| Functional principle | Photoelectric proximity sensor with background suppression |
| Sensing range | 10–70 mm on 90% remission reference white, DIN 5033 |
| Maximum sensing range | 4–90 mm on 90% remission reference white, DIN 5033 |
| Preset sensing distance | 45 mm |
| Target-dependent ranges | 18% gray: sensing 10–70 mm, maximum 5–80 mm; 6% black: sensing 10–70 mm, maximum 6–70 mm; 1% ultra-black: sensing 15–40 mm, maximum 8–40 mm, manufacturer range diagram |
| Light source | 640 nm visible red PinPoint LED |
| Average LED service life | 100,000 h at +25 °C |
| Light spot size | Line-shaped, 2.2 × 9 mm at 45 mm |
| Spot size by distance | Vertical × horizontal: at 0 mm 3.5 × 3.8 mm; 10 mm 3.0 × 5.2; 20 mm 3.3 × 6.4; 30 mm 1.8 × 7.4; 40 mm 2.0 × 8.6; 60 mm 4.4 × 10.5; 80 mm 6.5 × 12.8; 100 mm 9.0 × 14.5, all spot values in mm |
| Documented target roles | Small, perforated, uneven or shiny objects; film-wrapped objects; objects with position tolerances |
| Adjustment | IO-Link |
| Switching output | PNP, parameterizable via IO-Link; pin 4 must not be connected to another output |
| Switching mode | Programmable light/dark switching through IO-Link |
| Pin 2 functions | External input; teach-in input; sender-off input; detection output; logic output |
| Output current | ≤50 mA |
| General response time | <0.5 ms with resistive load, manufacturer mechanics table |
| Configured pin 2 timing | Q̅ on pin 2, if configured in software: 300–450 µs response with resistive load; 150 µs repeatability; 1,000 Hz at 1:1 light/dark ratio |
| General switching frequency | 1,000 Hz, manufacturer mechanics table |
| IO-Link | V1.1; COM2, 38.4 kBaud; cycle time 2.3 ms |
| Process data | 16 bit: bit 0=QL1; bit 1=QL2; bits 2–15 empty |
| IO-Link identifiers | VendorID 26; DeviceID 0x800121 (8388897) |
| Master compatibility | Port type A; SIO mode supported |
| Smart Task | Base logics |
| Logic functions | Direct; AND; OR; WINDOW; hysteresis |
| Timer functions | Deactivated; switch-on delay; off delay; ON and OFF delay; impulse (one shot) |
| Inverter | Supported |
| Mode-specific switching frequency | SIO Direct 1,000 Hz; SIO Logic 1,000 Hz; full IOL 900 Hz |
| Mode-specific response time | SIO Direct 300–450 µs; SIO Logic 500–600 µs; full IOL 500–900 µs |
| Mode-specific repeatability | SIO Direct 150 µs; SIO Logic 150 µs; full IOL 400 µs |
| Operating-mode definitions | SIO Direct: no IO-Link communication and internal logic/timers set to direct/deactivated; SIO Logic: no IO-Link communication, internal logic/timing and Automation Functions used; IOL: full IO-Link communication with logic/timing and Automation Functions |
| Logic switching signals | QL1 and QL2 switching outputs |
| Diagnosis | Device status |
| Power supply | 10–30 V DC, limit values |
| Ripple | <5 Vpp; remain within supply-voltage tolerances |
| Current consumption | 20 mA without load |
| Connection | 200 mm PVC cable with M8 four-pin male connector; do not bend below 0 °C |
| Conductor cross-section | 0.09 mm² |
| Cable diameter | Ø3 mm |
| Pin assignment | CD-367: 1 BN=L+; 4 BK=QL1/C; 2 WH=MF; 3 BU=M |
| Circuit protection | Supply and output reverse-polarity protection; output overcurrent and short-circuit protection |
| Protection class | III |
| Housing design | Rectangular |
| Housing material | ABS/PC |
| Optics material | PMMA |
| IP rating | IP67 |
| Operating temperature | −25 to +50 °C |
| Storage temperature | −40 to +75 °C |
| Mounting | Ø3.2 mm holes; 15 mm center spacing |
| Indicators | Green: supply voltage; yellow: received-light-beam status |
| UL file | NRKH.E181493 |
| MTTFD | 1,547 years |
| DCavg | 0% |