SICK 1053590 GL6-P7112 PNP Retro-Reflective Sensor

USD 54.08

GL6-P7112 offers 0.07–5 m PL80A sensing, polarized 650 nm PinPoint light, single PNP output, 1,000 Hz switching and a 0.3 m M12 lead.

SKU SICK-1053590 Category
SICK G6

SICK GL6-P7112 PNP Retro-Reflective Sensor

BrandSICK
Model IdentifierGL6-P7112
Official Part Number1053590

Technical Overview

The SICK GL6-P7112 is a polarized dual-lens retro-reflective photoelectric sensor with a minimum reflector separation. Its 650 nm red PinPoint LED provides 0.07–5 m sensing with PL80A, with 0.03–6 m maximum range stated separately. The single PNP output supports light/dark selection, response below 625 µs with resistive load and 1,000 Hz switching at a 1:1 ratio. There is no sensitivity adjustment. The ABS/PC housing has PMMA optics, IP67 protection and a 0.3 m PVC cable with M12 four-pin plug. A BEF-W100-A stainless steel 1.4301/304 bracket and P250 reflector are supplied. Operation uses 10–30 V DC, with maximum output current reduced to 50 mA above 24 V. Green power and yellow received-light indicators assist optical setup.

Polarized red-LED retro-reflective sensor with 0.07–5 m PL80A range, single PNP output, 1,000 Hz switching and 0.3 m PVC cable with M12 four-pin plug.

Key Features

  • Polarized dual-lens retro-reflective sensing; minimum distance to reflector
  • 0.07–5 m sensing; 0.03–6 m maximum with PL80A
  • 650 nm red PinPoint LED; Ø8 mm spot at 350 mm
  • Single PNP output; light/dark selection; no sensitivity adjustment
  • Response <625 µs with resistive load; 1,000 Hz at 1:1 light/dark ratio
  • 10–30 V DC; 30 mA without load; maximum 50 mA output above 24 V
  • 0.3 m PVC cable with M12 four-pin plug; conductor cross-section 0.14 mm²
  • ABS/PC housing; PMMA front screen; IP67
  • BEF-W100-A stainless steel 1.4301/304 bracket and P250 reflector supplied
  • Green supply indicator; yellow received-light indicator; M3 mounting

Monitor interruption of a polarized reflector path and provide a PNP detection state to external machine control in a compact IP67 housing.

Technical Specification Matrix

ParameterValue
Functional principlePolarized dual-lens retro-reflective photoelectric sensing
Sensing range0.07–5 m with PL80A
Maximum sensing range0.03–6 m with PL80A
Other reflector rangesPL40A: 0.07–3.8 m sensing / 0.03–4.3 m maximum; P250: 0.07–3.5 / 0.03–4 m; PL20A: 0.07–2.2 / 0.03–2.5 m; REF-IRF-56 tape: 0.25–1.6 / 0.2–1.8 m
Polarization filterProvided
Light sourceVisible red PinPoint LED; 650 nm
Average LED service life100,000 h at +25 °C
Light spot sizeØ8 mm at 350 mm
Additional spot sizesØ25 mm at 1 m; Ø80 mm at 3 m; Ø130 mm at 5 m
Sensitivity adjustmentNone
Switching outputSingle PNP
Switching modeLight/dark switching; selectable via light/dark selector
PNP signal HIGH/LOWSupply voltage −(≤3 V) / approximately 0 V
Output current≤100 mA; maximum 50 mA when supply >24 V
Response time<625 µs signal transit time with resistive load
Switching frequency1,000 Hz at 1:1 light/dark ratio
Power supply10–30 V DC; short-circuit-protected network, maximum 8 A
Ripple±10%; remain within supply tolerances
Current consumption30 mA without load
Circuit protectionSupply and input/output reverse-polarity protection; output overcurrent and short-circuit protection
Protection classIII
Connection0.3 m PVC cable with M12 four-pin plug; do not bend below 0 °C
Conductor cross-section0.14 mm²
Conductor functionsCD-066: 1 BN=L+; 2 WH=not connected; 3 BU=M; 4 BK=Q
Housing designRectangular
Housing materialABS/PC plastic
Front screenPMMA plastic
Items suppliedBEF-W100-A stainless steel 1.4301/304 bracket and P250 reflector
MountingM3 holes; 25.4 mm spacing
IndicationGreen: supply voltage active; yellow: received-light-beam state
IP ratingIP67
Operating temperature−25 to +55 °C; manufacturer specifies temperature stability following adjustment ±10 °C
Storage temperature−40 to +70 °C
UL fileNRKH.E348498 and NRKH7.E348498
MTTFD2,141 years
DCavg0%
Mission time20 years
Physical Weight (kg)0.06

Industrial Applications

1. Counting opaque packages on a conveyor

A conveyor can place a suitable reflector opposite the sensor and pass separated opaque packages through the returned-light path. The single PNP state supplies passage events to an external counter. Installation uses the range for the actual reflector, including the 0.07–3.5 m P250 sensing range, and checks package coverage and spacing against the response and 1,000 Hz switching specification.

Problem Solved

Returned-light interruptions give external counting electronics package-passage events, helping count separated opaque loads with the optical sender and receiver combined at one mounting location.

Package count Reflector path 1,000 Hz

2. Monitoring continuity of an opaque web

A web feeder can position the reflector path across a location normally occupied by opaque material. A break or exhausted feed clears the path and changes the PNP state. External monitoring times that condition to distinguish sustained material loss from planned gaps. The documented light/dark selection establishes the controller’s expected signal behavior, while local received-light indication supports setup.

Problem Solved

A sustained optical-state change gives external feeder monitoring a continuity reference, helping identify missing material before a dependent process continues without the intended web.

Web continuity External timer PNP state

3. Timing occupancy at a transfer receiving point

A transfer station can place the reflector path across a downstream receiving point so an opaque load interrupts it while the location remains occupied. External control measures the interruption duration against normal handoff time. The installed reflector separation and target coverage are established within the corresponding sensing range, with the local green and yellow indicators assisting alignment and power checks.

Problem Solved

A sustained beam interruption gives external transfer control an occupancy-duration reference, helping coordinate upstream release with clearance of the downstream receiving point.

Transfer occupancy External timing Local indication