| Functional principle | Incremental rotary encoder |
| Pulses per revolution | 512; observe the manufacturer speed/frequency limits |
| Measuring step | 90° electrical / pulses per revolution |
| Measuring-step deviation | ±0.008° for this binary pulse count |
| Error limits | ±0.05° |
| Electrical interface | HTL / push-pull |
| Signal channels | Six: A, complement A, B, complement B, Z and complement Z |
| Reference signal | One Z reference per revolution; 90° electrical, logically gated with A and B |
| Initialization time | 40 ms |
| Output frequency | ≤600 kHz; operating speed also limited by the selected pulse count and mechanical rating |
| Load current | ≤30 mA |
| Power supply | 10–32 V |
| Connection | 1.5 m eight-wire universal cable |
| Mechanical design | 10 mm through hollow shaft with front clamp |
| Shaft diameter | 10 mm F7 hollow-shaft bore |
| Shaft material | Stainless steel |
| Flange material | Aluminum |
| Housing material | Die-cast aluminum |
| Start-up torque | 0.8 Ncm at +20 °C |
| Operating torque | 0.6 Ncm at +20 °C |
| Operating speed | ≤6,000 rpm; observe output-frequency limit and speed-dependent self-heating allowance |
| Self-heating allowance | Allow 3.3 K per 1,000 rpm when designing the operating temperature range |
| Rotor moment of inertia | 40 gcm² |
| Bearing lifetime | 3.6 × 10^10 revolutions |
| Angular acceleration | ≤500,000 rad/s² |
| IP rating | IP65 on housing and shaft sides; IEC 60529 |
| Operating temperature | −40 to +100 °C with stationary cable; −30 to +100 °C with flexible cable; account for speed-dependent self-heating |
| Storage temperature | −40 to +100 °C, without packaging |
| Relative humidity | 90%, condensation not permitted |
| Shock resistance | 70 g, 6 ms; EN 60068-2-27 |
| Vibration resistance | 30 g, 10–2,000 Hz; EN 60068-2-6 |
| EMC | EN 61000-6-2 and EN 61000-6-4 |
| MTTFD | 300 years; EN ISO 13849-1. Standard product, not a safety component; nominal component load, average ambient +40 °C, 8,760 h/year, all electronic failures considered hazardous |
| Power consumption | ≤0.5 W without load |
| Reverse-polarity protection | Provided |
| Output short-circuit protection | Opposite another channel, supply US or GND for a maximum of 30 s |
| Permissible static movement | ±0.3 mm radial; ±0.5 mm axial |
| Permissible dynamic movement | ±0.1 mm radial; ±0.2 mm axial |
| Cable routing | Universal outlet supports radial or axial cable routing without bending at the outlet |
| Cable diameter | 5.6 ±0.2 mm; bend radius 30 mm |
| Wire assignment | WH=A; BN=complement A; PK=B; BK=complement B; VT=Z; YE=complement Z; BU=GND; RD=+US |
| Physical Weight (kg) | 0.2 |