1. Checking an insert in an assembly nest
An assembly nest can present an insert at a repeatable distance facing the axial sensing surface. The potentiometer establishes a reflected-light sensitivity condition, and external inspection logic samples the complementary PNP outputs after the assembly settles. Commissioning evaluates actual insert remission and the surrounding fixture because energetic detection depends on returned light, with shorter documented ranges for darker targets.
Problem Solved
An insert-present condition helps external inspection logic identify an empty assembly location before the next operation, using reflected light from a repeatably presented target surface.
Insert presence
Sensitivity adjustment
PNP outputs
2. Counting separated packages along a compact feed lane
A compact feed lane can pass separated packages through the axial red sensing spot and send PNP switching transitions to an external counter. The 500 Hz rating and response below 1,000 µs with resistive load inform timing assessment alongside package size, spacing and controller response. Setup establishes sensitivity with representative package surfaces and respects supply- and temperature-dependent output-current limits.
Problem Solved
Package-passage transitions provide discrete events for external counting logic, helping track separated material movement through one compact sensing point without an opposed optical receiver.
Package counting
500 Hz
Axial red LED
3. Reporting a stack reaching a selected replenishment level
A replenishment station can mount the threaded sensor beside a stack of consistent opaque components at the selected level. Reflected light from the approaching stack surface changes the complementary PNP condition for external replenishment logic. The potentiometer establishes sensitivity using representative material, while commissioning evaluates target color, mounting gap and background reflections within the appropriate target-dependent sensing range.
Problem Solved
A stack-at-level condition gives external replenishment logic a discrete material reference, helping coordinate replenishment from the installed sensing height using light returned from the components.
Stack level
M18 mounting
Complementary outputs