SICK 1056430 S32B-3011BA S300 Mini Safety Laser Scanner

USD 2,960.10

S32B-3011BA provides a 3 m protective field, 270° scanning, one triple field set, two OSSDs, CDS configuration and IP65 protection for indoor use.

SKU SICK-1056430 Category
SICK S300 Mini

SICK S32B-3011BA S300 Mini Safety Laser Scanner

BrandSICK
Model IdentifierS32B-3011BA
Official Part Number1056430

Technical Overview

The SICK S32B-3011BA is an S300 Mini Standard safety laser scanner for indoor industrial use. It combines a 3 m protective field range with 270° scanning, one triple field set and one monitoring case. Two OSSDs provide the safety-control interface, while two universal I/Os offer configuration-dependent input and warning functions. Detection resolution is configurable at 30, 40, 50, 70 or 150 mm, and response time depends on the basic response and multiple-sampling setting. Restart interlock, external device monitoring and contour-as-reference functions support the machine protection design. The device uses PC-based CDS configuration through RS-232, a 250 mm M12 eight-pin connection cable and an IP65 die-cast aluminum housing.

Indoor S300 Mini Standard safety laser scanner with 3 m protective field range, 270° scanning, one triple field set and two OSSDs.

Key Features

  • 3 m protective field range; 270° scanning angle
  • One triple field set with three fields and one monitoring case
  • Two OSSDs; two universal I/Os with configuration-dependent functions
  • 30, 40, 50, 70 or 150 mm configurable resolution; 0.5° angular resolution
  • Type 3 to IEC 61496; SIL 2; Category 3 and PL d
  • Restart interlock, EDM, multiple sampling and contour as a reference
  • 80 ms stated response; actual response depends on sampling configuration
  • PC configuration with CDS; RS-232 diagnostics at 38.4 kBaud
  • 250 mm connection cable with M12 eight-pin male connector; 24 V DC nominal
  • 905 nm Class 1 pulsed laser; IP65 aluminum housing; indoor −10 to +50 °C operation

Configure one indoor protective and warning field set, then send intrusion conditions to machine safety control through two OSSDs.

Technical Specification Matrix

ParameterValue
Functional principleSafety laser scanner; electro-sensitive protective device
Product versionS300 Mini Standard
ApplicationIndoor industrial use
Protective field range3 m
Warning field range8 m at 15% reflectivity; warning fields are not for protecting people
Distance measuring range30 m; measured data output not available
Field configurationOne triple field set; three fields; one monitoring case
Scanning angle270°
Configurable resolution30, 40, 50, 70 or 150 mm
Angular resolution0.5°
Response time80 ms; depends on basic response time and multiple sampling
Protective-field supplement100 mm
Multiple sampling2–16, configurable
Automatic reset delay2–60 s, configurable
ESPE typeType 3 to IEC 61496
Safety integrity levelSIL 2 to IEC 61508
Safety categoryCategory 3 to EN ISO 13849
Performance levelPL d to EN ISO 13849
PFHD8.0 × 10⁻⁸ per hour
Mission time20 years to EN ISO 13849
Fault safe stateAt least one OSSD in the OFF state
Restart interlockYes
External device monitoringYes; available according to universal I/O configuration
Contour as a referenceYes
Safety outputsTwo output signal switching devices (OSSDs)
Universal I/OTwo configurable universal I/Os
Configurable input functionsEDM, reset/restart or standby; availability depends on universal I/O configuration
Other output functionsTwo warning-field outputs or reset-required signal; availability depends on universal I/O configuration
Measured data outputNone
ConfigurationPC with CDS (Configuration and Diagnostic Software)
Configuration/diagnostics interfaceRS-232; 38.4 kBaud
Connection250 mm cable with M12 eight-pin male connector
Power supply24 V DC nominal; 16.8–30 V DC range
Supply current0.25 A at 24 V DC without output load; 1.35 A including maximum output load
Protection classIII to EN 50178 and EN 60950
Housing materialDie-cast aluminum
Housing colorRAL 1021 yellow; RAL 9005 black
Optics coverPolycarbonate with outside scratch-resistant coating
Mounting threadM5 × 7.5 mm
IP ratingIP65 to EN 60529
Operating temperature−10 to +50 °C
Storage temperature−25 to +50 °C
Vibration resistanceIEC 60068-2-6; IEC 60068-2-64; IEC 60721-3-5; IEC TR 60721-4-5; IEC 61496-3; Class 5M1 to IEC 60721-3-5
Shock resistanceIEC 60068-2-27; IEC 60721-3-5; IEC TR 60721-4-5; IEC 61496-3; Class 5M1 to IEC 60721-3-5
Continuous shock50 m/s² for 11 ms; 100 m/s² for 16 ms
Light sourcePulsed laser diode
Wavelength905 nm
Laser classClass 1 to 21 CFR 1040.10/1040.11 and IEC 60825-1
Detectable remission factor1.8% to >1,000%, reflectors

Industrial Applications

1. Monitoring a horizontal indoor machine area

An indoor machine cell can use a horizontal protective field to detect a person entering or remaining in the monitored floor area. The scanner provides a 270° scan and a protective field range up to 3 m, with its two OSSDs connected to the machine safety control. The configured detection resolution, multiple sampling, protective-field supplement and complete machine stopping time determine the installed separation distance.

Problem Solved

Protective-field intrusion changes the OSSD condition for the machine safety control, supporting a stop demand and restart inhibition while the monitored indoor area is occupied.

Hazardous area 3 m protective field Two OSSDs

2. Detecting passage through an indoor access opening

A guarded indoor enclosure can use a vertically installed protective field across its access opening to detect whole-body passage. Contour-as-reference monitoring supports checking the configured opening boundary, while the two OSSDs provide the stop-demand interface to the safety control. This access arrangement detects crossing of the scan plane; a person standing beyond that plane requires the machine protection concept to account for that position.

Problem Solved

A monitored access plane supplies a stop-demand condition when a person crosses the opening, helping interrupt hazardous machine operation at the guarded entry.

Access opening Contour reference Whole-body passage

3. Monitoring the approach path of an indoor guided vehicle

An indoor guided vehicle can use this Standard variant with one configured triple field set and one monitoring case along its approach path. A protective-field intrusion supplies the OSSD stop demand, while warning fields can feed preliminary slowing or signaling logic. The protective field is limited to 3 m; vehicle speed, stopping performance, mounting geometry and configured sampling determine the usable protected travel condition.

Problem Solved

Separate protective and warning conditions let vehicle control distinguish a safety stop demand from preliminary approach information, supporting coordinated movement within the configured monitored path.

Indoor vehicle One monitoring case Separate warning fields