1. Short Air Commands for a Release Nozzle
A packaging station commands a small air nozzle to help release a component at a process step. The normally closed 3/2-way valve provides supply-and-exhaust routing, with direct actuation and specified 8.3 ms on/4.5 ms off component switching times. Its 200 l/min nominal flow characterizes the valve; nozzle pulse duration also depends on tubing, connected volume and the electrical command.
Problem Solved
Direct electrical actuation and documented switching times provide a defined valve response for a short air command, while the normally closed function supplies the required unactuated routing state.
3/2 normally closed
8.3 ms on / 4.5 ms off
200 l/min nominal
2. Electrical Commands to a Pneumatic Pilot Circuit
An automated fixture uses a downstream pneumatic control element and needs an electrical-to-pneumatic command stage. This direct-acting 3/2 valve switches its working path from a 24 V DC command and returns by mechanical spring. QS-6 supply, working and exhaust connections organize the valve station, while the two-pin plug defines the electrical connection.
Problem Solved
The valve converts an electrical sequence command into a pneumatic switching state, with direct actuation and mechanical spring reset providing the command stage for the downstream circuit.
Direct actuation
24 V DC
Mechanical spring reset
3. Restricted-Pressure Vacuum Path Switching
A handling circuit requires a small directional valve whose working paths can operate below atmospheric pressure. Festo permits reversible operation for this model within the restricted −0.9 to 1 bar pressure range, distinct from its ordinary −0.9 to 8 bar rating. The direct-acting design switches without a separate pilot-air pressure requirement, with QS-6 supply, working and exhaust connections providing the three pneumatic interfaces.
Problem Solved
Documented reversible low-pressure operation provides a valve basis for a vacuum-path circuit, while direct actuation avoids introducing a separate pneumatic pilot supply to switch that component.
−0.9 to 1 bar reversible
Direct-acting
Sub-base interface