Sale!

Festo 527464 Pressure Sensor, 0–10 bar, PNP NO, QS-6

Original price was: USD 293.28.Current price is: USD 252.20.

Piezoresistive threshold sensor with teach-in, QS-6 connection, three-pin M8 plug, ±0.5% FS accuracy and 2 ms switching times on a 15–30 V DC supply.

SKU Festo-527464 Category
Festo Pressure Sensors And Vacuum Sensors

Festo SDE5-D10-O-Q6-P-M8 Pressure Sensor

BrandFesto
Model IdentifierSDE5-D10-O-Q6-P-M8
Official Part Number527464

Technical Overview

The Festo SDE5-D10-O-Q6-P-M8 measures relative pressure from 0 to 10 bar using a piezoresistive sensing element. Its PNP normally open output implements a teach-in threshold with fixed 2% FS hysteresis and specified 2 ms switch-on and switch-off times. Accuracy is ±0.5% FS, with ±0.3% FS repetition accuracy under the manufacturer's conditions. A QS-6 pneumatic connection links the sensing line, while a three-pin A-coded M8 plug supplies 15–30 V DC power and the switching output. The 19 g sensor has a yellow switching LED, IP40 protection and Class 4 cleanroom suitability, with 0 to +50 °C ambient and media operation.

0 to 10 bar relative-pressure sensor with PNP normally open threshold output, teach-in, QS-6 pneumatic connection and three-pin M8 plug.

Key Features

  • Piezoresistive measurement of relative pressure from 0 to 10 bar
  • PNP normally open switching output
  • Threshold function with fixed 2% FS hysteresis
  • Teach-in adjustment across 0–100% threshold setting range
  • ±0.5% FS accuracy and ±0.3% FS repetition accuracy
  • 2 ms switch-on and 2 ms switch-off times
  • QS-6 pneumatic connection and three-pin A-coded M8 plug
  • 15–30 V DC supply and 100 mA maximum output current
  • 19 g product weight with yellow switching LED
  • IP40 protection, Class 4 cleanroom suitability and 0 to +50 °C ambient/media range

Provide a taught pressure-threshold signal through a PNP output with 2 ms switching times and a direct QS-6 sensing-line connection.

Technical Specification Matrix

ParameterValue
ApprovalRCM; c UL us - Recognised (Oil)
CE mark (see declaration of conformity)To EU EMC Directive; In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC; To UK RoHS instructions
Note on materialsRoHS compliant
Measured variableRelative pressure
Measurement methodPiezoresistive pressure sensor
Start value for pressure measuring range0 MPa; 0 bar; 0 psi
End value for pressure measuring range1 MPa; 10 bar; 145 psi
Overload pressure1.5 MPa; 15 bar; 217.5 psi
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible
Media temperature0 °C...50 °C
Ambient temperature0 °C...50 °C
Accuracy in ± % FS0.5 %FS
Repetition accuracy in ± %FS0.3 %FS
Temperature coefficient in ± %FS/K0.05 %FS/K
Switching outputPNP
Switching functionThreshold value with fixed hysteresis
Switching element functionN/O contact
Hysteresis in ± %FS2 %FS
Switch-on time2 ms
Switch-off time2 ms
Max. output current100 mA
Voltage drop1.8 V
Short circuit current ratingYes
Overload protectionYes
Operational voltage range DC15 V...30 V
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typePlug
Electrical connection 1, connector systemM8x1, A-coded, to EN 61076-2-104
Electrical connection 1, number of connections/cores3
Electrical connection 1, type of mountingSnap-locking; Screw-type lock; Not rotatable
Electrical connection 1, compatible type of mountingCompatible with latching lock; Compatible with rotatable screw-type lock
Material connector housingBrass, nickel-plated
Max. cable length30 M
Type of mountingWith accessories
Mounting positionAny
Pneumatic connectionQS-6
Physical Weight (kg)0.019
Material housingReinforced PA; Reinforced POM
Material sealing ringFluoro rubber; NBR
Switching status indicationYellow LED
Setting optionsTeach-in
Setting range threshold value0 %...100 %
Degree of protectionIP40
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Cleanroom suitability, measured according to ISO 14644-14Class 4 according to ISO 14644-1

Industrial Applications

1. Compressed-Air Branch Readiness

A machine needs a pressure-based input before starting a pneumatic sequence. The sensor measures relative pressure from 0 to 10 bar through its QS-6 connection and changes a PNP normally open output at the taught threshold. Fixed 2% FS hysteresis and 2 ms switch-on time characterize the sensor response, giving the controller a discrete pressure condition to use in its sequence logic.

Problem Solved

The taught threshold converts branch pressure into a controller input, providing pressure-condition feedback before the pneumatic sequence starts instead of relying solely on a valve command.

0–10 bar PNP NO threshold QS-6

2. Depressurization Sequence Feedback

After a pneumatic branch is commanded to exhaust, the controller needs to observe whether pressure has crossed a selected threshold. This sensor supplies a discrete switching result within its 0–10 bar relative-pressure range, with a specified 2 ms switch-off time. The pressure signal describes the monitored line condition rather than certifying that every connected chamber has reached zero pressure.

Problem Solved

Threshold switching gives the controller feedback as the monitored branch depressurizes, distinguishing a line still beyond the selected setting from one that has crossed it.

Relative pressure 2 ms switch-off Teach-in threshold

3. Regulated Branch Pressure-Loss Indication

A machine monitors a regulated air branch during an operating period and needs to detect a departure across a pressure threshold. The SDE5 supplies a PNP normally open output with fixed hysteresis, while a yellow LED shows its switching state locally. The controller can use that event to flag a changed branch condition without treating the sensor as a proportional pressure transmitter.

Problem Solved

A local pressure threshold makes a changed branch condition available to the control system, while the yellow LED gives maintenance staff visible switching information at the sensor.

PNP normally open Fixed hysteresis Yellow LED
Select your currency