| Product type | 2D LiDAR field-evaluation sensor |
| Application | Indoor |
| Measurement principle | HDDM+ |
| Light source | 850 nm infrared laser |
| Laser class | 1; IEC 60825-1:2014 and EN 60825-1:2014+A11:2021 |
| Horizontal aperture angle | 270° |
| Scanning frequency | 15 Hz |
| Horizontal angular resolution | 1° |
| Working range | 0.05–4 m |
| Range at 10% remission | 2 m |
| Response time | One scan: typical 67 ms; two scans: ≤134 ms at +45° to +225°; maximum 150 ms at −45° to +45° |
| Detectable object shape | Almost any |
| Systematic error | ±40 mm, typical at 90% remission up to maximum scanning range; actual value depends on ambient conditions |
| Statistical error | <30 mm, typical at 90% remission up to maximum scanning range; actual value depends on ambient conditions |
| Integrated application | Field evaluation |
| Field sets | Sixteen field triples, 48 fields; one triple of three flexible fields configurable directly at scanner |
| Simultaneous evaluation | One evaluation case, three fields |
| Digital inputs | Four, binary selection of one of sixteen field sets |
| Digital outputs | Three NPN field outputs plus one Device Ready output; ≤100 mA output current |
| Delay time | 67–30,000 ms, configurable |
| Dwell time | 67–600,052 ms, configurable |
| Service interface | Micro-USB for service and parameterization |
| Optical indicators | Two LEDs for ON and switching status |
| Local control | Teach-in function button |
| Power supply | 9–28 V DC |
| Power consumption | Typical 4 W; 16 W with four maximally loaded digital outputs |
| Connection | 2 m open-wire cable; some units delivered with a removable-by-cutting 15-pin D-Sub HD male connector, as described in manufacturer instructions |
| Cable construction | Fifteen conductors with shield, for TiM3xx-01xxxxx configuration |
| Supply and unused conductors | Red=Vs; black=GND; violet, yellow, light blue and dark blue=not connected |
| Field-input conductors | IN1=turquoise or light gray; IN2=green; IN3=gray; IN4=pink; white/black=NPN input common reference Vs |
| Output conductors | OUT1=brown; OUT2=orange; OUT3=white; OUT4=red/black index/error output; metal screen=shield |
| Housing color | Light blue, RAL 5012 |
| IP rating | IP65; IEC 60529:1989+AMD1:1999+AMD2:2013 |
| Protection class | III; IEC 61140:2016-1 |
| MTBF | >100 years |
| MTTFD | 100 years |
| Remission range | 4–1,000%, including reflectors |
| Ambient-light immunity | 80,000 lx |
| EMC emissions | Residential-area standard EN 61000-6-3:2007+AMD:A1:2011 |
| EMC immunity | Industrial-environment standard EN 61000-6-2:2005 |
| Vibration resistance | IEC 60068-2-6:2007: sine resonance scan 10–1,000 Hz; sine test 10–500 Hz, 5 g, ten frequency cycles; IEC 60068-2-64:2008: noise 10–250 Hz, 4.24 g RMS, 5 h |
| Shock resistance | IEC 60068-2-27:2008: 50 g/11 ms, ±3 single shocks per axis; 25 g/6 ms, ±1,000 continuous shocks per axis; 50 g/3 ms, ±5,000 continuous shocks per axis |
| Operating temperature | −10 to +50 °C, IEC 60068-2-14:2009 |
| Switch-on temperature | −10 to +50 °C |
| Storage temperature | −30 to +70 °C, IEC 60068-2-14:2009 |
| Temperature-change test | −10 to +50 °C, ten cycles, EN 60068-2-14:2009 |
| Damp-heat test | +25 to +55 °C, 95% RH, six cycles, EN 60068-2-30:2005 |
| Operating humidity | <80% RH, non-condensing, EN 60068-2-30:2005 |
| Storage humidity | ≤90% RH, non-condensing, EN 60068-2-30:2005 |
| Items supplied in drawing | Two straight mounting plates with M3 ×4 mm screws |
| Mounting interface | M3 blind threaded holes, 2.8 mm deep; maximum tightening torque 0.8 Nm |
| Intended control role | Process field sensing; manufacturer identifies this sensor as not a machine-safety component |