1. Identifying a carrier before a routing decision
A transfer station can present one compatible HF transponder on a stopped carrier to the integrated antenna and read its UID. External routing software associates that identifier with the required destination and issues the transport decision. The 18 ms UID access value is typical; commissioning establishes actual tag orientation, useful reading distance and station dwell rather than treating that value as a complete routing-cycle guarantee.
Problem Solved
A carrier identifier gives external routing software a reference for selecting the next destination, helping associate the physical carrier with its stored production order.
UID identification
Carrier routing
13.56 MHz
2. Recording a completed operation in writable tag memory
An assembly station can write an operation code into a writable block on the carrier’s compatible transponder after external process logic confirms completion. The reader supports read/write access, with a typical 16 ms single-block write time for four bytes. External software defines the memory layout and reads back the record; actual tag permissions, station dwell and communication timing determine the implemented transaction.
Problem Solved
Writing and checking an operation record on the carrier tag lets downstream software recover a local progress reference as the carrier moves between assembly stations.
Writable tag record
Assembly progress
Four-byte block
3. Loading a fixture recipe reference at changeover
A changeover station can read a recipe reference from compatible tag memory on a presented fixture and pass it to external setup software. Reading multiple blocks supports a structured record, with 112 bytes read in a typical 64 ms for the specified 28-block access. External software validates the record and selects its approved machine parameters while commissioning accounts for tag placement and actual transaction duration.
Problem Solved
A structured fixture record supplies external setup software with a recipe reference, helping associate the presented tooling with the approved parameters for the next production run.
Fixture recipe
28-block read
External setup