1. Confirming a metal target at a compact transfer stop
A compact transfer stop can present a metal carrier target at a controlled gap in front of the flush M8 sensing face. The PNP normally-open output connects to external sequencing logic. Setup checks the target material and geometry against the 1.5 mm nominal range and listed material reduction factors before using the signal as a carrier-arrival condition.
Problem Solved
A discrete metal-target reference helps external transfer logic recognize arrival at a compact stop and coordinate the next handling operation using the PNP input state.
Compact arrival check
M8 mounting
PNP signal
2. Counting separated metal tabs on a moving mechanism
A rotating or translating mechanism can present separated metal tabs to the sensor and send PNP transitions to an external counter. The 3,000 Hz switching specification provides the sensor timing basis. Commissioning checks tab size, material, gap and passage timing so that each target produces a distinct transition at the installed sensing location.
Problem Solved
Distinct metal-tab transitions give external counting logic passage events from one sensing point, helping track mechanism cycles while keeping evaluation and counting in the controller.
Metal-tab counter
3,000 Hz
PNP transitions
3. Checking a metal insert in an assembly fixture
An assembly fixture can present a metal insert at a repeatable gap in front of the flush-mounted sensor. External inspection logic samples the PNP normally-open signal after the part settles. Setup verifies the insert material, presentation tolerance and surrounding-metal arrangement, using the listed reduction factors and reproducibility conditions when assessing the inspection position.
Problem Solved
A metal-insert presence condition helps external inspection logic identify an empty assembly location before processing continues, using a compact threaded sensing point in the fixture.
Insert presence
Assembly inspection
Material factors