Phoenix Contact MINI MCR-SL-UI-UI-NC Signal Conditioner

$ 131.33

Compact Phoenix Contact MINI MCR-SL-UI-UI-NC ensures safe 3-way isolation, flexible signal conversion, and reliable performance in automation systems.

Product Description

Phoenix Contact MINI MCR-SL-UI-UI-NC Signal Conditioner – Reliable 3-Way Isolation

The Phoenix Contact MINI MCR-SL-UI-UI-NC signal conditioner is a compact isolating amplifier designed to safely separate and process analog signals. Its highly flexible DIP switch configuration supports multiple signal ranges, enabling smooth adaptation to diverse automation tasks. With a width of only 6.2 mm, it optimizes valuable space in control panels while providing dependable electrical isolation. Low power consumption, integrated transient protection, and a rugged build make this model a trusted choice for stable and interference-free signal handling in industrial environments.

Engineered for precision, the Phoenix Contact MINI MCR-SL-UI-UI-NC ensures electrical separation between input, output, and supply to protect systems from cross-interference. It accommodates both current and voltage signals, allowing easy integration with sensors, controllers, and monitoring equipment. The slim DIN-rail design simplifies installation in dense cabinets, while TBUS power distribution supports efficient wiring for multiple modules. By improving signal accuracy and reliability, it helps reduce downtime, extend equipment life, and streamline maintenance. This makes it especially valuable in process automation, machine control, and building management applications where consistent performance is essential.

Why Phoenix Contact MINI MCR-SL-UI-UI-NC?
The Phoenix Contact MINI MCR-SL-UI-UI-NC is more than just a signal conditioner—it’s a compact powerhouse for ensuring precision in automation. With flexible input and output ranges, space-saving design, and robust isolation, it delivers dependable signal quality even in demanding industrial environments. Engineers choose it for its balance of versatility, reliability, and effortless integration.

What Problem Does It Solve?
Industrial systems often struggle with noisy signals, mismatched inputs, and safety risks caused by poor isolation. The MINI MCR-SL-UI-UI-NC solves these issues by cleanly separating, converting, and stabilizing analog signals. By doing so, it prevents cross-interference, protects equipment, and ensures consistent measurement accuracy—eliminating hidden downtime risks and supporting seamless system performance.

 


Key Features & Specifications – Phoenix Contact MINI MCR-SL-UI-UI-NC (Article No. 2864150)

Feature Details Benefit
Isolation 3-way isolation (input/output/supply) Prevents interference and enhances system safety
Input Signal Range 0–10 V, 0–5 V, 1–5 V, 2–10 V, 0–20 mA, 4–20 mA Versatile support for multiple signal types
Output Signal Range Configurable voltage/current outputs Flexible adaptation to controllers and PLCs
Configuration DIP switches, up to 36 combinations Quick setup and customization without software
Power Supply 24 V DC (19.2–30 V DC range) Compatible with standard industrial supplies
Power Consumption < 200 mW (voltage output) / < 450 mW (current output) Low energy usage reduces operating costs
Response Time ~3.2 ms Fast signal processing ensures accuracy
Width 6.2 mm Space-saving design for dense control panels
Operating Temperature -20 °C … +65 °C Reliable performance in harsh conditions
Mounting DIN rail EN 60715 Simple installation in standard control cabinets
Approvals CE, UL, DNV GL, UKCA Certified for global industrial use

Download Phoenix Contact MINI MCR-SL-UI-UI-NC (2864150) Datasheet

 


Commercial Information – Phoenix Contact MINI MCR-SL-UI-UI-NC (Article No. 2864150)

Commercial Data Details
GTIN Number 4017918956615
Customs Tariff Number 85437090
Weight 77 g (without packaging) / 87.2 g (with packaging)
Country of Origin Germany

 


The Applications

1. Precision Process Control in Noisy Environments

In large industrial plants, analog signals often travel through environments filled with electromagnetic interference and ground loops. Without proper isolation, these disturbances can distort critical measurements like flow, pressure, or temperature. The MINI MCR-SL-UI-UI-NC addresses this by separating input, output, and power supply, delivering a clean, reliable signal to the control system. Operators benefit from accurate data that improves process stability, reduces false alarms, and minimizes downtime caused by inaccurate readings. By keeping analog signals precise, engineers can maintain tighter control of complex processes and ensure safer, more efficient plant operations.

2. Bridging Modern Sensors with Legacy Equipment

Older automation systems often accept only current loop inputs, while modern sensors may provide voltage outputs. This mismatch can make upgrades costly and complex. The MINI MCR-SL-UI-UI-NC simplifies integration by converting voltage signals into standard current ranges, ensuring compatibility with legacy controllers. Its flexible DIP switch configuration allows technicians to set the required ranges without software tools, making commissioning quick and straightforward. This reduces the need for extensive rewiring or equipment replacement, saving costs while extending the life of existing infrastructure. Facilities benefit from modernization without losing reliability or disrupting established workflows.

3. Splitting Signals for Multiple Destinations

In many production lines, one measurement may need to be sent to both monitoring software and a safety system. Directly wiring the same sensor output can cause ground loops or distort the signal. The MINI MCR-SL-UI-UI-NC solves this by isolating and conditioning the signal before delivering clean outputs to multiple devices. Each system receives accurate data without interference, maintaining consistency across all monitoring points. This capability not only protects connected equipment but also enhances safety by ensuring alarms and process displays react to the same precise information. The result is greater flexibility and reliability in plant supervision.

4. Protecting Sensitive Systems in Medical and Lab Use

In laboratories and medical environments, sensitive equipment must be shielded from electrical interference and leakage currents. Even small voltage differences can cause inaccurate readings or safety concerns. The MINI MCR-SL-UI-UI-NC acts as a protective barrier, providing galvanic isolation between sensors and monitoring devices. This ensures measurements such as temperature or flow in bioreactors remain stable and trustworthy. At the same time, it prevents harmful currents from reaching patient-connected or delicate instruments. By maintaining both safety and precision, the device supports environments where accuracy and reliability are essential, whether in clinical research, healthcare diagnostics, or controlled laboratory processes.

 


Related Products & Accessories – Phoenix Contact MINI MCR-SL-UI-UI-NC

Category Model Name Part Number Description Benefit
DIN Rail Bus Connector ME 6,2 TBUS-2 1,5/5-ST-3,81 GY 2695439 Five-position bus connector for bridging supply voltage across multiple MINI Analog modules. Enables quick, tool-free power distribution to multiple devices on a DIN rail.
ME 6,2 TBUS-2 1,5/5-ST-3,81 GN 2869728 Universal TBUS connector with gold-plated contacts for DIN rail mounting. Ensures reliable power connection and long service life.
Module Carrier TC-D37SUB-AIO16-M-PS-UNI 2902934 Carrier for connecting up to 16 MINI Analog modules to digital/analog I/O cards with HART multiplexer. Simplifies integration in large-scale automation setups.
TC-D37SUB-ADIO16-M-P-UNI 2902933 Carrier for connecting 16 MINI Analog modules with 37-pos. D-SUB connection. Provides efficient wiring and reduces setup time.
Transparent Cover MINI MCR DKL 2308111 Fold-up protective cover with extra space for labeling. Protects modules and improves identification in dense panels.
Marking Label MINI MCR-DKL-LABEL 2810272 Extended labeling strip designed for use with MINI MCR-DKL cover. Enhances organization and simplifies maintenance.
Power Terminal Block MINI MCR-SL-PTB 2864134 Terminal block for distributing up to 2 A across multiple MINI Analog modules. Provides safe, centralized power distribution.
Power Supply QUINT4-SYS-PS/1AC/24DC/2.5/SC 2904614 QUINT POWER switched-mode DIN rail power supply, 24 V DC output. Robust and efficient supply with protective coating for demanding environments.
Screwdriver Tool SZS 0,6X3,5 1205053 Insulated screwdriver and actuation tool for terminal blocks and module wiring. Safe and reliable tool for installation and service.

 


Contact Us

For expert guidance before placing your order.
Warranty – 1-year warranty for your peace of mind.
Global Shipping – We ship worldwide with secure packaging and reliable delivery.
Technical Support – Contact us for professional after-sales technical assistance.

Select your currency