SICK 1018810 C40E-1203CB010 C4000 Advanced Light Curtain Receiver

USD 3,117.40

C40E-1203CB010 is a 1,200 mm, 30 mm-resolution C4000 Advanced receiver with two PNP OSSDs, CDS configuration, blanking and optical synchronization.

SKU SICK-1018810 Category
SICK Safety Light Curtains

SICK C40E-1203CB010 C4000 Advanced Light Curtain Receiver

BrandSICK
Model IdentifierC40E-1203CB010
Official Part Number1018810

Technical Overview

The SICK C40E-1203CB010 is a C4000 Advanced safety light-curtain receiver for a matched optical system with a 1,200 mm protective field and 30 mm resolution. Two PNP semiconductor OSSDs provide the safety outputs, each rated up to 500 mA and monitored for short circuits and cross circuits. Response is 13 ms without beam coding, blanking or cascaded systems; configuration changes require the applicable response time. PC-based CDS configuration uses a four-pin M8 female connection and supports restart interlock, external device monitoring, beam coding and blanking. The 24 V DC receiver uses an extruded-aluminum housing and seven-segment display, with IP65 when plug connections are closed and operation from 0 to +55 °C.

C4000 Advanced receiver with 1,200 mm protective field, 30 mm resolution, two PNP OSSDs, CDS configuration and optical synchronization; matched sender required.

Key Features

  • C4000 Advanced receiver; matched sender and validated control integration required
  • 1,200 mm protective-field height; 30 mm resolution
  • Two PNP semiconductor OSSDs; each ≤500 mA; short-circuit protected and cross-circuit monitored
  • 13 ms response without beam coding, blanking or cascaded systems
  • 19 m guaranteed /21 m typical system reach for 30 mm resolution; match range setting to actual field width
  • PC configuration with CDS; M8 four-pin female configuration connector
  • Restart interlock, EDM, beam coding and fixed/floating blanking; configure and validate for the application
  • 24 V DC nominal, 19.2–28.8 V; ≤10% ripple within supply limits
  • Seven-segment display; extruded-aluminum housing; IP65 with plug connections closed
  • Operation 0 to +55 °C; Type 4, SIL 3, category 4 and PL e system ratings

Evaluate a matched C4000 protective field and provide two monitored PNP safety outputs, with configurable restart, feedback monitoring and guarded blanking.

Technical Specification Matrix

ParameterValue
System partC4000 Advanced light-curtain receiver; matched sender and complete safety-control integration required
Manufacturer datasheet familyC4000 Advanced
Application environmentNormal industrial environment
Protective field height1,200 mm
Resolution30 mm
Scanning rangeExact datasheet: 21 m; system manual for 20/30/40 mm resolution: 19 m guaranteed and 21 m typical; typical maximum has reduced optical reserve
Range configurationFactory setting 0–6 m; match configuration to actual protective-field width
SynchronizationOptical; no separate synchronization connection
Wavelength850 nm
System safety ratingsType 4, IEC 61496-1; SIL 3, IEC 61508; category 4 and PL e, EN ISO 13849; achieved performance depends on the complete validated system
Mission time20 years, EN ISO 13849
System safe stateAt least one OSSD in the OFF state on a fault
Beam codingUncoded, code 1 or code 2; neighboring systems use different codes; sender and receiver of one system use matching coding; coding increases system response time and changes required minimum distance
Protective operationAvailable within a matched sender/receiver system
Restart interlock and EDMRestart interlock available, external at delivery; EDM available, deactivated at delivery
BlankingFixed and floating blanking available, deactivated at delivery; blanked areas require separate risk assessment and appropriate guarding
Functions with UE402Bypass, operating-mode switching and PSDI in a suitable complete system with UE402
System connectionStraight; DIN 43651 M26 plug, 11 contacts plus FE, shown in the manufacturer drawing
Connection conductor cross-section0.75 mm² reference
Permitted cable length50 m depending on load, power supply and conductor cross-section; installation-specific limits apply
DisplaySeven-segment display
Power supply24 V DC nominal; 19.2–28.8 V; external supply must buffer 20 ms mains interruptions to EN 60204-1
Residual ripple≤10%, within supply-voltage limits
Protection classIII, IEC 61140
Housing materialExtruded aluminum profile
Housing cross-section48 × 40 mm; partial profile size
IP ratingIP65, EN 60529; all plug connections closed
Operating temperature0 to +55 °C
Storage temperature−25 to +70 °C
Air humidity15–95%, non-condensing
Vibration resistance5 g, 10–55 Hz; EN 60068-2-6
Shock resistance10 g, 16 ms; EN 60068-2-27
Documented relay integrationManufacturer example uses C4000 Advanced with UE402, contactors, restart interlock and EDM; complete installation-specific configuration required
Response time13 ms without beam coding, without blanking and without cascaded systems; use applicable operating-instruction timing for other configurations
OSSD outputsTwo PNP semiconductors; short-circuit protected and cross-circuit monitored for −30 to +30 V
OSSD current capacity≤500 mA per OSSD
OSSD HIGH voltageNominal 24 V DC; supply minus 2.25 V to supply
OSSD LOW voltage≤2 V DC
ConfigurationPC with CDS, Configuration and Diagnostic Software
Configuration connectionM8 four-pin female connector
EFISafe SICK device communication via EFI
Physical Weight (kg)2.56
Dimensions L x W x H (cm)132.9 x 4.8 x 4.0

Industrial Applications

1. Evaluating access to a machine opening

A machine designer can pair this receiver with a compatible sender across a 1,200 mm access field and connect its two PNP OSSDs to the validated stopping circuit. The 30 mm resolution and installed protective placement determine the access arrangement. Commissioning calculates minimum distance using the complete stopping time and the applicable configuration-specific response, then verifies field coverage and restart behavior.

Problem Solved

Optical field evaluation gives the safety-control circuit a monitored access condition for initiating the engineered stopping response when an intrusion interrupts the matched protective field.

Access evaluation Two OSSDs Matched light curtain

2. Supervising contactor feedback before restart

A stopping circuit can use the receiver’s external device monitoring and restart-interlock functions with correctly wired contactor feedback and the intended reset arrangement. The manufacturer’s UE402 example illustrates feedback-supervised control integration. The design configures the required functions and validates contactor release, reset operation and the resulting OSSD behavior before the machine sequence resumes.

Problem Solved

Feedback supervision helps the configured safety-control design assess external contactor behavior before restart, reducing the chance that an incorrect external-device state permits the intended machine sequence.

Contactor feedback Restart interlock EDM

3. Accommodating a fixed obstruction in an Advanced field

A machine design with a necessary fixed obstruction can pair this Advanced receiver with a compatible sender and configure fixed blanking. The designer establishes the blanked area and provides mechanical protection or other appropriate guarding against access through it. Commissioning validates the remaining field, effective resolution and configuration-specific response with the object present and after any change.

Problem Solved

Configured blanking allows a necessary obstruction within an engineered protective arrangement, while supplementary guarding prevents the excluded optical area from becoming an unprotected access route.

Fixed obstruction Advanced receiver Guarded blanking
Select your currency