1. Counting opaque packages on a conveyor
A conveyor can place a suitable reflector opposite the sensor and pass separated opaque packages through the returned-light path. The single PNP state supplies passage events to an external counter. Installation uses the range for the actual reflector, including the 0.07–3.5 m P250 sensing range, and checks package coverage and spacing against the response and 1,000 Hz switching specification.
Problem Solved
Returned-light interruptions give external counting electronics package-passage events, helping count separated opaque loads with the optical sender and receiver combined at one mounting location.
Package count
Reflector path
1,000 Hz
2. Monitoring continuity of an opaque web
A web feeder can position the reflector path across a location normally occupied by opaque material. A break or exhausted feed clears the path and changes the PNP state. External monitoring times that condition to distinguish sustained material loss from planned gaps. The documented light/dark selection establishes the controller’s expected signal behavior, while local received-light indication supports setup.
Problem Solved
A sustained optical-state change gives external feeder monitoring a continuity reference, helping identify missing material before a dependent process continues without the intended web.
Web continuity
External timer
PNP state
3. Timing occupancy at a transfer receiving point
A transfer station can place the reflector path across a downstream receiving point so an opaque load interrupts it while the location remains occupied. External control measures the interruption duration against normal handoff time. The installed reflector separation and target coverage are established within the corresponding sensing range, with the local green and yellow indicators assisting alignment and power checks.
Problem Solved
A sustained beam interruption gives external transfer control an occupancy-duration reference, helping coordinate upstream release with clearance of the downstream receiving point.
Transfer occupancy
External timing
Local indication