1. Evaluating cylinder stop positions through digital position data
A cylinder-driven fixture can send its measured position through an IO-Link master to external machine logic. The controller compares the settled value with a commissioned process window within the 32 mm measuring range. The 16-bit position scale defines data interpretation, while the typical 0.3 mm linearity specification and actual cylinder mechanics determine appropriate acceptance bands.
Problem Solved
Digital position data gives external fixture logic a process-window reference around the intended stop, helping distinguish acceptable travel from a displaced settled position without an analog conversion stage.
Digital position window
IO-Link COM2
32 mm range
2. Applying a measuring-range setup during machine changeover
A machine with a compatible IO-Link master can teach or reset the sensor measuring range through its interface when changing the cylinder process setup. Key lock is also available through IO-Link, and the local button provides a factory-range reset. External setup logic manages these documented functions while the sensor remains connected through its M12 cable.
Problem Solved
Interface-based range teaching and reset give machine setup logic a consistent adjustment path, helping apply a measuring configuration and manage local control access during changeover.
Range changeover
IO-Link teaching
Key lock
3. Recording cylinder motion to identify a stalled travel event
External machine logic can collect successive IO-Link position words during a commanded cylinder movement and compare progress with elapsed time. A sustained plateau before the intended endpoint becomes a process-monitoring condition. The 2.3 ms communication cycle provides the interface timing reference, with the master scan and physical cylinder response included when assessing the recorded motion.
Problem Solved
Successive digital position values give external process monitoring a travel history, helping identify sustained lack of movement before the expected endpoint and support investigation of a stalled move.
Motion history
2.3 ms cycle
Stall monitoring