SICK 6013620 VL18-3F3740 PNP Polarized Retro-Reflective Sensor

USD 91.26

VL18-3F3740 offers 0.05–3 m sensing with C110A reflector, polarized red LED light, PNP light switching, 270° sensitivity adjustment and M12 connection.

SKU SICK-6013620 Category
SICK V18

SICK VL18-3F3740 PNP Polarized Retro-Reflective Sensor

BrandSICK
Model IdentifierVL18-3F3740
Official Part Number6013620

Technical Overview

The SICK VL18-3F3740 is an axial M18 × 1 photoelectric retro-reflective sensor with a polarizing filter and visible red LED light. With a C110A reflector, sensing range is 0.05–3 m and maximum range is 0.05–3.7 m. The beam has an approximately 2.8° dispersion angle and a Ø150 mm spot at 3 m. A 270° potentiometer adjusts sensitivity, while the PNP output operates in light-switching mode. Response is ≤2 ms with resistive load and switching frequency is 250 Hz at a 1:1 light/dark ratio. The 10–30 V DC device uses an M12 four-pin male connector, IP67 PBT/PC housing and PMMA optics, with operation from −25 to +70 °C.

Polarized M18 retro-reflective sensor with 0.05–3 m C110A range, visible red LED, PNP light switching and M12 four-pin connection.

Key Features

  • Photoelectric retro-reflective sensing with polarizing filter
  • 0.05–3 m sensing and 0.05–3.7 m maximum range with C110A reflector
  • Visible red LED; Ø150 mm spot at 3 m
  • Approximately 2.8° focus/dispersion; axial M18 × 1 cylindrical design
  • 270° sensitivity potentiometer and yellow signal-strength indicator
  • PNP light-switching output; output current ≤100 mA
  • Response ≤2 ms with resistive load; 250 Hz at 1:1 light/dark ratio
  • 10–30 V DC; 30 mA no-load current; M12 four-pin male connector
  • Supply/input/output reverse-polarity protection, interference suppression and output overcurrent/short-circuit protection
  • PBT/PC housing, PMMA optics and IP67; operation −25 to +70 °C

Detect interruptions of the reflector return path with polarized red light and a light-switching PNP output, keeping powered wiring at the sensor side.

Technical Specification Matrix

ParameterValue
Functional principlePolarized photoelectric retro-reflective sensor
Housing designCylindrical; M18 × 1; axial optical axis
Housing length78 mm, connector version
Sensing range0.05–3 m with C110A reflector
Maximum sensing range0.05–3.7 m with C110A reflector
Light sourceVisible red LED
Average LED service life100,000 h at +25 °C
Light spot sizeØ150 mm at 3 m
Focus and dispersion angleApproximately 2.8°
Adjustment270° sensitivity potentiometer
Polarizing filterYes
Signal indicatorYellow signal-strength LED
Power supply10–30 V DC
Ripple±10%; remain within supply tolerances
Current consumption30 mA without load
Switching outputPNP; maximum output current ≤100 mA
Switching modeLight switching
Response time≤2 ms; signal transit time with resistive load
Switching frequency250 Hz at 1:1 light/dark ratio
ConnectionM12 four-pin male connector
Circuit protectionSupply connections reverse-polarity protected; inputs/output reverse-polarity protected; interference suppression; outputs overcurrent and short-circuit protected
Protection classIII
Housing materialPBT/PC
Optics materialPMMA
IP ratingIP67
Operating temperature−25 to +70 °C
UL fileNMFT2.E175606
MTTFD68 years
DCavg0%
Physical Weight (kg)0.1

Industrial Applications

1. Counting opaque cartons against a fixed reflector

A conveyor can mount the sensor on one side and a C110A reflector opposite it, with separated opaque cartons crossing the return-light path. Each interruption changes the light-switching PNP output for an external counter. The 0.05–3 m sensing range and 250 Hz rating establish the optical and timing context, with carton spacing and input sampling set for distinct events.

Problem Solved

A reflected-beam interruption gives external counting logic a carton-passage event while keeping powered wiring on one side of the conveyor and a passive reflector opposite.

Carton counting C110A reflector PNP light switching

2. Monitoring opaque web continuity at a feed station

An opaque web feeder can position the sensor and reflector across the expected material path so intact material blocks the returned light. A break or exhausted web opens the path and changes the PNP signal. The 270° sensitivity potentiometer adjusts the optical setting for the installed reflector distance, while external monitoring applies the expected light-switching polarity to the material state.

Problem Solved

A sustained optical-path opening provides external feed monitoring with a material-continuity event, helping identify a break or exhausted opaque web before the next process step.

Opaque web Sensitivity adjustment Continuity monitoring

3. Detecting a blocked conveyor discharge position

A discharge station can place the beam across the receiving position with a passive reflector opposite the sensor. An opaque load remaining there holds the light-switching output in its interrupted state. External sequencing measures that duration and delays upstream release while the position remains occupied, accounting for the sensor response time and the installed optical path.

Problem Solved

Signal duration lets external sequencing distinguish a passing load from sustained discharge blockage, helping coordinate upstream release with the availability of the receiving position.

Discharge blockage Signal duration Passive reflector
Select your currency