1. Confirming a part presented to a workstation
A workstation can place the sensor on one side of a presented part and use reflected red light to establish a presence condition for external sequence logic. The sensing-range potentiometer adapts the optical threshold to the installed gap. Setup checks the actual surface against the documented white, gray and black reference-target ranges so the configured condition corresponds to the intended part location.
Problem Solved
A reflected-light presence signal gives external sequencing a part-present reference, helping coordinate the next workstation step when the component reaches the checked position.
Workstation presence
Adjustable range
Single-sided sensing
2. Counting separated components in a feeder
A feeder can move separated components through the illuminated region and send PNP transitions to an external counter. The 1,000 Hz switching rating and response no greater than 500 µs provide timing references for the installed passage rate. Commissioning establishes target coverage, surface remission and spacing so each component produces a distinct event before the next reaches the sensing point.
Problem Solved
Discrete optical transitions give external counting electronics passage events, helping track separated components without placing a receiver or reflector on the opposite side of the feed.
Component count
1,000 Hz
PNP output
3. Timing an occupied downstream receiving point
A transfer station can aim the sensor at a downstream receiving location where a component should remain only briefly. External control measures the detected-state duration and compares it with normal handoff timing. The light/dark selector sets the required PNP logic, and the received-light indicator provides setup feedback while the actual target and background geometry are established.
Problem Solved
A sustained detection state gives external transfer control an occupancy-duration reference, helping coordinate upstream release when a part remains at the downstream receiving point.
Transfer occupancy
External timer