SICK 1062011 RE13-SA05 Two-NO Magnetic Safety Switch

SICK 1062011 RE13-SA05 Two-NO Magnetic Safety Switch

USD 68.38

RE13-SA05 sensor with actuator offers two NO reed contacts, 7 mm assured switch-on, 20 mm switch-off, 5 m PVC cable and IP67.

SKU: SICK-1062011 Category:
SICK Safety Switches

SICK RE13-SA05 Two-NO Magnetic Safety Switch

BrandSICK
Model IdentifierRE13-SA05
Official Part Number1062011

Technical Overview

The SICK RE13-SA05 is a non-contact magnetic safety switch supplied as a sensor with actuator. It provides two normally-open reed contacts, with no normally-closed or separate signaling contacts, and specifies assured switch-on and switch-off distances of 7 mm and 20 mm. The Type 4 interlocking device has a low actuator coding level according to EN ISO 14119. It connects through a 5 m PVC cable with flying leads, using 0.25 mm² copper conductors. Its rectangular VISTAL housing provides IP67 protection and −30 to +60 °C operation. Fault detection is performed by connected safety-related logic; this switch has no internal fault detection and supports individual diagnostic wiring rather than safe series connection.

Magnetic safety sensor with actuator, two NO reed paths, 7 mm switch-on and 20 mm switch-off distances, and 5 m PVC cable with flying leads.

Key Features

  • Non-contact magnetic sensor with actuator
  • Two normally-open reed contacts; no NC or signaling contacts
  • Assured switch-on 7 mm; assured switch-off 20 mm
  • One active sensor surface; five actuation directions
  • Type 4 interlocking device; low coding level according to EN ISO 14119
  • B10d: 2 × 10⁷ switching cycles with small load
  • External safety-related logic performs fault detection; individual wiring only
  • 5 m PVC cable with flying leads; 0.25 mm² copper conductors
  • Switching voltage ≤30 V DC; switching current ≤100 mA
  • Rectangular VISTAL housing; IP67; −30 to +60 °C operation

Monitor a movable guard through two magnetically actuated reed-contact paths and evaluate their sequence in connected safety-related logic.

Technical Specification Matrix

ParameterValue
System partMagnetic sensor with actuator
Sensor principleMagnetic non-contact actuation
Output typeReed contacts
Normally-open contacts2
Normally-closed contacts0
Signaling contacts0
Assured switch-on distance Sao7 mm
Assured switch-off distance Sar20 mm
Active sensor surfaces1
Actuation directions5
B10d2 × 10⁷ switching cycles with small load
Interlocking device typeType 4 according to EN ISO 14119
Actuator coding levelLow coding level according to EN ISO 14119
Fault detectionNo internal fault detection; switch cannot assume a safe state on fault; connected safety-related logic performs fault detection
Safe series connectionNone; individual wiring with diagnostics only
Connection5 m PVC cable with flying leads
Cable materialPVC
Cable length5 m
Cable diameter5.8 mm
Conductor materialCopper
Conductor cross-section0.25 mm²
Cable bend radiusFixed installation >12 × cable diameter; moving cable >15 × cable diameter
Contact pathsBN/brown to WH/white: normally open; BU/blue to BK/black: normally open
Monitored contact sequenceThe two contact paths are evaluated by connected safety logic; the manufacturer timing diagram identifies a channel sequence to be monitored
Switching voltage≤30 V DC
Switching current≤100 mA
Housing designRectangular
Housing materialVISTAL®
Body height36 mm
Body depth13 mm
Mounting hole detailØ4.5 mm through holes; Ø8.5 mm counterbores, 5 mm deep; 22 mm hole spacing
IP ratingIP67 according to IEC 60529
Operating temperature−30 to +60 °C
Storage temperature−30 to +60 °C
Vibration resistance10–55 Hz, 1 mm according to EN 60947-5-3
Shock resistance30 g, 11 ms according to EN 60947-5-3
Physical Weight (kg)0.3

Industrial Applications

1. Interlocking a movable machine guard

A movable guard can carry the supplied magnetic actuator opposite the fixed sensor. On closure, the actuator enters the defined switch-on region and the two normally-open reed paths provide inputs to suitable external safety logic. Opening separates the components toward the assured switch-off distance; the connected safety circuit evaluates the contact sequence and ends the hazardous machine state.

Problem Solved

Non-contact magnetic actuation gives the external safety circuit a guard-position input, helping interrupt controllable hazardous operation when the monitored guard is moved from its closed position.

Guard interlock Magnetic actuator Two NO paths

2. Evaluating the two contact channels independently

An installation with individual diagnostic wiring can route the brown/white reed path and blue/black reed path separately to a compatible safety-related logic unit. That unit evaluates the manufacturer’s channel sequence rather than treating the switch as a self-monitoring electronic safety output. The contact circuit is designed within the documented 30 V DC and 100 mA switching limits.

Problem Solved

Separate contact inputs let connected safety logic evaluate channel behavior, supporting fault detection outside a magnetic switch that has no internal diagnostic function of its own.

Individual wiring External diagnostics Reed channels

3. Validating actuator alignment during commissioning

During commissioning or guard maintenance, a technician can inspect the relative sensor and actuator positions through the intended opening and closing travel. The documented 7 mm assured switch-on and 20 mm assured switch-off distances provide reference bounds, while the response-range diagram guides assessment of lateral offset. External safety logic observes both contact paths during the installed movement.

Problem Solved

Defined actuation bounds support evaluation of the installed guard geometry, helping identify misalignment or excessive closed-position separation before the machine resumes its operating sequence.

Actuator alignment 7 mm on 20 mm off