1. Monitoring a horizontal indoor machine area
An indoor machine cell can use a horizontal protective field to detect a person entering or remaining in the monitored floor area. The scanner provides a 270° scan and a protective field range up to 1 m, with its two OSSDs connected to the machine safety control. The configured detection resolution, multiple sampling, protective-field supplement and complete machine stopping time determine the installed separation distance.
Problem Solved
Protective-field intrusion changes the OSSD condition for the machine safety control, supporting a stop demand and restart inhibition while the monitored indoor area is occupied.
Hazardous area
1 m protective field
Two OSSDs
2. Detecting passage through an indoor access opening
A guarded indoor enclosure can use a vertically installed protective field across its access opening to detect whole-body passage. Contour-as-reference monitoring supports checking the configured opening boundary, while the two OSSDs provide the stop-demand interface to the safety control. This access arrangement detects crossing of the scan plane; a person standing beyond that plane requires the machine protection concept to account for that position.
Problem Solved
A monitored access plane supplies a stop-demand condition when a person crosses the opening, helping interrupt hazardous machine operation at the guarded entry.
Access opening
Contour reference
Whole-body passage
3. Monitoring the approach path of an indoor guided vehicle
An indoor guided vehicle can use this Standard variant with one configured triple field set and one monitoring case along its approach path. A protective-field intrusion supplies the OSSD stop demand, while warning fields can feed preliminary slowing or signaling logic. The protective field is limited to 1 m; vehicle speed, stopping performance, mounting geometry and configured sampling determine the usable protected travel condition.
Problem Solved
Separate protective and warning conditions let vehicle control distinguish a safety stop demand from preliminary approach information, supporting coordinated movement within the configured monitored path.
Indoor vehicle
One monitoring case
Separate warning fields