SICK 1071286 IME30-20BPOZC0K PNP NC Inductive Sensor

USD 110.50

IME30-20BPOZC0K offers 20 mm nominal inductive range, 16.2 mm assured range, quasi-flush M30 mounting, PNP normally-closed output and M12 connection.

SKU SICK-1071286 Category
SICK IME

SICK IME30-20BPOZC0K PNP NC Inductive Sensor

BrandSICK
Model IdentifierIME30-20BPOZC0K
Official Part Number1071286

Technical Overview

The SICK IME30-20BPOZC0K is a short-body M30 × 1.5 inductive proximity sensor for quasi-flush installation with 6 mm protrusion in the manufacturer’s mounting diagram. Its triple-range design specifies 20 mm nominal and 16.2 mm assured sensing, with target-material reduction factors. The PNP normally-closed output uses DC three-wire signaling and switches at 200 Hz. A four-pin M12 connector assigns the NC output to pin 2 and leaves pin 4 unconnected. The nickel-plated brass housing and PA 66 sensing face provide IP67 protection. Supply is 10–30 V DC, warm-up time is 60 s and operation spans −25 to +75 °C. Two nickel-plated brass mounting nuts are supplied.

Quasi-flush M30 inductive sensor with 20 mm nominal range, 16.2 mm assured range, PNP normally-closed output on pin 2 and M12 four-pin connection.

Key Features

  • Short-body M30 × 1.5 for quasi-flush installation; 6 mm protrusion
  • Triple sensing range: 20 mm nominal and 16.2 mm assured
  • PNP normally-closed output; DC three-wire signaling
  • 200 Hz switching frequency
  • M12 four-pin male connector; pin 2=NC, pin 4 unused
  • 10–30 V DC; ≤200 mA continuous output; ≤10 mA no-load current
  • 60 s warm-up time; availability delay ≤200 ms
  • Nickel-plated brass housing, PA 66 sensing face and IP67
  • Two nickel-plated brass mounting nuts supplied; 36 mm across flats
  • −25 to +75 °C operating and storage temperature

Use extended-range inductive sensing at a quasi-flush M30 mounting point and deliver a normally-closed metal-position signal through M12 pin 2.

Technical Specification Matrix

ParameterValue
Functional principleInductive proximity sensing
Housing designMetric, short-body
Mounting threadM30 × 1.5
Body diameterØ30 mm
InstallationQuasi-flush; 6 mm protrusion E in manufacturer installation diagram
Nominal sensing range Sn20 mm
Assured sensing range Sa16.2 mm
Special featureTriple sensing range
Material reduction factorsReference values, may vary: St37 steel 1; stainless steel V2A/304 approximately 0.78; aluminum approximately 0.35; copper approximately 0.27; brass approximately 0.38
Switching outputPNP, normally closed (NC)
Electrical wiringDC three-wire
Switching frequency200 Hz
ConnectionM12 four-pin male connector
Pin assignmentCD-008: 1 BN=L+; 2 WH=NC; 3 BU=M; 4 BK=not connected
Power supply10–30 V DC
Ripple≤10%
Voltage drop≤2 V at maximum continuous current
Availability delay≤200 ms
Warm-up time60 s
Hysteresis1–15%
Reproducibility≤5% of Sr at constant supply voltage and ambient temperature
Temperature drift±10% of Sr
Continuous output current≤200 mA
No-load current≤10 mA
Short-circuit protectionYes
Power-up pulse protectionYes
Shock resistance30 g, 11 ms
Vibration resistance10–55 Hz, 1 mm
EMCEN 60947-5-2
Operating temperature−25 to +75 °C
Storage temperature−25 to +75 °C
Housing materialNickel-plated brass
Sensing face materialPA 66 plastic
Housing length52 mm including connector as shown
Thread length35 mm
Maximum tightening torque≤70 Nm
Items suppliedTwo nickel-plated brass mounting nuts; 36 mm across flats
Installation clearancesManufacturer quasi-flush diagram: A=33 mm; B=80 mm; C=30 mm; D=60 mm; E=6 mm; F=200 mm
IndicatorDisplay LED
IP ratingIP67 according to EN 60529
UL fileNRKH.E181493
MTTFD1,735 years
DCavg0%

Industrial Applications

1. Confirming a metal clamp at its seated position

A fixture can present a metal clamp target to the sensor when the clamp reaches its seated position. External sequencing interprets the normally-closed PNP state as the target enters the observation zone. Mechanical setup uses the 20 mm nominal and 16.2 mm assured ranges with the actual metal reduction factor, and retains the documented quasi-flush protrusion and surrounding clearances.

Problem Solved

An inductive seated-position condition gives external sequencing evidence that the metal target has reached the intended fixture location, helping coordinate the next assembly operation.

Clamp position 20 mm nominal Quasi-flush

2. Counting separated metal flags on a moving mechanism

A moving mechanism can pass separated metal flags across the sensing face and send normally-closed PNP transitions to an external counter. The 200 Hz rating supplies the switching-frequency basis for choosing flag spacing and movement speed. Setup verifies the actual flag material, sensing gap and controller input behavior, then enables counting after the specified warm-up period.

Problem Solved

Repeated inductive transitions give external counting logic metal-feature passage events, helping track mechanism cycles or feed movement without mechanically contacting the moving flags.

Metal-feature count 200 Hz PNP NC

3. Checking that a metal carrier clears a transfer stop

A transfer stop can bring a defined metal carrier feature into the inductive observation zone. External sequencing checks the NC output before release and after the movement command, interpreting the change as target departure. A carrier that remains at the stop holds the detected target condition, allowing external timing logic to identify an uncleared transfer position.

Problem Solved

A before-and-after metal-presence check gives external transfer logic evidence of departure, helping identify a retained carrier before another carrier reaches the same stop.

Carrier departure Metal presence NC state
Select your currency