SICK 1040998 IME30-10BPSZC0S PNP NO Inductive Sensor

USD 38.74

IME30-10BPSZC0S offers 10 mm nominal inductive range, 8.1 mm assured range, flush M30 mounting, PNP normally-open output, 500 Hz and M12 connection.

SKU SICK-1040998 Category
SICK IME

SICK IME30-10BPSZC0S PNP NO Inductive Sensor

BrandSICK
Model IdentifierIME30-10BPSZC0S
Official Part Number1040998

Technical Overview

The SICK IME30-10BPSZC0S is a standard-design M30 × 1.5 inductive proximity sensor for flush installation. Nominal sensing range is 10 mm and assured sensing range is 8.1 mm, with target-material reduction factors for non-reference metals. Its PNP normally-open output uses DC three-wire signaling and switches at 500 Hz. The nickel-plated brass housing has a PA 66 sensing face, IP67 protection and an M12 four-pin male connector. Supply is 10–30 V DC, continuous output current is no more than 200 mA and no-load consumption is no more than 10 mA. Two nickel-plated brass mounting nuts are supplied, and operation spans −25 to +75 °C.

Flush M30 inductive sensor with 10 mm nominal range, 8.1 mm assured range, PNP normally-open output, 500 Hz switching and M12 four-pin connection.

Key Features

  • Standard-design M30 × 1.5 housing for flush installation
  • 10 mm nominal sensing range; 8.1 mm assured sensing range
  • PNP normally-open output; DC three-wire signaling
  • 500 Hz switching frequency
  • 10–30 V DC; ≤10 mA no-load current; ≤200 mA continuous output
  • M12 four-pin male connector; pin 4=NO, pin 2 unused
  • Nickel-plated brass housing; PA 66 sensing face; IP67
  • Two nickel-plated brass mounting nuts supplied; 36 mm across flats
  • Short-circuit and power-up pulse protection
  • −25 to +75 °C operating temperature; maximum tightening torque 100 Nm

Mount the M30 sensing face flush with its support and provide a normally-open inductive position event to external machine sequencing.

Technical Specification Matrix

ParameterValue
Functional principleInductive proximity sensing
Housing designMetric, standard design
Mounting threadM30 × 1.5
Body diameterØ30 mm
InstallationFlush
Nominal sensing range Sn10 mm
Assured sensing range Sa8.1 mm
Material reduction factorsReference values, may vary: St37 steel 1; stainless steel V2A/304 approximately 0.8; aluminum approximately 0.45; copper approximately 0.4; brass approximately 0.4
Switching outputPNP, normally open (NO)
Electrical wiringDC three-wire
Switching frequency500 Hz
ConnectionM12 four-pin male connector
Pin assignmentCD-007: 1 BN=L+; 4 BK=NO; 3 BU=M; pin 2 not connected
Power supply10–30 V DC
Ripple≤10%
Voltage drop≤2 V at maximum continuous current
Availability delay≤125 ms
Continuous output current≤200 mA
No-load current≤10 mA
Hysteresis5–15%
Reproducibility≤2% of Sr at constant supply voltage and ambient temperature
Temperature drift±10% of Sr
Short-circuit protectionYes
Power-up pulse protectionYes
Shock resistance30 g, 11 ms
Vibration resistance10–55 Hz, 1 mm
EMCEN 60947-5-2
Operating temperature−25 to +75 °C
Housing materialNickel-plated brass
Sensing face materialPA 66 plastic
Housing length71 mm, including connector as shown
Thread length54 mm
Maximum tightening torque≤100 Nm
Items suppliedTwo nickel-plated brass mounting nuts; 36 mm across flats
Installation clearancesManufacturer flush-installation diagram: B=30 mm, C=30 mm, D=30 mm, F=80 mm
IndicatorDisplay LED
IP ratingIP67 according to EN 60529
UL fileNRKH.E181493
MTTFD1,735 years
DCavg0%

Industrial Applications

1. Confirming that a metal clamp reaches its seated position

A fixture can present a metal clamp target to the flush sensing face when the clamp reaches its seated position. External sequencing reads the normally-open PNP state before permitting the next operation. Mechanical setup establishes a suitable gap using the 10 mm nominal and 8.1 mm assured ranges, while accounting for the actual metal’s reduction factor and the specified flush-installation clearances.

Problem Solved

An inductive seated-position event gives external sequencing evidence that the metal target has reached the observation point, helping coordinate the next fixture operation without a contact switch.

Clamp position Flush M30 PNP NO

2. Counting separated metal features on a moving mechanism

A moving mechanism can pass separated metal flags or features across the sensing face and send PNP transitions to an external counter. The 500 Hz rating provides the sensor timing basis for the selected feature spacing and movement speed. Setup verifies the actual metal, sensing gap and controller input response so successive features produce separate normally-open switching events.

Problem Solved

Repeated inductive transitions give an external counter feature-passage events, helping track movement cycles or separated metal items without mechanically contacting the moving target.

Metal-feature count 500 Hz Noncontact events

3. Checking that a metal carrier leaves a transfer point

A transfer point can place the sensor beside a metal carrier target at its stopped position. External sequencing checks the normally-open output before release and again after the movement command. A target that remains within the inductive observation gap retains the detected condition, allowing external timing logic to flag a carrier that has not cleared the station.

Problem Solved

A before-and-after metal-presence condition gives external transfer logic evidence of carrier departure, helping identify a retained load before another carrier enters the same position.

Carrier departure Metal presence Transfer sequence