SICK 1086327 IME08-04BNSZT0S NPN Inductive Sensor

USD 70.72

M8 quasi-flush inductive sensor with 4 mm nominal range, 3.24 mm assured range, NPN normally-open output, 500 Hz and M8 three-pin male connector.

SKU SICK-1086327 Category
SICK IME

SICK IME08-04BNSZT0S NPN Inductive Sensor

BrandSICK
Model IdentifierIME08-04BNSZT0S
Official Part Number1086327

Technical Overview

The SICK IME08-04BNSZT0S is an M8 × 1 inductive proximity sensor for quasi-flush installation. It provides 4 mm nominal sensing range and 3.24 mm assured range, with a normally-open NPN output in a DC three-wire circuit. The 500 Hz switching rating and continuous output current up to 200 mA support connection to external machine logic. An M8 three-pin male connector connects the 10–30 V DC device. Nickel-plated brass housing and a PA66 sensing face provide IP67 protection, with both operating and storage temperatures from −25 to +75 °C. Two nickel-plated brass mounting nuts are supplied. Installation uses the documented quasi-flush clearances, material reduction factors and maximum 5 Nm tightening torque.

Quasi-flush M8 inductive sensor with 4 mm nominal range, NPN normally-open output, 500 Hz and M8 three-pin male connector.

Key Features

  • Standard M8 × 1 metric housing for quasi-flush installation
  • 4 mm nominal sensing range; 3.24 mm assured range
  • Quadruple sensing range specified by manufacturer
  • NPN normally-open output; DC three-wire circuit
  • 500 Hz switching; continuous output current ≤200 mA
  • M8 three-pin male connector
  • 10–30 V DC; voltage drop ≤2 V at maximum output current
  • Short-circuit and power-up pulse protection
  • Nickel-plated brass housing; PA66 sensing face; IP67
  • Two nickel-plated brass nuts; −25 to +75 °C operation and storage

Provide a 4 mm nominal metal-target sensing gap in an M8 quasi-flush installation, with NPN transitions for external machine logic.

Technical Specification Matrix

ParameterValue
Functional principleInductive proximity sensing
Housing designStandard metric cylindrical threaded design
Mounting threadM8 × 1
Nominal body diameter8 mm
InstallationQuasi-flush
Nominal sensing range Sn4 mm
Assured sensing range Sa3.24 mm
Special featureQuadruple sensing range
Switching outputNPN
Output functionNormally open (NO)
Electrical wiringDC three-wire
Switching frequency500 Hz
ConnectionM8 three-pin male connector
Conductor functionsCD-002: 1 BN=L+; 4 BK=NO output; 3 BU=M
Power supply10–30 V DC
Ripple≤10%
Voltage drop≤2 V at maximum continuous current
Time delay before availability≤50 ms
Hysteresis1–15%
Reproducibility≤5% of Sr with constant supply voltage and ambient temperature
Temperature drift of Sr±10%
Continuous current≤200 mA
No-load current≤10 mA
Protective functionsShort-circuit protection; power-up pulse protection
Housing materialNickel-plated brass
Sensing-face materialPA66 plastic
Housing length50 mm
Thread length34 mm
Tightening torque≤5 Nm
Items suppliedTwo nickel-plated brass mounting nuts; 13 mm across flats
IndicationDisplay LED
IP ratingIP67, EN 60529
Operating temperature−25 to +75 °C
Storage temperature−25 to +75 °C
Shock resistance30 g, 11 ms
Vibration resistance10–55 Hz, 1 mm
EMCEN 60947-5-2
Material reduction factorsReference values which may vary: St37 steel 1; V2A/304 stainless steel approximately 0.75; aluminum approximately 0.46; copper approximately 0.42; brass approximately 0.56
Installation clearancesManufacturer diagram keys A=4 mm; B=20 mm; C=8 mm; D=12 mm; E=1 mm; F=30 mm
UL fileNRKH.E181493
MTTFD1,735 years
DCavg0%
Mission time20 years

Industrial Applications

1. Confirming a metal clamp at its seated position

An assembly fixture can place a metal clamp target close to the quasi-flush sensing face at its intended seated position. The normally-open NPN output provides a reference to external sequence logic. Setup establishes the target gap using the 4 mm nominal and 3.24 mm assured ranges, actual material and geometry, and the specified quasi-flush installation clearances.

Problem Solved

A discrete seated-target reference gives external sequence logic a clamp-position condition, helping coordinate a dependent assembly operation when the expected metal target reaches the sensor.

Clamp position Quasi-flush M8 NPN output

2. Counting metal tabs on a repeating mechanism

A repeating mechanism can move separated metal tabs past the M8 sensing face and deliver NPN transitions to external counting electronics. The 500 Hz rating provides a basis for assessing tab-passage frequency and spacing. Installation maintains the commissioned gap and the documented quasi-flush clearances while accounting for target material and shape along the motion path.

Problem Solved

Repeated metal-target transitions give external counting electronics cycle or passage events, helping track mechanism movement through a compact stationary sensing point beside the tabs.

Metal-tab count 500 Hz External counter

3. Monitoring metal stock at a feeder reference

A feeder can position the sensor beside a reference location normally occupied by metal stock. The normally-open output changes when material leaves that region, and external monitoring times the absence against the expected feed sequence. The commissioned gap reflects the actual stock material and section, using the assured range and approximate reduction factors as setup references.

Problem Solved

A sustained target-absence condition supplies external feed monitoring with a stock-continuity reference, helping identify missing metal at the selected location before the next process step.

Stock continuity External timing Metal sensing