SICK 1059631 GL6-N4211 NPN Polarized Retro-Reflective Sensor

USD 61.88

Polarized red PinPoint retro sensing with 0.07–5 m PL80A range, NPN light/dark output, 1,000 Hz switching, 270° adjustment and M8 four-pin connector.

SKU SICK-1059631 Category
SICK G6

SICK GL6-N4211 NPN Polarized Retro-Reflective Sensor

BrandSICK
Model IdentifierGL6-N4211
Official Part Number1059631

Technical Overview

The SICK GL6-N4211 is a polarized retro-reflective photoelectric sensor using dual-lens optics with a minimum reflector distance. With PL80A, its sensing range is 0.07–5 m and its maximum range is 0.03–6 m. A 650 nm red PinPoint LED produces an 8 mm spot at 350 mm, while a 270° potentiometer adjusts sensitivity. One NPN output provides selectable light or dark switching, with response below 625 µs and 1,000 Hz switching under the stated test conditions. The 10–30 V DC sensor has an M8 four-pin connector, M3 mounting holes, ABS/PC housing and PMMA front screen, with IP67 protection and supply-dependent output-current derating.

Polarized dual-lens retro sensor with 0.07–5 m PL80A range, NPN light/dark output, red PinPoint LED, 270° adjustment and M8 four-pin connector.

Key Features

  • Polarized retro-reflective sensing with dual-lens optics
  • PL80A sensing range 0.07–5 m; maximum range 0.03–6 m
  • 650 nm red PinPoint LED; Ø8 mm spot at 350 mm
  • 270° sensitivity potentiometer
  • One NPN output with local light/dark selector
  • Response <625 µs with resistive load; 1,000 Hz at 1:1 light/dark ratio
  • Output current ≤100 mA; maximum 50 mA above 24 V supply
  • 10–30 V DC; 30 mA consumption without load
  • M8 four-pin male connector; M3 mounting holes
  • ABS/PC housing, PMMA front screen and IP67

Align a visible polarized reflector beam and select the NPN switching state locally to provide external control with a beam-interruption signal.

Technical Specification Matrix

ParameterValue
Functional principlePolarized photoelectric retro-reflective sensing
Optical arrangementDual-lens system with minimum distance to reflector
Reference reflectorPL80A
Sensing range0.07–5 m with PL80A
Maximum sensing range0.03–6 m with PL80A
Polarization filterProvided
Light source650 nm visible red PinPoint LED
Average LED service life100,000 h at +25 °C
Light spot sizeØ8 mm at 0.35 m; Ø25 mm at 1 m; Ø80 mm at 3 m; Ø130 mm at 5 m
AdjustmentSensitivity potentiometer, 270°
OutputOne NPN switching output
Switching modeLight/dark, selectable by rotary selector: L=light; D=dark
NPN voltage HIGH/LOWApproximately supply voltage / ≤3 V
Output current≤100 mA; maximum 50 mA at supply >24 V
Response time<625 µs, signal transit with resistive load
Switching frequency1,000 Hz at 1:1 light/dark ratio
Power supply10–30 V DC; short-circuit-protected network, maximum 8 A
Ripple±10%; remain within supply-voltage tolerances
Current consumption30 mA without load
Circuit protectionSupply reverse polarity; input/output reverse polarity; output overcurrent and short circuit
Protection classIII
ConnectionM8 four-pin male connector
Pin assignmentCD-066: 1 BN=L+; 2 WH=not connected; 3 BU=M; 4 BK=Q
MountingM3 mounting holes
IndicatorsGreen: supply voltage; yellow: received-light status
Housing materialABS/PC plastic
Front screenPMMA plastic
IP ratingIP67
Operating temperature−25 to +55 °C; temperature stability following adjustment ±10 °C
Storage temperature−40 to +70 °C
UL filesNRKH.E348498 and NRKH7.E348498
MTTFD1,609 years
Other reflector sensing rangesPL40A: 0.07–3.8 m; P250: 0.07–3.5 m; PL20A: 0.07–2.2 m; REF-IRF-56 tape: 0.25–1.6 m
Other reflector maximum rangesPL40A: 0.03–4.3 m; P250: 0.03–4 m; PL20A: 0.03–2.5 m; REF-IRF-56 tape: 0.2–1.8 m
Physical Weight (kg)0.02

Industrial Applications

1. Counting separated loads on a narrow conveyor

A narrow conveyor can mount the sensor opposite a suitable reflector and send beam-interruption transitions to an external counter. The polarized dual-lens arrangement provides the optical path, and the NPN output connects to a compatible counting input. Load coverage and spacing determine distinct events within the documented 1,000 Hz and resistive-load response conditions, using the range of the selected reflector.

Problem Solved

Beam interruptions give an external counter discrete load-passage events, helping track separated packages without relying on reflected light from each package surface.

Load counting NPN output Polarized retro

2. Confirming clearance before a transfer begins

A transfer station can place the reflector beam across the handover path and use the selected light/dark output state as an external clearance condition. Local sensitivity adjustment establishes received-light margin for the installed reflector. External sequencing reads the configured NPN condition before releasing the next load, accounting for the minimum reflector distance and actual target coverage of the beam.

Problem Solved

The reflector-beam condition gives external sequencing a path-clearance reference, helping coordinate load release with the observed occupancy of the transfer opening.

Transfer clearance Light/dark selector External sequence

3. Monitoring the continuity of a fed opaque strip

A feed machine can route an opaque strip across the beam between the sensor and reflector and use a restored beam as a strip-discontinuity event. External control interprets that event in the feed sequence. The arrangement holds the strip across the optical path and uses the documented reflector range and selected output mode to distinguish material coverage from an opening.

Problem Solved

A change in beam coverage gives external feed control a strip-continuity reference, helping identify an exhausted or broken material presentation before further processing.

Strip continuity Reflector path NPN switching