to MZ, MY, ME coils
Max. output current100 mA
Off-state current0.3 mA
Residual ripple10%
Switching outputPNP
Voltage drop1.5 V
Overload protectionAvailable
ApprovalRCM
KC markKC-EMV
CE mark (see declaration of conformity)To EU EMC Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation not possible
Corrosion resistance class CRC1 - Low corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Media temperature0 °C...60 °C
Recommended cleaning/purificationSoapy water
Sound pressure level at nominal operating pressure66 dB(A)
Degree of protectionIP40
Ambient temperature0 °C...50 °C
Max. tightening torque0.6 Nm
Pressure measuring range-100 kPa...0 kPa; -1 bar...0 bar; -14.5 psi...0 psi
Physical Weight (kg)0.036
Accuracy in ± % FS1.5 %FS
Hysteresis in ± %FS2 %FS
Long-term drift±0.5 % FS max.
Temperature cooefficient of switching point0.05 %/K
Electrical connection3-pin; M8
Type of mountingWith through-hole
Pneumatic connection, port 1QS-6
Pneumatic connection, port 3Open silencer
Vacuum connectionQS-6
Material sealsNBR
Material receiver nozzlePOM
Material housingReinforced POM
Material fibre-opticMakrolon®
Material silencerPE
Material connector housingBrass; PA; Chrome-plated and nickel-plated
Material transmitter nozzleWrought aluminium alloy
Material keypadPOM
Material fittingBrass; nickel-plated

Industrial Applications

1. Vacuum-Confirmed Component Pickup

A handling head needs local vacuum generation and an electrical indication when its selected vacuum threshold is reached. The ejector supplies the suction circuit through a QS-6 connection, while its integrated piezoresistive sensor delivers a teachable PNP normally open output. The controller can use that threshold event to coordinate the pickup sequence with the surrounding transfer motion.

Problem Solved

Integrated generation and threshold sensing place the vacuum source and its electrical observation at one unit, supporting a pickup sequence based on measured pressure rather than supply timing alone.

Integrated pressure sensor Teach-in PNP NO QS-6 vacuum

2. Suction Holding in an Assembly Fixture

An assembly fixture uses a suitably sealed suction support to retain a component while another tool performs an operation. This generator supplies local vacuum with a high-vacuum characteristic and an integrated open silencer. Its 92% maximum vacuum and 16.2 l/min maximum atmospheric suction flow characterize separate operating conditions, while through-hole mounting locates the 36 g assembly at the fixture.

Problem Solved

A dedicated compressed-air ejector supplies the fixture suction circuit locally, with documented vacuum and flow characteristics and integrated exhaust silencing for the tooling arrangement.

92% maximum vacuum 16.2 l/min atmospheric suction Through-hole mounting

3. Vacuum Threshold Observation on a Pneumatic Test Bench

A test bench needs to observe whether a small vacuum circuit reaches a selected negative-pressure threshold. The integrated sensor measures relative pressure from −1 to 0 bar and supports teach-in threshold setting. Its PNP output and 4 ms switching times provide an electrical event for the bench controller, with fixed hysteresis separating the switching transitions.

Problem Solved

The pressure switch converts the selected vacuum threshold into a controller event, supporting a qualitative pressure-condition check without treating the output as a calibrated leak-rate measurement.

−1 to 0 bar Teach-in threshold Fixed hysteresis
Select your currency