| Functional principle | Incremental rotary encoder |
| Pulses per revolution | 5,000 |
| Measuring step | 90 electrical degrees / pulses per revolution |
| Output interface | TTL / RS-422; fixed electrical interface |
| Signal channels | Six: A, A complement, B, B complement, Z, Z complement |
| Reference signal | One reference signal per revolution |
| Reference signal position | 90 electrical degrees; logically gated with A and B |
| Load current | ≤30 mA |
| Power supply | 4.5–5.5 V |
| Output frequency | ≤600 kHz |
| Operating speed | ≤9,000 rpm |
| Speed-related self-heating | Allow 3.3 K per 1,000 rpm when designing the operating temperature range |
| Shaft material | Stainless steel |
| Flange material | Aluminum |
| Angular acceleration | ≤500,000 rad/s² |
| Permissible relative humidity | 90%; condensation not permitted |
| Storage temperature | −40 to +100 °C, without package |
| Measuring step deviation | ±0.01° at non-binary number of lines |
| Error limits | ±0.05° |
| Initialization time | 40 ms |
| Operating current | 40 mA without load |
| Connection | Radial M12 eight-pin male connector |
| M12 pin assignment | 1=A complement; 2=A; 3=B complement; 4=B; 5=Z complement; 6=Z; 7=GND; 8=+Us |
| Screen connection | Screen connected to housing on encoder side; connected to ground on control side |
| Output short-circuit protection | Against another channel, Us or GND, maximum 30 s |
| Mechanical design | Solid shaft with flat; face-mount flange |
| Shaft diameter | 10 mm |
| Shaft length | 19 mm nominal; drawing tolerance ±0.3 mm |
| Housing material | Aluminum die cast |
| Startup torque | 0.5 Ncm at +20 °C |
| Operating torque | 0.3 Ncm at +20 °C |
| Permissible shaft loading | 80 N radial; 40 N axial |
| Rotor moment of inertia | 6.2 gcm² |
| Bearing lifetime | 3.6 × 10^10 revolutions |
| Mounting holes | Three M4, 6 mm deep, at 120° on Ø48 ±0.05 mm pitch circle |
| IP rating | IP67 housing side and male connector with mating connector fitted; IP65 shaft side; IEC 60529 |
| Operating temperature | −40 to +100 °C with stationary cable; −30 to +100 °C with flexible cable |
| Shock resistance | 70 g, 6 ms; EN 60068-2-27 |
| Vibration resistance | 30 g, 10–2,000 Hz; EN 60068-2-6 |
| EMC | EN 61000-6-2 and EN 61000-6-3 |
| MTTFD | 300 years, EN ISO 13849-1; standard product, not a safety component; nominal component load, average ambient 40 °C, 8,760 h/year |
| Physical Weight (kg) | 0.3 |