SICK 1066554 GRL18-P1137 PNP Retro-reflective Sensor

USD 53.04

PNP complementary outputs, 650 nm red PinPoint LED, 0.06–6 m sensing with PL80A, 270° sensitivity adjustment and 2 m PVC cable; ABS housing and IP67.

SKU SICK-1066554 Category
SICK GR18

SICK GRL18-P1137 PNP Retro-reflective Sensor

BrandSICK
Model IdentifierGRL18-P1137
Official Part Number1066554

Technical Overview

The SICK GRL18-P1137 is an axial M18 photoelectric retro-reflective sensor with a dual-lens system and polarization filter. Its 650 nm visible red PinPoint LED provides a 0.06–6 m sensing range with a PL80A reflector, with maximum range of 0.03–7.2 m and a 175 mm spot at 7 m. A 270° potentiometer adjusts sensitivity, while complementary PNP outputs support light/dark switching through a 2 m four-wire PVC cable. Response is below 500 µs with a resistive load, with 1,000 Hz switching at a 1:1 light/dark ratio. The ABS plastic housing provides IP67 protection. Supply is 10–30 V DC; output-current and operating-temperature limits depend on voltage and ambient conditions.

M18 polarized red LED retro-reflective sensor with complementary PNP outputs, 0.06–6 m PL80A range, sensitivity adjustment and 2 m four-wire PVC cable.

Key Features

  • Dual-lens retro-reflective sensing with minimum reflector distance and polarization filter
  • 650 nm visible red PinPoint LED; Ø175 mm light spot at 7 m
  • 0.06–6 m sensing range with PL80A; maximum 0.03–7.2 m
  • 270° sensitivity potentiometer; separate power and received-light indicators
  • PNP complementary outputs; light/dark switching
  • <500 µs resistive-load response; 1,000 Hz at 1:1 light/dark ratio
  • M18 ×1 axial cylindrical housing; 2 m four-wire PVC cable
  • 10–30 V DC; 30 mA consumption; ≤100 mA output with stated derating
  • ABS plastic housing; PMMA optics; IP67
  • Two fastening nuts supplied: plastic; 22 mm across flats

Adjust the reflector-returned red beam and use complementary PNP states to report opaque-material interruptions to external machine control.

Technical Specification Matrix

ParameterValue
Functional principlePhotoelectric retro-reflective sensor; dual-lens system with minimum reflector distance
Mounting threadM18 × 1; cylindrical housing, axial optical axis
Sensing range0.06–6 m with PL80A reflector
Maximum sensing range0.03–7.2 m with PL80A reflector
Range with P250 reflector0.06–5.4 m sensing range; 0.03–6.4 m maximum range
Ranges with other reflectorsPL40A: 0.06–5.2 m sensing / 0.03–6.2 m maximum; PL20A: 0.06–2.9 m / 0.03–3.8 m; PL22: 0.06–1.9 m / 0.03–2.2 m; REF-Plus 3436 tape: 0.08–1.6 m / 0.06–2.0 m
Light source650 nm visible red PinPoint LED
Light spot sizeØ175 mm at 7 m; diagram also gives Ø8 mm at 0.2 m, Ø25 mm at 1 m and Ø75 mm at 3 m
Average LED service life100,000 h at ambient +25 °C
Polarization filterProvided
AdjustmentSensitivity potentiometer, 270°
IndicatorsGreen: power on; yellow: on when object absent, off when object present
Switching outputPNP
Output functionComplementary Q and Q complement
Switching modeLight/dark switching
Signal voltage HIGH/LOWVs − (≤3 V) / approximately 0 V
Output current≤100 mA; maximum 50 mA when supply >24 V or ambient temperature >49 °C
Response time<500 µs; signal transit time with resistive load
Switching frequency1,000 Hz at light/dark ratio 1:1
Connection2 m four-wire PVC cable
Pin assignmentCD-094: BN=L+; WH=Q complement; BU=M; BK=Q
Power supply10–30 V DC; limit values; short-circuit-protected network, maximum 8 A
Ripple<5 Vpp; supply must remain within voltage tolerances
Current consumption30 mA
Circuit protectionA: supply reverse-polarity protection; B: input/output reverse-polarity protection; D: output overcurrent and short-circuit protection
Protection classIII
Housing materialABS plastic
Optics materialPMMA plastic
IP ratingIP67
Items suppliedTwo fastening nuts, plastic; 22 mm across flats
Axial drawing length71.5 mm body and cable-exit length; flexible cable excluded
EMCEN 60947-5-2
Operating temperature−25 to +55 °C at supply ≤24 V and output current <50 mA
Storage temperature−40 to +70 °C
UL fileE348498
Certificates listedEU, UK, ACMA and Moroccan declarations of conformity; China RoHS; CCC exempt; ECOLAB; cULus; DIN EN 62471 photobiological safety
Cable bending conditionDo not bend below 0 °C

Industrial Applications

1. Counting separated opaque cartons on a conveyor

A packaging conveyor can position the sensor and reflector on opposite sides of the carton path. Each opaque carton interrupts the returned red beam, providing a PNP switching transition to an external counter. Carton length, spacing and conveyor speed are assessed against the response time below 500 µs and 1,000 Hz switching rating. The installed reflector and distance determine the available sensing range.

Problem Solved

Beam-interruption events give external counting logic a passage reference for separated cartons, allowing production totals to follow actual material movement without a contacting switch.

Carton passage External counting 1,000 Hz

2. Monitoring continuity of an opaque material web

A converting station can place an opaque web across the sensor-to-reflector path so normal material blocks the returned beam. A break or open gap restores the received-light condition, changing the complementary PNP outputs for external process logic. The potentiometer sets sensitivity during representative trials, and the green power indicator and yellow received-light indicator provide separate local checks of supply and beam state.

Problem Solved

A change between blocked and restored reflector light provides external process logic with a web-continuity reference, helping distinguish normal opaque material coverage from an open optical path.

Web continuity Complementary outputs Received-light indication

3. Timing prolonged occupancy at a transfer point

A material-transfer station can aim the sensor at a reflector behind a location that should clear after each opaque package moves onward. External logic times the PNP beam-blocked state and compares its duration with the normal transfer sequence. The M18 thread and supplied fastening nuts support fixed alignment, while the 2 m four-wire PVC cable carries supply and complementary signals to the controller.

Problem Solved

A persistent interrupted-beam condition gives external transfer logic an occupancy-duration reference, helping identify material that remains at the monitored transfer location beyond its expected dwell.

Transfer dwell External timing M18 mounting