Festo 548002 Quick Exhaust Valve, QS-8 Supply, G1/4 Drive

USD 145.34

Quick-exhaust valve with QS-8 supply, G1/4 drive connection, integrated silencer, 2500 l/min exhaust flow at 6→0 bar and 800 l/min feed flow at 6→5 bar.

SKU Festo-548002 Category
Festo Quick Exhaust Valves

Festo VBQF-U-G14-Q8 Quick Exhaust Valve

BrandFesto
Model IdentifierVBQF-U-G14-Q8
Official Part Number548002

Technical Overview

The Festo VBQF-U-G14-Q8 is a screw-in quick-exhaust valve with QS-8 supply and G1/4 working connections, a 7 mm nominal size and an integrated silencer. Compressed air flows from the control valve toward the drive; when pressure at port 1 drops, the drive exhausts locally from port 2 to port 3. The exact valve provides 2500 l/min nominal exhaust flow at 6-to-0 bar and 800 l/min nominal feed flow at 6-to-5 bar. Its 232 g die-cast aluminium/zinc assembly uses NBR seals and operates at 0.5–10 bar. Direct actuator-port mounting supports the quick-exhaust function, with any mounting position and a −10 to 60 °C ambient/media range.

G1/4 quick-exhaust valve with integrated silencer, 2500 l/min nominal exhaust flow at 6→0 bar and 232 g product weight.

Key Features

  • Quick-exhaust function with local working-port discharge
  • Integrated silencer; 75 dB(A) published sound pressure level
  • QS-8 supply connection and G1/4 working connection
  • 2500 l/min standard nominal exhaust flow at 6→0 bar
  • 800 l/min standard nominal feed flow at 6→5 bar
  • 7 mm nominal size and 0.5–10 bar operating range
  • Screw-in mounting in any position; direct drive-port installation for quick exhaust
  • Die-cast aluminium/zinc housing with NBR seals
  • 232 g product weight; −10 to 60 °C ambient/media range
  • Class 4 cleanroom suitability according to ISO 14644-1, measured to ISO 14644-14

Exhaust a pneumatic drive locally through a G1/4 valve with integrated silencer and 2500 l/min nominal exhaust flow at 6→0 bar.

Technical Specification Matrix

ParameterValue
Valve functionQuick exhaust
Selection of additional functionsWith silencer
Pneumatic connection, port 1QS-8
Pneumatic connection, port 2G1/4
Type of mountingScrew-in
Standard nominal exhaust flow at 6→0 bar2500 l/min
Standard nominal feed flow at 6→5 bar800 l/min
Operating pressure0.5 bar...10 bar
Ambient temperature-10 °C...60 °C
Material housingDie-cast aluminium; Die-cast zinc
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Nominal size7 mm
Mounting positionAny
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Corrosion resistance class CRC1 - Low corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Cleanroom suitability, measured according to ISO 14644-14Class 4 according to ISO 14644-1
Media temperature-10 °C...60 °C
Sound pressure level75 dB(A)
Physical Weight (kg)0.232
Note on materialsRoHS compliant
Material sealsNBR

Industrial Applications

1. Local Exhaust for Spring-return Cylinder Retraction

A single-acting cylinder must return under spring force after its air command is removed. Mounted at the actuator port, the quick-exhaust valve routes air from the cylinder directly to its local exhaust as supply pressure falls. Its G1/4 connections and 2500 l/min nominal exhaust rating at 6-to-0 bar define the component interface and flow characteristic for evaluating the return circuit.

Problem Solved

A local exhaust path lets the spring-return chamber discharge at the actuator, avoiding the need for that air to return through the full upstream control line.

Local actuator exhaust G1/4 2500 l/min exhaust at 6→0 bar

2. Exhausting the Opposing Chamber of a Double-acting Drive

A double-acting cylinder fills one chamber while the opposite chamber needs to exhaust during the commanded stroke. A quick-exhaust valve at the selected chamber provides a local discharge route when its supply-line pressure drops. This G1/4 version separates its 800 l/min feed and 2500 l/min exhaust ratings, giving specific data for evaluating both phases of that chamber's pneumatic operation.

Problem Solved

The valve combines chamber filling and local exhaust routing, supplying a defined discharge path for the opposing chamber while retaining the normal feed connection.

Feed/exhaust routing 800 l/min feed at 6→5 bar Local discharge

3. Actuator Exhaust with a Remote Directional Valve

A machine layout places its directional control valve away from the actuator, creating a longer control-line route for exhaust air. Installing the quick-exhaust valve directly at the actuator provides the manufacturer-described local discharge path through port 3. Screw-in G1/4 mounting and any-position installation support that placement, with separate flow data for the supply and exhaust paths.

Problem Solved

Local exhaust routing bypasses the remote directional-valve return path for actuator discharge, allowing the pneumatic layout to keep its control valve remote while exhausting at the drive.

Remote control-valve layout Screw-in mounting Integrated silencer
Select your currency