SICK 1059743 MZC1-2V2NS-KU0 NPN C-slot Cylinder Sensor

USD 33.80

MZC1-2V2NS-KU0 offers NPN normally-open cylinder sensing, 1,000 Hz switching, a 2 m stripped three-wire PUR cable and IP68/IP69K protection.

SKU SICK-1059743 Category
SICK MZC1

SICK MZC1-2V2NS-KU0 NPN C-slot Cylinder Sensor

BrandSICK
Model IdentifierMZC1-2V2NS-KU0
Official Part Number1059743

Technical Overview

The SICK MZC1-2V2NS-KU0 is a magnetic cylinder sensor with an NPN normally-open output for C-slot installation. Its typical response sensitivity is 2.2 mT and typical overrun distance is 4 mm, describing magnet travel while the switching signal is present. The 10–30 V DC device provides 1,000 Hz switching, a status LED and reverse-polarity, short-circuit and power-up pulse protection. An axial 2 m stripped three-wire PUR cable connects the sensor to field wiring. The 23.7 mm plastic housing uses an AF 1.5 fixing screw at a typical 0.5 Nm torque. IP68/IP69K protection, −30 to +80 °C operation and suitable cylinder adapters support integration.

NPN normally-open C-slot magnetic cylinder sensor with 1,000 Hz switching, a 2 m stripped three-wire PUR cable and IP68/IP69K protection.

Key Features

  • Magnetic piston-position sensing in C-slot cylinders
  • NPN normally-open output; DC three-wire wiring
  • 10–30 V DC; 8 mA consumption without load; current ≤100 mA
  • 1,000 Hz switching; voltage drop ≤2.5 V; protection class III
  • Typical 2.2 mT response sensitivity; typical 4 mm magnet overrun distance
  • Reproducibility ≤0.1 mT at constant supply/temperature; typical hysteresis ≤0.8 mT
  • 23.7 mm plastic housing; AF 1.5 fixing screw at typical 0.5 Nm
  • 2 m axial stripped three-wire PUR cable; 0.09 mm² conductors; Ø2.2 mm cable
  • Reverse-polarity, short-circuit and power-up pulse protection; status LED
  • IP68/IP69K; −30 to +80 °C operation; suitable adapters for additional cylinder types

Place an NPN piston-position switching point in a C-slot cylinder and connect it to field wiring through a 2 m three-wire PUR cable.

Technical Specification Matrix

ParameterValue
Functional principleMagnetic cylinder sensing
Cylinder typeC-slot
Cylinder types with adapterSMC CDQ2/ECDQ2 rails; round-body cylinders; profile and tie-rod cylinders; suitable adapter required
Housing length23.7 mm
Housing width2.9 mm
Housing height4.7 mm
Sensor element position2.55 mm from housing tip, as shown in drawing
Switching outputNPN normally open
Electrical wiringDC three-wire
Switching frequency1,000 Hz
Power supply10–30 V DC
Current consumption8 mA without load
Voltage drop≤2.5 V
Continuous current Ia≤100 mA
Protection classIII
Typical overrun distance4 mm: distance traveled by the magnet while the sensor outputs a switching signal
Overrun principleOverrun distance equals switching-point width plus hysteresis; depends on magnet travel direction
Reproducibility≤0.1 mT at constant supply voltage and ambient temperature
IndicationStatus LED
Teach-inNo
Connection2 m stripped three-wire PUR cable
Wiring assignmentCD-001: BN=L+; BK=NO; BU=M
Conductor cross-section0.09 mm²
Cable diameter2.2 mm
Cable outletAxial
Bending radiusFixed installation >2 × cable diameter; flexible use >5 × cable diameter
Cable materialPUR
Housing materialPlastic
Mounting screwAF 1.5; typical tightening torque 0.5 Nm
IP ratingIP68; IP69K to DIN 40050
Operating temperature−30 to +80 °C
Shock resistance30 g, 11 ms
Vibration resistance10–55 Hz, 1 mm
EMCEN 60947-5-2
UL fileNRKH.E181493 and NRKH7.E181493
MTTFD2,461 years
DCavg0%
Mission time20 years
Typical response sensitivity2.2 mT
Typical hysteresis≤0.8 mT
Circuit protectionReverse-polarity protection; short-circuit protection; power-up pulse protection
Manufacturer low-voltage noteThe supply table specifies 10–30 V DC. Its footnote additionally states a 5 V minimum supply with no allowance for 10% residual ripple.

Industrial Applications

1. Confirming a cylinder at its transfer position

A transfer cylinder can use the C-slot sensor at a selected stroke position so that its piston magnet operates the NPN normally-open signal. External sequencing logic reads that condition before requesting the next handling step. Setup adjusts and fixes the sensor position, checking the actual cylinder magnet, typical 4 mm overrun distance and external input loading against the 100 mA current limit.

Problem Solved

A piston-position reference helps external transfer logic recognize the selected cylinder position and coordinate the following handling operation without measuring the full stroke continuously.

Cylinder sequence C-slot mounting NPN signal

2. Timing cylinder arrival after an actuation command

A pneumatic station can start an external timer when it commands a cylinder movement and stop that timer when the NPN sensor reports arrival at the selected position. The C-slot mounting and normally-open signal establish the arrival reference. Commissioning checks actual piston-magnet behavior, travel direction and the 1,000 Hz specification against the station timing requirements.

Problem Solved

An arrival event gives external timing logic a repeatable endpoint for comparing command-to-arrival duration, helping identify a cylinder movement that takes longer than the configured process window.

Arrival timing External timer Position event

3. Counting repeated cylinder cycles for maintenance records

A machine can count NPN transitions at a selected cylinder position in an external maintenance counter. The sensor supplies a normally-open event as the piston magnet passes its installed C-slot location. The counter validates the expected movement sequence to avoid counting repeated transitions as separate cycles, and setup respects the 1,000 Hz specification and 100 mA current limit.

Problem Solved

Position events let external maintenance logic accumulate cylinder-cycle records, providing a usage reference for planned service while leaving counting and record storage in the controller.

Cycle counter Maintenance record External evaluation
Select your currency