| Product type | OD Precision evaluation unit; PNP input/output version |
| Compatible sensor heads | OD Precision; up to three heads, A/B/C; select head and setup for the intended measurement |
| Display | 4.4-inch LCD; adjustable digit count, display brightness and key illumination |
| Communication interfaces | RS-232C and USB |
| Control outputs | Five PNP control outputs via 50-pin I/O expansion connection; extension accessory required for field wiring |
| Control output ratings | PNP open collector; ≤100 mA at 24 V DC; residual voltage ≤1.8 V; configurable HI/LO and hysteresis |
| Alarm output | PNP open collector; ≤100 mA at 24 V DC; residual voltage ≤1.8 V; ON when sensor head cannot measure |
| Analog voltage output | ±10 V/F.S.; output impedance 100 Ω; minimum load 10 kΩ |
| Analog current output | 4–20 mA/F.S.; maximum load impedance 300 Ω |
| Analog channels | QA1, QA2 and QA3; voltage/current terminals shown separately in manufacturer connection diagram |
| Output source selection | Head measurement or calculated value; assign calculation to control and/or analog output |
| Calculation settings | Addition/subtraction with variables A, B, C, constant K or 0; selectable measurement-value signs and shifts |
| Constant K setting | −2999.9999 to +2999.9999 mm; stored in active bank |
| Shift/offset setting | Head A/B/C or calculated value; −2999.9999 to +2999.9999 mm; stored in active bank |
| Two-head thickness calculation | Known reference thickness K with head zeroing; K−A−B per manufacturer setup; align/calibrate both heads and keep target in both measuring ranges |
| Two-head anti-interference condition | Required for transparent, semi-transparent or very thin material; pulsed operation lengthens sampling timing per manual |
| Hold functions | Per-head or calculated-value hold; sample and peak modes; hold/reset inputs through I/O expansion cable |
| Bank input | 16 selectable banks; PNP input ON when connected to 12–24 V |
| Hold input | Measurement-value holding; PNP input ON at 12–24 V |
| Reset input | Zero reset for A/B/C or calculated value; PNP input ON at 12–24 V |
| Laser-off input | Laser shutoff for head A/B/C; PNP input ON at 12–24 V |
| Other settings | Filter/cutoff, memory copying, RS-232 settings and measurement display settings |
| Response/output timing | Manual lists 0.1 ms / 0.8 ms response and 10 kHz / 1.25 kHz output rates; establish actual head and configuration timing for the application |
| Temperature drift | ±0.01% F.S./°C; F.S. is the sensor measuring range |
| Power supply | 12–24 V DC ±10% |
| Current consumption | 350 mA at 24 V with three connected heads, including analog current output |
| Power/analog terminal board | Detachable; 1=24 V, 2=0 V; 3=QA3 mA, 4=GND; 5=QA2 mA, 6=GND; 7=QA1 mA; 8=QA3 V, 9=GND; 10=QA2 V, 11=GND; 12=QA1 V |
| RS-232C pin assignment | 2=RXD; 3=TXD; 5=GND; 1/4/6/7/8/9 not assigned |
| Mounting provisions | Panel mounting bracket provision; recommended window 173 × 102 mm; DIN rail mounting provision |
| Housing material | Polycarbonate chassis; nylon 66 terminal board |
| Protection class | III |
| IP rating | IP20 |
| Operating temperature | −10 to +45 °C, non-condensing |
| Storage temperature | −20 to +60 °C |
| Relative humidity | 35–85% RH for operation and storage |
| Vibration resistance | 10–55 Hz; double amplitude 1.5 mm; 2 hours on each X/Y/Z axis |
| Shock resistance | 20 G, 196 m/s² |
| Physical Weight (kg) | 0.55 |