SICK 1071853 IQ40-40NPOKK0S PNP NC Inductive Sensor

USD 64.48

Non-flush rectangular inductive sensor with 40 mm nominal range, 32.4 mm assured range, PNP normally-closed output, 100 Hz and cable-gland wiring.

SKU SICK-1071853 Category
SICK IQG

SICK IQ40-40NPOKK0S PNP NC Inductive Sensor

BrandSICK
Model IdentifierIQ40-40NPOKK0S
Official Part Number1071853

Technical Overview

The SICK IQ40-40NPOKK0S is a standard-design rectangular inductive proximity sensor for non-flush installation. It provides a 40 mm nominal sensing range and 32.4 mm assured range, with material-dependent reduction factors. The normally-closed PNP output uses a DC three-wire circuit and supports 100 Hz switching with continuous current up to 200 mA. The cable-gland connection accepts conductors up to 2.5 mm². PA66 housing and sensing face provide IP67/IP68/IP69K protection for operation from −25 to +85 °C. The 10–30 V DC electronics draw 12.5 mA without load, and yellow output-state and green operational LEDs assist local inspection.

Non-flush rectangular inductive sensor with 40 mm nominal range, PNP normally-closed output, 100 Hz and cable gland.

Key Features

  • Non-flush rectangular inductive sensing; standard design
  • 40 mm nominal range; 32.4 mm assured range
  • PNP normally closed (NC); DC three-wire
  • 100 Hz switching; continuous output current ≤200 mA
  • Cable gland; conductor size ≤2.5 mm²
  • 10–30 V DC; 12.5 mA no-load current
  • Short-circuit and power-up pulse protection
  • PA66 housing and sensing face; IP67/IP68/IP69K
  • −25 to +85 °C operation; maximum tightening torque 1.8 Nm
  • Yellow output-state LED and green operational LED

Detect metal targets across a 40 mm nominal non-flush gap and provide a normally-closed PNP signal to external machine control.

Technical Specification Matrix

ParameterValue
Functional principleInductive proximity sensing
Housing designRectangular, standard design
InstallationNon-flush
Nominal sensing range Sn40 mm
Assured sensing range Sa32.4 mm
Switching outputPNP
Output functionNormally closed (NC)
Electrical wiringDC three-wire
Switching frequency100 Hz
ConnectionCable gland
Terminal assignmentCD-341: 1=L+; 2=NC output; 3=M; 4=not connected
Power supply10–30 V DC
Voltage drop≤2 V
Time delay before availability≤50 ms
Hysteresis3–15% of Sr
Reproducibility≤6%
Temperature drift of Sr±10%
Continuous current≤200 mA
No-load current12.5 mA
Protective functionsShort-circuit protection; power-up pulse protection
Housing materialPA66 plastic
Sensing-face materialPA66 plastic
Tightening torqueMaximum 1.8 Nm
Protection classII; reference voltage 50 V DC
IP ratingIP67 / IP68 / IP69K
Operating temperature−25 to +85 °C
Storage temperature−40 to +85 °C
Shock resistance30 g, 11 ms
Vibration resistance10–55 Hz, 1 mm
Material reduction factorsApproximate reference values which may vary: V2A/304 stainless steel 0.8; aluminum 0.34; copper 0.27; brass 0.38
Installation clearancesManufacturer installation diagram keys: A=42 mm; B=150 mm; C=40 mm; D=120 mm; E=40 mm; F=150 mm
Mounting holesØ5.5 mm
IndicationYellow output-state LED; green operational-status LED
Manufacturer application areasDifficult application conditions
UL fileE348498
MTTFD1,125 years
DCavg0%
Mission time20 years
Cable-gland designationM20 1.5, as specified by manufacturer
Conductor size≤2.5 mm²
Dimensions L x W x H (cm)11.8 x 4 x 4

Industrial Applications

1. Confirming a metal carriage at a transfer position

A transfer mechanism can present a metal carriage target beside the non-flush sensing face at its intended stop. The PNP switching condition reports target position to external sequence logic. Setup accounts for the 40 mm nominal and 32.4 mm assured ranges, actual target material and geometry, and the documented clearances around the sensing location.

Problem Solved

A discrete metal-target reference gives external transfer logic a carriage-position condition, helping coordinate a dependent handover when the mechanism reaches its intended stop.

Carriage position 40 mm nominal PNP output

2. Counting metal tabs on a rotating mechanism

A rotating mechanism can carry separated metal tabs past the sensing face and feed PNP transitions to external counting logic. The 100 Hz switching rating provides the basis for assessing tab passage rate and spacing. Installation holds the commissioned gap within the suitable target range and preserves the documented non-flush clearances around the housing.

Problem Solved

Repeated metal-target transitions provide external counting electronics with cycle or passage events, helping track mechanism movement through a stationary inductive sensing point beside the tabs.

Metal-tab count 100 Hz External counter

3. Monitoring metal stock at a feeder reference

A metal-feeding station can mount the sensor beside a location normally occupied by incoming stock. Its switching condition changes when material leaves the sensing region, and external logic times that absence against the expected feed sequence. Actual stock material and cross-section guide the commissioned gap using the assured range and approximate reduction factors.

Problem Solved

A sustained target-absence condition supplies external feed monitoring with a stock-continuity reference, helping identify missing metal at the monitored location before the next process step.

Stock continuity External timing Metal sensing
Select your currency