SICK 6027339 L40S-21MA1A M18 Safety Single-Beam Sender

USD 156.78

M18 axial sender with 16 m stated range, 30 mm detection capability, straight M12 connection, IP67 and nickel-plated brass housing; separate UE401 required.

SKU SICK-6027339 Category
SICK L4000 Systems

SICK L40S-21MA1A M18 Safety Single-Beam Sender

BrandSICK
Model IdentifierL40S-21MA1A
Official Part Number6027339

Technical Overview

The SICK L40S-21MA1A is the M18 axial sender in an L4000 safety photoelectric switch system. It works with a separate matching optical component and the mandatory UE401 evaluation device; Type 4, SIL 3, Category 4 and PL e apply only to that combination. The exact datasheet states 16 m scanning range and 30 mm detection capability, while the manual distinguishes 10 m typical from 16 m maximum axial range. Its 660 nm visible red LED has a TE input for controlled channel testing and an emission indicator. The 19.2–28.8 V DC device uses a nickel-plated brass housing, glass front, straight M12 four-pin connection and IP67 protection.

M18 axial safety-system sender with 16 m stated range, 30 mm detection capability and straight M12 connection; matching optics and UE401 required.

Key Features

  • L4000 M18 axial sender; separate matching optical component
  • Safety operation requires UE401 evaluation device
  • Type 4 / SIL 3 / Category 4 / PL e only with UE401
  • 16 m stated range; manual 10 m typical, 16 m maximum axial range
  • 30 mm detection capability; one beam
  • 0.4 ms sensor response plus UE401 response
  • 660 nm visible red LED; TE-controlled emission
  • Emission LED for source-side observation
  • Straight M12 four-pin connector; nickel-plated brass housing and glass front
  • IP67; 19.2–28.8 V DC; −20 to +55 °C operation

Use the sender TE input and emission indication to support optical-channel testing in the required UE401 safety-system combination.

Technical Specification Matrix

ParameterValue
Product functionSender for L4000 safety photoelectric switch system; separate matching optical component and UE401 required
Matching optical componentL40E-21MA1A receiver, part 6027340
Protective-system requirementSafety operation only with UE401-A0010 evaluation device, part 6027343; sensor is not a standalone protective switching system
Scanning range16 m stated in exact-model datasheet; manual gives axial range 0–10 m typical, 0–16 m maximum
Number of beamsOne
Detection capability30 mm
Optical axisAxial
Response time0.4 ms sensor response plus UE401 test-device response for the protective system
Directional receiver responseManual typical LOW→HIGH 0.4 ms; HIGH→LOW 0.6 ms
Safety typeType 4, IEC 61496-1; only in conjunction with UE401
Safety integrity levelSIL 3, IEC 61508; only in conjunction with UE401
Safety categoryCategory 4, EN ISO 13849; only in conjunction with UE401
Performance levelPL e, EN ISO 13849; only in conjunction with UE401
PFHD2.9 × 10⁻¹⁰ per hour, EN ISO 13849; only in conjunction with UE401
Mission time20 years, EN ISO 13849; only in conjunction with UE401
ConnectionStraight M12 four-pin male connector
Pin assignment1=24 V DC; 2=not connected; 3=0 V; 4=TE sender test input
Power supply24 V DC nominal, 19.2–28.8 V DC
Current consumption≤60 mA; manual specifies this maximum for continuous sending during alignment
Protection classIII, IEC 61140
Housing designCylindrical, M18 × 1
Axial length97.7 mm including straight connector, as drawn
Housing materialNickel-plated brass
Front screen materialGlass
Optical aperture / receiving angle±2.5° / ±2.5°
Optics diameter12 mm typical in manual
IP ratingIP67, EN 60529
Operating temperature−20 to +55 °C
Storage temperature−25 to +75 °C
Relative humidity15–95%, non-condensing
Vibration resistance5 g, 10–55 Hz; IEC 60068-2-6
Shock resistance10 g, 16 ms; IEC 60068-2-27
Restart controlRestart interlock required in the L4000 system or machine; beam interruption does not establish continued occupancy
Detection limitsTransparent objects are not detected; beam system does not provide protection against thrown parts or emitted radiation
Functional inspectionDaily or before work begins: opaque test piece at least 30 mm diameter interrupts each beam at the documented test positions; receiver LED off and UE401 stop condition required
Light source660 nm visible red LED
Test input TEHIGH=transmission inactive; LOW or open circuit=transmission active
Sender indicationLED illuminates when sender is emitting
Physical Weight (kg)0.067

Industrial Applications

1. Providing an optical channel at a machine access opening

A machine access opening can position this sender opposite its matching optical component and connect the channel to the required UE401 evaluation device. Mechanical guarding directs entry through the beam arrangement at the required safety distance. The completed protective system uses restart interlock so that clearing the beam cannot itself authorize restart while someone remains inside the hazardous area.

Problem Solved

An evaluated beam-interruption channel gives the complete protective system an access event for its stopping function, with restart control provided by the documented system arrangement.

Access protection Separate UE401 Restart interlock

2. Exercising the optical channel through the sender test input

The UE401 evaluation device can control the sender TE input while monitoring the associated receiver channel. A HIGH input suppresses transmission, while LOW or an open circuit permits emission. This controlled change exercises the optical path and receiver response as part of the documented L4000 combination, rather than relying only on interruptions caused by actual access events.

Problem Solved

Controlled emission changes give the evaluation device a test stimulus through the optical channel, supporting response monitoring within the documented sender, receiver and UE401 combination.

TE test input Optical channel test UE401 evaluation

3. Checking emission while restoring optical alignment

During alignment or maintenance, qualified personnel can observe the sender LED to establish whether the source is emitting. The visible red beam supports alignment with the matching receiver, whose received-light indication completes the local assessment. Alignment is carried out with dangerous machine operation prevented, followed by the documented protective-system functional checks before operation resumes.

Problem Solved

Local emission indication provides a source-side observation during optical-path restoration, helping maintenance distinguish sender activity from the separate receiver alignment and channel evaluation results.

Emission indication Visible red LED Alignment maintenance
Select your currency