$ 220.80
Phoenix Contact develops terminal blocks, power supplies, relays, connectors, signal conditioners, controllers & PLCs, I/O systems, Industrial Ethernet, controller system cabling, PCB terminal blocks & connectors, and surge suppression.
Item number | 2908060 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Product key | DK1212 |
GTIN | 4055626274584 |
Weight per piece (including packing) | 170 g |
Weight per piece (excluding packing) | 160 g |
Customs tariff number | 85437090 |
Country of origin | DE |
Product type | Output signal conditioner |
Product family | MACX Analog |
No. of channels | 1 |
Type | Ex i signal conditioners with SIL functional safety |
Configuration | DIP switches |
Functionality | |
Configuration | DIP switches |
Electrical isolation | 3-way isolation |
Signal transmission behavior | In = Out |
Step response (10-90%) | < 140 µs (for 4 mA … 20 mA step) |
Maximum temperature coefficient | 0.01 %/K |
Temperature coefficient, typical | ≤ 0.005 %/K |
Maximum transmission error | 0.1 % (of final value 20 mA) |
Transmission error, typical | ≤ 0.05 % (of final value 20 mA) |
Electrical isolation | |
Overvoltage category | II |
Pollution degree | 2 |
Electrical isolation Input/output IEC/EN 61010-1 | |
Standards/regulations | IEC/EN 61010-1 |
Rated insulation voltage | 300 Vrms |
Test voltage | 2.5 kV AC (50 Hz, 60 s) |
Insulation | Safe isolation |
Electrical isolation Input/power supply IEC/EN 61010-1 | |
Standards/regulations | IEC/EN 61010-1 |
Rated insulation voltage | 50 Vrms |
Test voltage | 1.5 kV AC (50 Hz, 60 s) |
Insulation | Basic insulation |
Electrical isolation Output/supply IEC/EN 61010-1 | |
Standards/regulations | IEC/EN 61010-1 |
Rated insulation voltage | 300 Vrms |
Test voltage | 2.5 kV AC (50 Hz, 60 s) |
Insulation | Safe isolation |
Electrical isolation Output/input IEC/EN 60079-11 | |
Standards/regulations | IEC/EN 60079-11 |
Rated insulation voltage | 375 VPP |
Electrical isolation Output/supply IEC/EN 60079-11 | |
Standards/regulations | IEC/EN 60079-11 |
Rated insulation voltage | 375 VPP |
Supply | |
Nominal supply voltage | 24 V DC -20 % … +25 % |
Supply voltage range | 19.2 V DC … 30 V DC |
Max. current consumption | < 45 mA (24 V DC / 20 mA) |
Power dissipation | < 0.8 W (24 V DC / 20 mA) |
Power consumption | ≤ 1.1 W (24 V DC / 20 mA) |
Signal: Current | |
Input signal | Current |
Current input signal | 0 mA … 20 mA (Function (short-circuit detection off)) |
0.2 mA … 20 mA (Function (short-circuit detection on)) | |
4 mA … 20 mA (Safety) | |
0 mA … 24 mA (Underload/overload range) | |
Input current | ≤ 30 mA |
Input impedance | > 1 MΩ (If there is a line fault) |
Line fault detection | > 0.2 mA (Response threshold of input current) |
Voltage drop | < 2.4 V (at 20 mA) |
Signal: Current | |
Output description | intrinsically safe |
Number of outputs | 1 |
Current output signal | 0 mA … 20 mA (Function (short-circuit detection off)) |
0.2 mA … 20 mA (Function (short-circuit detection on)) | |
4 mA … 20 mA (Safety) | |
0 mA … 24 mA (Underload/overload range) | |
Load | 100 Ω … 700 Ω (20 mA (short-circuit detection on)) |
100 Ω … 650 Ω (20.5 mA (short-circuit detection on)) | |
100 Ω … 500 Ω (24 mA (short-circuit detection on)) | |
0 Ω … 700 Ω (20 mA (short-circuit detection off)) | |
0 Ω … 650 Ω (20.5 mA (short-circuit detection off)) | |
0 Ω … 500 Ω (24 mA (short-circuit detection off)) | |
Output ripple | < 20 mVrms |
Non-load voltage | ≤ 27 V |
Line fault detection | > 10 kΩ (Line break) |
< 50 Ω (Short circuit) |
Connection method | Screw connection |
Stripping length | 7 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² … 2.5 mm² |
Conductor cross section flexible | 0.2 mm² … 2.5 mm² |
Conductor cross section AWG | 24 … 14 |
Tightening torque | 0.5 Nm … 0.6 Nm |
COMBICON connection | |
Max. diameter | 2 mm |
Ex installation (EPL) | Gc |
Div. 2 | |
Ex i circuits (EPL) | Ga |
Da | |
Ma | |
Div. 1 | |
Safety data | |
Max. internal inductance Li | negligible |
Max. internal capacitance Ci | negligible |
Max. output voltage Uo | 25.2 V |
Max. output current Io | 93 mA |
Max. output power Po | 586 mW |
Safety-related maximum voltage Um | 253 V AC |
125 V DC | |
IIA (simple circuit): Max. external inductivity Lo / Max. external capacitance Co | 10 mH / 2.9 µF |
IIB (simple circuit): Max. external inductivity Lo / Max. external capacitance Co | 4 mH / 817 nF |
IIC (simple circuit): Max. external inductivity Lo / Max. external capacitance Co | 2 mH / 104 nF |
IIA (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co | 10 mH / 587 nF, 1 mH / 627 nF, 500 µH / 717 nF, 200 µH / 907 nF, 100 µH / 1.1 µF |
IIB (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co | 4 mH / 367 nF, 1 mH / 427 nF, 500 µH / 507 nF, 200 µH / 657 nF, 100 µH / 817 nF |
IIC (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co | 2 mH / 46 nF, 1 mH / 60 nF, 500 µH / 77 nF, 200 µH / 104 nF |
Data communication (bypass) | |
HART function | Yes |
Protocols supported | HART-transparent |
Status display | Green LED (supply voltage) |
Width | 12.5 mm |
Height | 112.5 mm |
Depth | 113.7 mm |
Depth NS 35/7,5 | 114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715) |
Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V0 (Housing) |
Housing material | PA 6.6-FR |
Ambient conditions | |
Degree of protection | IP20 |
Ambient temperature (operation) | -40 °C … 70 °C (Any mounting position) |
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Permissible humidity (operation) | 5 % … 95 % (non-condensing) |
Altitude range (≤ 2000 m (Ex)) | |
Description | Ex applications |
Altitude | ≤ 2000 m (The technical data refers to altitudes ≤2000 m above mean sea level. For altitudes >2000 m above mean sea level, refer to the data sheet.) |
Ambient temperature (operation) | -40 °C … 70 °C |
Safety-related maximum voltage Um | 253 V AC |
125 V DC | |
Rated insulation voltage | 320 V (Power supply, input / output) |
Altitude range (≤ 3000 m (Ex)) | |
Description | Ex applications |
Height range | > 2000 m … 3000 m |
Ambient temperature (operation) | -40 °C … 60 °C |
Safety-related maximum voltage Um | 190 V AC |
110 V DC | |
Rated insulation voltage | 190 V (Power supply, input / output) |
Altitude range (≤ 4000 m (Ex)) | |
Description | Ex applications |
Height range | > 3000 m … 4000 m |
Ambient temperature (operation) | -40 °C … 55 °C |
Safety-related maximum voltage Um | 60 V AC |
60 V DC | |
Rated insulation voltage | 63 V (Power supply, input / output) |
Altitude range (≤ 5000 m (Ex)) | |
Description | Ex applications |
Height range | > 4000 m … 5000 m |
Ambient temperature (operation) | -40 °C … 45 °C |
Safety-related maximum voltage Um | 60 V AC |
60 V DC | |
Rated insulation voltage | 63 V (Power supply, input / output) |
Altitude range (≤ 2000 m) | |
Description | Non-Ex applications (EN 61010-1) |
Altitude | ≤ 2000 m (The technical data refers to altitudes ≤2000 m above mean sea level. For altitudes >2000 m above mean sea level, refer to the data sheet.) |
Ambient temperature (operation) | -40 °C … 70 °C |
Rated insulation voltage | 300 V (Power supply, input / output) |
Altitude range (≤ 3000 m) | |
Description | Non-Ex applications (EN 61010-1) |
Height range | > 2000 m … 3000 m |
Ambient temperature (operation) | -40 °C … 60 °C |
Rated insulation voltage | 150 V (Power supply, input / output) |
Altitude range (≤ 4000 m) | |
Description | Non-Ex applications (EN 61010-1) |
Height range | > 3000 m … 4000 m |
Ambient temperature (operation) | -40 °C … 55 °C |
Rated insulation voltage | 150 V (Power supply, input / output) |
Altitude range (≤ 5000 m) | |
Description | Non-Ex applications (EN 61010-1) |
Height range | > 4000 m … 5000 m |
Ambient temperature (operation) | -40 °C … 45 °C |
Rated insulation voltage | 150 V (Power supply, input / output) |
CE | |
Certificate | CE-compliant |
Note | and EN 61326 |
ATEX | |
Identification | I (M1) [Ex ia Ma] I |
II (1) G [Ex ia Ga] IIC | |
II (1) D [Ex ia Da] IIIC | |
II 3(1) G Ex ec [ia Ga] IIC T4 Gc | |
Certificate | BVS 20 ATEX E 004 X |
IECEx | |
Identification | [Ex ia Ma] I |
[Ex ia Ga] IIC | |
[Ex ia Da] IIIC | |
Ex ec [ia Ga] IIC T4 Gc | |
Certificate | IECEx BVS 20.0003X |
CCC / China-Ex | |
Identification | [Ex ia Ga] IIC |
[Ex ia Da] IIIC | |
Ex ec [ia Ga] IIC T4 Gc | |
Certificate | 2021122316114080 |
UL, USA/Canada | |
Identification | UL 61010 Listed |
Class I Div 2; IS for Class I, II, III Div 1 | |
Certificate | , C.D.-No 83104549 |
Shipbuilding approval | |
Certificate | DNV GL TAA00000AG |
Safety Integrity Level (SIL, IEC 61508) | |
Identification | 2 |
Systematic Capability | |
Identification | 3 |
INMETRO | |
Identification | [Ex ia Ma] I |
[Ex ia Ga] IIC | |
[Ex ia Da] IIIC | |
Ex ec [ia Ga] IIC T4 Gc | |
Certificate | DNV 21.0092 X |
Shipbuilding data | |
Temperature | B |
Humidity | B |
Vibration | A |
EMC | B |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
Electromagnetic compatibility | Conformance with EMC directive |
Noise immunity | EN 61000-6-2 |
Note | When being exposed to interference, there may be minimal deviations. |
Noise emission | |
Standards/regulations | EN 61000-6-4 |
Electrical isolation | 3-way isolation |
GB Standard | |
Standards/regulations | GB/T 3836.1 |
GB/T 3836.3 | |
GB/T 3836.4 |
Mounting type | DIN rail mounting |
Weight | 0.170 kg |
---|---|
Dimensions | 11.45 × 1.25 × 11.25 cm |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penang
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,