SICK 1059746 RZC1-04ZRS-KU0 C-slot Reed Cylinder Sensor

USD 31.20

RZC1-04ZRS-KU0 detects C-slot cylinder magnets with a normally-open reed output, 5–30 V AC/DC supply, 500 Hz switching, 2 m PUR cable and IP68/IP69K.

SKU SICK-1059746 Category
SICK RZC1

SICK RZC1-04ZRS-KU0 C-slot Reed Cylinder Sensor

BrandSICK
Model IdentifierRZC1-04ZRS-KU0
Official Part Number1059746

Technical Overview

The SICK RZC1-04ZRS-KU0 is a magnetic cylinder sensor for C-slot installation, using a normally-open reed output and AC/DC three-wire wiring. It operates from 5–30 V AC/DC, with a 500 Hz switching specification, continuous current up to 500 mA and switching capacity up to 10 W. Its typical 7 mm overrun distance describes magnet travel while the switching signal is present. A status LED assists local observation, and the 26.3 mm strengthened-PA housing is secured with an AF 1.5 screw at a typical 0.5 Nm torque. The axial connection uses a 2 m stripped three-wire PUR cable. The device provides IP68/IP69K protection and −30 to +80 °C operation; suitable adapters support SMC CDQ2/ECDQ2 rails.

C-slot magnetic cylinder sensor with normally-open reed output, 5–30 V AC/DC wiring, 500 Hz switching and 2 m stripped three-wire PUR cable.

Key Features

  • Magnetic piston-position detection in C-slot cylinders
  • Normally-open reed output; AC/DC three-wire wiring
  • 5–30 V AC/DC supply; 5 mA consumption without load
  • 500 Hz switching frequency; continuous current ≤500 mA; switching capacity ≤10 W
  • Typical 7 mm overrun distance; reproducibility ≤0.1 mT at constant supply and temperature
  • 26.3 mm strengthened-PA housing; AF 1.5 fixing screw; typical 0.5 Nm torque
  • Axial 2 m stripped three-wire PUR cable
  • 0.09 mm² conductors; Ø2.2 mm cable; fixed bend >2D, flexible >5D
  • Status LED; suitable adapters for SMC CDQ2/ECDQ2 rails
  • IP68/IP69K; −30 to +80 °C operation; protection class III

Place a normally-open magnetic switching point in a C-slot cylinder and send the piston-magnet condition to the machine sequence through the three-wire connection.

Technical Specification Matrix

ParameterValue
Functional principleMagnetic cylinder sensing with reed switch
Cylinder typeC-slot
Cylinder types with adapterSMC rail CDQ2; SMC rail ECDQ2; suitable adapter required
Housing length26.3 mm
Housing width2.9 mm
Housing height4.7 mm
Sensor element position6.3 mm from housing tip, as shown in drawing
Switching outputReed; normally open
Electrical wiringAC/DC three-wire
Switching frequency500 Hz
Power supply5–30 V AC/DC
Current consumption5 mA without load
Voltage drop<0.5 V
Continuous current Ia≤500 mA
Switching capacity≤10 W
Protection classIII
Typical overrun distance7 mm: distance traveled by the magnet while the sensor outputs a switching signal
Overrun principleOverrun distance equals switching-point width plus hysteresis; depends on magnet travel direction
Reproducibility≤0.1 mT at constant supply voltage and ambient temperature
IndicationStatus LED
Teach-inNo
Connection2 m stripped three-wire PUR cable
Wiring assignmentCD-035: BN=L+/L1; BK=NO; BU=M/N
Conductor cross-section0.09 mm²
Cable diameter2.2 mm
Cable outletAxial
Bending radiusFixed installation >2 × cable diameter; flexible use >5 × cable diameter
Cable materialPUR
Housing materialStrengthened PA plastic
Mounting screwAF 1.5; typical tightening torque 0.5 Nm
IP ratingIP68 to EN 60529; IP69K to DIN 40050
Operating temperature−30 to +80 °C
Shock resistance30 g, 11 ms
Vibration resistance10–55 Hz, 1 mm
EMCEN 60947-5-2
UL fileNRKH.E181493 and NRKH7.E181493
MTTFDListed 41,230 years; entire-device MTTFD must be calculated from B10D, switching-cycle rate and the listed MTTFD
DCavg0%
Mission time20 years
B10D5,000,000 switching cycles; use with switching-cycle rate and listed MTTFD to calculate entire-device MTTFD

Industrial Applications

1. Confirming a cylinder at its transfer position

A transfer cylinder can use the C-slot sensor at a selected stroke position so that the piston magnet operates the normally-open reed signal. External sequencing logic reads that condition before requesting the next handling step. Setup adjusts and fixes the sensor position while checking the actual cylinder magnet, typical overrun distance and load against the electrical switching limits.

Problem Solved

A piston-position reference helps external transfer logic recognize the selected cylinder position and coordinate the following handling operation without measuring the full stroke continuously.

Cylinder sequence C-slot mounting Reed signal

2. Timing cylinder arrival after an actuation command

A pneumatic station can start an external timer when it commands a cylinder movement and stop that timer when the reed sensor reports arrival at the selected position. The C-slot mounting and normally-open signal establish the arrival reference. Commissioning checks actual piston-magnet behavior, travel direction and the 500 Hz specification against the station timing requirements.

Problem Solved

An arrival event gives external timing logic a repeatable endpoint for comparing command-to-arrival duration, helping identify a cylinder movement that takes longer than the configured process window.

Arrival timing External timer Position event

3. Counting repeated cylinder cycles for maintenance records

A machine can count transitions at a selected cylinder position in an external maintenance counter. The reed sensor supplies a normally-open event as the piston magnet passes its installed C-slot location. The counter validates the expected sequence to avoid counting repeated transitions as separate cycles, and setup respects the sensor switching frequency, current and power limits.

Problem Solved

Position events let external maintenance logic accumulate cylinder-cycle records, providing a usage reference for planned service while leaving counting and record storage in the controller.

Cycle counter Maintenance record External evaluation
Select your currency