Technical Overview

The SICK AFM60A-BBNB018x12 is a PROFINET multiturn absolute encoder with 262,144 steps per revolution and 4,096 revolutions, corresponding to 18-bit singleturn and 12-bit multiturn resolution. Encoder profile V4.1 class 3 provides configurable steps, revolutions, preset, counting direction and speed calculation, with cycle time no greater than 1 ms. The 8 mm blind hollow shaft uses a front clamp, while one A-coded M12 male supply connector and two D-coded M12 female Ethernet connectors face axially. The aluminum housing and flange contain a stainless steel shaft. Supply is 10–30 V DC, with consumption no greater than 3 W without load. This is a standard, non-safety product; IP67 housing protection requires fitted mating connectors.

PROFINET absolute encoder with 18-bit × 12-bit multiturn resolution, ≤1 ms cycle time, an 8 mm front-clamped blind hollow shaft and axial M12 connectors.

Key Features

  • 262,144 steps per revolution; 4,096 revolutions; 18 bit × 12 bit
  • PROFINET encoder profile V4.1 class 3
  • 10/100 Mbit/s via CAT-5e cable; cycle time ≤1 ms; initialization 6 s
  • Configurable resolution, preset, direction, speed calculation and round-axis functionality
  • Temperature, speed, voltage and operating/movement counter diagnostics
  • 8 mm blind hollow shaft with front clamp
  • One axial M12 four-pin A-coded male power connector; two axial M12 four-pin D-coded female Ethernet connectors
  • 10–30 V DC; ≤3 W without load; reverse-polarity protection
  • Stainless steel shaft; aluminum flange and housing
  • IP65 shaft side and IP67 housing side, with mating connectors fitted; −40 to +85 °C operation

Read a multi-revolution absolute position over PROFINET and configure position scaling and speed calculation for external machine control.

Technical Specification Matrix

ParameterValue
Product typeMultiturn absolute encoder; standard non-safety product
Steps per revolution262,144, 18 bit
Number of revolutions4,096, 12 bit
Maximum resolution18 bit × 12 bit; 262,144 steps/revolution × 4,096 revolutions
Error limits G0.03°, DIN ISO 1319-1; upper/lower error-limit position depends on installation; specified value assumes symmetric positive and negative deviation
Repeatability standard deviationσr=0.002°, DIN ISO 55350-13; 68.3% of measured values within the stated area
Communication interfacePROFINET
Encoder profileV4.1 class 3
Data transmission rate10 / 100 Mbit/s
Transmission mediumCAT-5e cable
Initialization time6 s
Cycle time≤1 ms
Configurable parametersSteps per revolution; number of revolutions; PRESET; counting direction; speed-calculation sampling rate; speed output unit; round-axis functionality
DiagnosticsMinimum/maximum temperature; maximum speed; power-on counter; operating-hours counters for power-on/motion; direction-change counter; CW/CCW movement counters; maximum supply voltage
Power connectionOne M12 four-pin A-coded male connector, axial
Ethernet connectionsTwo M12 four-pin D-coded female connectors, axial
Power connector pins1 BN=10–30 V DC; 2 WH=not assigned; 3 BU=GND; 4 BK=not assigned
Ethernet connector pinsPorts 1 and 2: 1 yellow=TxD+; 2 white=RxD+; 3 orange=TxD−; 4 blue=RxD−
Local controls and indicationPreset push-button; SF, BF, L/A1 and L/A2 indicators; decimal switches shown out of operation
Power supply10–30 V DC
Power consumption≤3 W without load
Circuit protectionReverse-polarity protection
Shaft configuration8 mm blind hollow shaft; front clamp
Shaft materialStainless steel
Flange and housing materialAluminum
Start-up torque0.8 Ncm at +20 °C
Operating torque0.6 Ncm at +20 °C
Permissible static movement±0.3 mm radial; ±0.5 mm axial
Permissible dynamic movement±0.05 mm radial; ±0.1 mm axial
Operating speed≤6,000 rpm; allow self-heating of 3.3 K per 1,000 rpm when defining the operating temperature range
Rotor moment of inertia40 gcm²
Bearing lifetime3 × 10⁹ revolutions
Angular acceleration≤500,000 rad/s²
Shaft engagement in attachment drawingMinimum 15 mm; maximum 40 mm
IP ratingIP65 shaft side; IP67 housing side, IEC 60529; with mating connectors fitted
Relative humidity90%; condensation not permitted
Operating temperature−40 to +85 °C
Storage temperature−40 to +100 °C without package
Shock resistance100 g, 6 ms, EN 60068-2-27
Vibration resistance30 g, 10–2,000 Hz, EN 60068-2-6
EMCEN 61000-6-2 and EN 61000-6-3
MTTFD80 years, EN ISO 13849-1; nominal component load, average +40 °C and 8,760 h/year; all electronic failures considered hazardous; no safety-component rating
Physical Weight (kg)0.2

Industrial Applications

1. Reading absolute travel on a rotary-driven actuator

An actuator with a suitable rotary transmission can couple its 8 mm shaft to the front-clamped blind hollow encoder. External control reads absolute position over PROFINET and converts revolutions into travel using the actual mechanical ratio. The 4,096-revolution span distinguishes repeated single-turn angles, while configured steps and direction align the reported reference with the machine coordinate convention.

Problem Solved

A multiturn shaft reference lets external actuator control distinguish positions across successive revolutions, helping relate the reported absolute position to mechanical travel within the configured span.

Absolute travel 4,096 revolutions PROFINET

2. Monitoring speed of a driven roller

A driven roller can carry the encoder on an appropriate 8 mm shaft while external process control reads position and configured speed information through PROFINET. The sampling rate for speed calculation and speed output unit are parameterizable. A cycle time no greater than 1 ms supports cyclic communication, with roller geometry and the 6,000 rpm mechanical limit included in application design.

Problem Solved

Configurable speed calculation gives external process control a shaft-motion reference in the required output unit, helping compare driven-roller movement with the intended production rate.

Roller speed Configurable speed unit Cyclic data

3. Recording encoder operating history for maintenance

Machine maintenance software can collect the encoder’s diagnostic counters and extrema alongside the identity of the monitored axis. Available data include power-on and motion operating hours, direction changes, clockwise and counterclockwise movement counts, temperature limits, maximum speed and maximum supply voltage. These observations provide operating context when investigating an axis that behaves differently from its established history.

Problem Solved

Diagnostic counters and recorded extrema give maintenance software usage and environmental context for the axis, helping focus investigations on observed conditions rather than an undifferentiated machine alarm.

Operating history Diagnostic counters Recorded extrema