Phoenix Contact ELR H5-ES-SC-24DC/500AC-9 Motor Starter

$ 213.67

Phoenix Contact ELR H5-ES-SC-24DC/500AC-9 hybrid motor starter, 9A, 24V DC input, reversing, and emergency stop. Compact, safe, and efficient motor control.

Product Description

Phoenix Contact ELR H5-ES-SC-24DC/500AC-9 Hybrid Motor Starter – Compact Safety and Reliability

The Phoenix Contact ELR H5-ES-SC-24DC/500AC-9 Hybrid Motor Starter is a space-saving solution designed for controlling and reversing three-phase AC motors up to 550 V AC and 9 A. With only 22.5 mm width, it simplifies wiring and optimizes cabinet space. The integrated safety stop and compliance with leading safety standards make it ideal for applications where reliability is critical. By using hybrid switching technology, this motor starter reduces wear, extends service life, and ensures dependable performance in demanding industrial automation environments.

This hybrid motor starter combines multiple functions—reversing, protection, and emergency shutdown—into a single compact unit, eliminating the need for several separate devices. Its advanced design reduces maintenance requirements by minimizing contact wear while providing built-in surge and polarity protection. Quick DIN rail installation makes integration fast and efficient, helping engineers streamline control cabinet layouts. With approvals for international use, it fits a wide range of industries from machinery and conveyors to process automation. Users gain increased uptime, reduced installation effort, and improved motor safety, ensuring long-term operational efficiency.

Why Phoenix Contact ELR H5-ES-SC-24DC/500AC-9?
Because it packs motor control, reversing, and emergency safety into one compact module, reducing wiring time and cabinet space. Its hybrid technology ensures low-wear switching, extending system life while giving engineers peace of mind in critical automation environments. It’s the ideal balance of safety, performance, and efficiency in one device.

What problem does it solve?
It eliminates the need for multiple motor starters, contactors, and safety relays, simplifying installation and reducing maintenance. By integrating reversing functionality, overload protection, and emergency stop into a single hybrid unit, it solves space limitations, prevents costly downtime, and provides reliable safety compliance for modern industrial systems.

 


Key Features & Specifications – Phoenix Contact ELR H5-ES-SC-24DC/500AC-9 : 2900561

Feature Details Benefit
Rated Operating Voltage Up to 500 V AC (3-phase) Compatible with a wide range of motor systems
Rated Control Voltage 24 V DC (19.2 – 30 V DC range) Reliable low-voltage control input
Rated Current 9 A (AC-51) / 6.5 A (AC-53a) Suitable for small to medium motor applications
Safety Certifications SIL 3, PL e (ISO 13849) Meets high safety standards for emergency stop and safe shutdown
Switching Technology Hybrid, ≤2 Hz frequency Low-wear switching for longer service life
Protection Functions Surge & reverse polarity protection Improved system reliability and reduced risk of damage
Width 22.5 mm Saves cabinet space with compact form factor
Mounting DIN rail Quick installation and modular integration
Operating Temperature -25 °C to +70 °C Suitable for harsh industrial environments
Approvals UL, ATEX, IEC, EAC, CCC Ensures compliance for global applications

Download Phoenix Contact ELR H5-ES-SC-24DC/500AC-9 (2900561) Datasheet

 


Commercial Information – Phoenix Contact ELR H5-ES-SC-24DC/500AC-9 : 2900561

Commercial Data Details
GTIN Number 4046356527842
Tariff Number 85371098
Weight (Net) 217.18 g
Weight (Gross) 311.05 g
Country of Origin Germany (DE)

 


The Applications of Phoenix Contact ELR H5-ES-SC-24DC/500AC-9

1. Precision Conveyor Control in Packaging Lines
Modern packaging plants rely on conveyors that start, stop, and reverse frequently to handle varying product flows. The hybrid motor starter enables smooth reversing in a single unit while its emergency stop ensures immediate shutdown during jams. Low-wear switching extends motor life despite continuous cycles, and its compact 22.5 mm width saves control panel space. By simplifying wiring and reducing heat buildup, it helps keep conveyors reliable, energy-efficient, and safe in fast-paced production environments where downtime is costly.

2. Automated Shuttle Lifts in Warehousing
Warehouse shuttle lifts transport goods between different storage levels and require reliable forward/reverse motor operation. The ELR hybrid starter integrates reversing capability and overload protection into one compact device, eliminating multiple components. When a fault or safety trigger occurs, the built-in emergency stop immediately disconnects the motor, protecting workers and machinery. Hybrid switching technology reduces wear from constant lifting cycles, while quick DIN rail installation simplifies panel design. This ensures efficient vertical handling, minimal downtime, and long service life in automated logistics systems.

3. Pumping Stations with Backflow Protection
Industrial pumping stations often face blockages or fluid backflow, requiring controlled reversing of pump motors. The hybrid motor starter provides reliable forward and reverse operation with overload detection to protect against excessive current draw. Integrated surge and polarity safeguards prevent damage from unstable supply conditions. Emergency shutdown ensures immediate response if the system reaches unsafe conditions. Compact housing allows multiple units to be mounted side by side, saving cabinet space. This design improves pump reliability, reduces maintenance needs, and provides stable, safe operation for critical water treatment and chemical processing systems.

4. Sorting Machines in Material Handling
High-speed sorting machines in logistics and mail distribution demand frequent motor reversals to direct items to different paths. The ELR H5 hybrid starter enables precise direction control and incorporates a safe-stop function to quickly halt operation during errors. Its hybrid switching technology withstands constant start/stop demands without heavy wear, improving uptime. With diagnostic signaling, abnormal motor behavior can be detected early, reducing unplanned downtime. The narrow design conserves cabinet space, allowing more starters per system. This leads to faster installation, reduced complexity, and higher reliability in environments where speed and accuracy are essential.

 


Related Products & Accessories – Phoenix Contact ELR H5-ES-SC-24DC/500AC-9

Category Model Part Number Benefit
Loop Bridge (2 modules) BRIDGE-2 2900746 Enables quick parallel wiring of two modules
Loop Bridge (3 modules) BRIDGE-3 2900747 Simplifies connection of three starters in series
Loop Bridge (4 modules) BRIDGE-4 2900748 Reduces wiring time for larger assemblies
Loop Bridge (5 modules) BRIDGE-5 2900749 Efficient linking for medium control systems
Extended Loop Bridge (2 modules) BRIDGE-2-1M 2901542 Provides flexibility for spaced-out DIN rail layouts
Extended Loop Bridge (3 modules) BRIDGE-3-1M 2901655 Easy wiring when modules are not directly adjacent
Extended Loop Bridge (4 modules) BRIDGE-4-1M 2901658 Ideal for staggered panel installations
Extended Loop Bridge (5 modules) BRIDGE-5-1M 2901544 Supports flexible wiring in large cabinets
Plastic Label (Card) US-EMLP (15×5) 0828790 Allows clear identification of modules
Plastic Label (Sheet) UC-EMLP (15×5) 0819301 Provides durable marking for industrial panels

 


Contact Us

For expert guidance before placing your order.
Warranty – 1-year warranty for your peace of mind.
Global Shipping – We ship worldwide with secure packaging and reliable delivery.
Technical Support – Contact us for professional after-sales technical assistance.

Select your currency