Festo 2201471 CTEU-PN PROFINET Bus Node, 24 V DC

USD 424.06

PROFINET bus node with two D-coded M12 sockets, isolated 100 Mbit/s Ethernet, 64-byte input/output address limits, GSDML support and 18–30 V DC supply.

Festo Remote I/O and Network Interface Components

Festo CTEU-PN PROFINET Bus Node

BrandFesto
Model IdentifierCTEU-PN
Official Part Number2201471

Technical Overview

The Festo CTEU-PN connects compatible I-Port equipment to a PROFINET network through an electrically isolated 100 Mbit/s Ethernet interface. Two four-contact D-coded M12 sockets provide the network connections, with maximum input and output address volumes of 64 bytes each. GSDML configuration support accompanies PROFINET RT, conformance class C, IRT, fast start-up and shared-device functions. Communication errors, undervoltage and system diagnostics are supported by local supply, I-Port and network LEDs. Its five-pin A-coded M12 power input operates at 18–30 V DC, nominally 24 V DC. The 93 g PA-housed module measures 91 × 40 × 50 mm in length, width and height and provides IP65/IP67 protection when mounted with unused connections sealed.

PROFINET bus node with two D-coded M12 network sockets, isolated 100 Mbit/s Ethernet, 64-byte input/output address limits and 18–30 V DC supply.

Key Features

  • PROFINET RT over an isolated 100 Mbit/s Ethernet interface
  • Two four-contact D-coded M12×1 network sockets
  • Maximum input and output address volumes of 64 bytes each
  • Internal cycle time: 1 ms per byte of user data
  • GSDML configuration support and conformance class C
  • Fast start-up, PROFINET IRT and shared-device functions
  • LLDP, MRP, PROFIenergy, SNMP and web-server functions
  • Communication-error, undervoltage and system diagnostics with local LEDs
  • Five-pin A-coded M12 power input; 18–30 V DC, nominally 24 V DC, maximum 4 A supply
  • 93 g PA housing; IP65/IP67 when mounted with unused connections sealed

Connect compatible I-Port equipment to PROFINET through two M12 network sockets with isolated Ethernet and local diagnostic indication.

Technical Specification Matrix

ParameterValue
ProtocolPROFINET
Mounting grid pitch40 mm
Type of mountingOn electrical interface; On electrical connection block
Physical Weight (kg)0.093
Ambient temperature0 °C...50 °C
Storage temperature-20 °C...70 °C
Degree of protectionIP65; IP67
Note on degree of protectionIn mounted state; Unused connections sealed
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364 zone III
CE mark (see declaration of conformity)To EU EMC Directive; In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC; To UK RoHS instructions
KC markKC-EMV
ApprovalRCM; c UL us - Listed (Oil)
Note on materialsRoHS compliant
Material housingPA
LED display, product-specificPS: Operating voltage for electronics and load supply; X1: System status of module at I-Port 1; X2: System status of module at I-Port 2
LED display, bus-specificNF: Network error; TP1: Network active port 1; TP2: Network active port 2
DiagnosisCommunication error; System diagnostics; Undervoltage
Fieldbus interfaceEthernet
Field bus, protocolPROFINET RT
Field bus, connection type2x socket
Field bus, connection systemM12x1, D-coded to EN 61076-2-101
Field bus, connection pattern4
Field bus interface, electrical isolationYes
Field bus interface, transmission rate100 Mbit/s
Max. address volume, inputs64 Byte
Max. address volume, outputs64 Byte
Internal cycle time1 ms per 1 byte of user data
Configuration supportGSDML file
Additional functionsConformance class C; Fast start-up (FSU); LLDP; MRP; PROFINET IRT; PROFIenergy; SNMP; Shared device; Web server
Power supply, functionElectronics and load
Power supply, connection typePlug
power supply, connection systemM12x1, A-coded according to EN 61076-2-101
Power supply, number of pins/wires5
Operational voltage range DC18 V...30 V
Nominal operating voltage DC24 V
Max. power supply4 A
Intern power consumption nominal operating voltageTyp. 80 mA
Dimensions L x W x H (cm)9.1 x 4 x 5

Industrial Applications

1. PROFINET Integration of a Valve Terminal

A machine with an PROFINET master needs to command a compatible Festo valve terminal through its I-Port interface. The CTEU-PN supplies the network connection using two D-coded M12 sockets and an electrically isolated 100 Mbit/s Ethernet interface. Its maximum 64-byte input and output address volumes define the listed capacity for configuring the terminal process-data exchange.

Problem Solved

The bus node translates between the PROFINET network connection and compatible I-Port equipment, providing a documented communication path for valve commands and the terminal's associated process information.

PROFINET I-Port equipment Isolated Ethernet

2. Diagnostic Access for a Pneumatic Station

A controller needs more than ordinary valve commands when investigating a station communication or supply problem. The CTEU-PN lists communication-error, undervoltage and system diagnostics, together with a web-server function. Local PS, X1 and X2 indicators show supply and I-Port module conditions, while NF and TP1/TP2 indicators expose network fault and port activity at the machine.

Problem Solved

Diagnostic services and local indicators give the control system and maintenance personnel documented ways to observe communication and supply conditions around the connected I-Port station.

System diagnostics Local LEDs Web server

3. Fast-Start Network Integration for a Machine Module

A modular machine needs its pneumatic station integrated into a PROFINET architecture that uses fast start-up. The CTEU-PN lists FSU, conformance class C and GSDML configuration support, providing documented functions for that network design. Its two M12 network sockets support the physical Ethernet connections, while the actual station restart sequence depends on the controller, configuration and connected equipment.