SICK 6025115 i200-M0413 Lock Power-to-Release Safety Switch

SICK 6025115 i200-M0413 Lock Power-to-Release Safety Switch

USD 284.70

i200-M0413 Lock provides power-to-release guard locking, two positive-action NC lock contacts, two NC/one NO door contacts and a 20.4–26.4 V DC solenoid.

SKU: SICK-6025115 Category:
SICK Safety Switches

SICK i200-M0413 Lock Power-to-Release Safety Locking Switch

BrandSICK
Model Identifieri200-M0413 Lock
Official Part Number6025115

Technical Overview

The SICK i200-M0413 Lock is an electromechanical guard-locking switch using the power-to-release principle. It provides two positive-action normally closed contacts for locking monitoring and two positive-action normally closed plus one normally open contact for door monitoring. Stated locking force FZh is 2,000 N; maximum force is 2,600 N with the supplied fixing screws and 1,950 N otherwise. The solenoid operates at 20.4–26.4 V DC with power consumption up to 7 W. Three actuation directions, three M20 cable entries and LED status indication support installation. The IP65 glass-fiber-reinforced polyester device requires individual diagnostic wiring and external safety-related fault detection; a compatible actuator is ordered separately.

Power-to-release electromechanical safety locking switch with separate locking/door contacts, 2,000 N FZh and 20.4–26.4 V DC solenoid; actuator not supplied.

Key Features

  • Electromechanical Type 2 guard-locking switch; low actuator coding level
  • Power-to-release locking principle
  • Two positive-action NC locking-monitoring contacts
  • Two positive-action NC door contacts plus one NO door contact
  • FZh 2,000 N; Fmax 2,600 N with supplied fixing screws, otherwise 1,950 N
  • Solenoid 20.4–26.4 V DC; ≤7 W; 100% solenoid duty
  • Three actuation directions; approach speed ≤10 m/min; actuation frequency ≤3,600/h
  • Three M20 cable entries; 0.34–1.5 mm² conductors; LED status indication
  • Individual wiring with diagnostics; fault detection provided by external safety-related logic
  • IP65 glass-fiber-reinforced polyester housing; −20 to +60 °C; actuator not supplied

Combine physical guard locking with separate door and locking-status contacts for an individually wired, externally monitored safety-control arrangement.

Technical Specification Matrix

ParameterValue
Sensor principleElectromechanical
Locking principlePower to release
Locking-monitoring contactsTwo positive-action NC contacts; no NO contacts
Door-monitoring contactsTwo positive-action NC contacts plus one NO contact; no additional ordinary NC contact
Switching element41; separate LM locking-monitoring and DM door-monitoring contacts as shown in exact manufacturer diagram
Locking force FZh2,000 N; EN ISO 14119
Maximum locking force Fmax2,600 N only with supplied fixing screws; otherwise 1,950 N; EN ISO 14119
Retaining force≤30 N
Actuation frequency≤3,600 per hour
Actuation directions3
Approach speed≤10 m/min
B10d2 ×10⁶ switching cycles at small load
Device typeType 2; EN ISO 14119
Actuator coding levelLow coding level; EN ISO 14119
Fault detectionNo internal fault detection or internally assumed safe state on a fault; connected safety-related logic performs fault detection
Safe series connectionNone; individual wiring only, with diagnostics
ConnectionThree M20 cable-gland entries
Conductor cross-section0.34–1.5 mm²
IndicationLEDs; status display
Switching principleSlow-action switching element
Utilization categoryAC-15 / DC-13; IEC 60947-5-1
Rated operating current3 A at 240 V AC; 3 A at 24 V DC
Rated insulation voltage Ui500 V
Rated impulse withstand voltage Uimp2,500 V
Output typeElectromechanical contacts
Power consumption≤7 W
Short-circuit protection3 A gG
Switching voltage≥5 V DC
Switching current reference5 mA at 5 V DC
Solenoid supply20.4–26.4 V DC
Solenoid duty100%
Housing materialGlass-fiber-reinforced polyester
Mechanical life1 ×10⁶ switching cycles
IP ratingIP65
Operating temperature−20 to +60 °C
Storage temperature−20 to +60 °C
Actuator supplyActuator is not included; select a compatible actuator separately
Physical Weight (kg)0.55

Industrial Applications

1. Holding a guard through an engineered stopping interval

A machine designer can use the power-to-release lock to retain a movable guard while external safety logic manages the machine’s stopping interval and release permission. The solenoid is energized only when the validated sequence permits unlocking. Installation establishes a compatible actuator and fixing arrangement, observing the 2,000 N FZh and the fixing-screw condition on maximum locking force.

Problem Solved

Physical guard retention gives the engineered control sequence a means to delay access until its release condition is satisfied, using externally established stopping and unlocking logic.

Guard retention Power to release Controlled unlocking

2. Evaluating guard-door position before a machine cycle

A safety-control design can individually wire the two positive-action NC door-monitoring contacts into its external diagnostic logic and use the additional NO contact for the intended indication. A compatible actuator follows guard movement within the documented approach-speed and actuation limits. Commissioning validates door-position transitions and the overall machine-start condition, with fault detection supplied by the connected safety-related logic.

Problem Solved

Door-position contacts give the external control design a guard-state reference before a machine cycle, helping distinguish the intended closed condition from actuator withdrawal within the validated installation.

Door-state evaluation Positive-action contacts Individual wiring

3. Distinguishing a closed guard from a confirmed locked guard

External diagnostic logic can evaluate the separate locking-monitoring and door-monitoring contacts during a controlled lock/unlock sequence. The exact switching-element-41 diagram distinguishes inserted-and-locked, inserted-and-unlocked and actuator-removed states. Commissioning checks these transitions against the installed wiring and actuator arrangement, and uses the LED status indication as a local maintenance reference while the external logic performs fault detection.

Problem Solved

Separate door and locking observations help external diagnostics distinguish guard closure from confirmed locking, providing a clearer reference when investigating a failed lock or unlock sequence.

Lock-state feedback Door/lock distinction External diagnostics