SICK 1070866 RZT7-03ZVO-KW0 NC Reed Cylinder Sensor

USD 36.14

RZT7-03ZVO-KW0 detects magnetic piston position in T-slot cylinders with a normally-closed reed output, 400 Hz switching, 5–120 V AC/DC supply and 2 m cable.

SKU SICK-1070866 Category
SICK RZT7

SICK RZT7-03ZVO-KW0 NC Reed Cylinder Sensor

BrandSICK
Model IdentifierRZT7-03ZVO-KW0
Official Part Number1070866

Technical Overview

The SICK RZT7-03ZVO-KW0 is a magnetic cylinder sensor with a normally-closed reed contact and AC/DC two-wire operation. Its 32.5 mm plastic housing fits a T-slot and is secured by an SW2.5 screw with typical 0.7 Nm tightening torque. Typical response sensitivity is 3 mT, typical overrun distance is 10 mm, and switching frequency is 400 Hz. The 5–120 V AC/DC device uses a 2 m stripped two-wire PVC cable. The supply requires a mains fuse below 0.8 A to IEC60127-2 sheet 1; fixed and flexible cable bend radii exceed ten and fifteen cable diameters respectively. IP65/IP67 protection and −30 to +70 °C operation support cylinder-mounted use; this model has no indicator LED or teach-in function.

T-slot magnetic cylinder sensor with a normally-closed reed output, 400 Hz switching, 5–120 V AC/DC operation and 2 m stripped two-wire PVC cable.

Key Features

  • Magnetic piston-position sensing for T-slot cylinders
  • Normally-closed reed contact; AC/DC two-wire electrical design
  • 400 Hz switching frequency; typical 3 mT response sensitivity
  • Typical 10 mm overrun distance; reproducibility ≤0.1 mT at constant supply and temperature
  • 5–120 V AC/DC; mains fuse <0.8 A to IEC60127-2 sheet 1; protection class II
  • Continuous current ≤100 mA AC/DC; switching capacity ≤6 W
  • 2 m stripped two-wire PVC cable
  • 32.5 mm Grilamid LVX-65H SST plastic housing; typical 0.7 Nm fixing torque
  • IP65/IP67; −30 to +70 °C operation
  • Axial cable outlet; fixed bend radius >10 × cable diameter, flexible >15 × diameter

Detect a cylinder piston magnet through a T-slot-mounted normally-closed reed contact and provide position transitions to external machine sequencing.

Technical Specification Matrix

ParameterValue
Functional principleMagnetic cylinder sensing with reed contact
Cylinder typeT-slot
Cylinder types with adapterProfile, tie-rod, round-body and dovetail-groove cylinders; SMC CDQ2 and ECDQ2 rail; appropriate adapter required
Housing length32.5 mm
Switching outputReed contact
Output functionNormally closed, NC
Electrical wiringAC/DC two-wire
Switching frequency400 Hz
Power supply5–120 V AC/DC; mains fuse F <0.8 A to IEC60127-2 sheet 1
Voltage drop≤3.5 V
Continuous current≤100 mA AC/DC
Switching capacity≤6 W
Protection classII
Response sensitivityTypical 3 mT
Overrun distanceTypical 10 mm; distance traversed by piston magnet while the sensor outputs a switching signal
Reproducibility≤0.1 mT at constant supply voltage and ambient temperature
Indicator LEDNone
Teach-inNone
Connection2 m stripped two-wire PVC cable
Cable outletAxial
Conductor cross-section0.12 mm²
Cable diameterØ2.9 mm
Bend radius, fixed installation>10 × cable diameter
Bend radius, flexible use>15 × cable diameter
Housing materialGrilamid LVX-65H SST plastic
Fixing screwSW2.5; typical tightening torque 0.7 Nm
IP ratingIP65 / IP67 to EN 60529
Operating temperature−30 to +70 °C
Shock resistance30 g, 11 ms
Vibration resistance10–55 Hz, 1 mm
EMCEN 60947-5-2
MTTFD167,567 years; for electromechanical devices, calculate whole-device MTTFD using B10D, switching-cycle count and this value
DCavg0%
Mission time20 years
B10D500,000 switching cycles; electromechanical component value, used with switching frequency of operation for whole-device MTTFD calculation
Rated insulation voltage Ui120 V
Rated impulse withstand voltage Uimp2.5 kV
Recommended mechanical protectionBEF-SG-MRZT, part number 2077201; recommended accessory, not stated as supplied

Industrial Applications

1. Confirming piston arrival before the next machine step

A pneumatic assembly can locate the sensor in a T-slot so that the piston magnet reaches its sensing element at the required end position. The normally-closed reed contact changes condition in the magnetic switching region. External sequence logic evaluates that transition before advancing the next process step, using the documented sensitivity and overrun behavior to establish sensor placement.

Problem Solved

A piston-position transition gives external sequencing logic an arrival reference, helping coordinate the following machine operation with the actuator reaching its selected end position.

Piston arrival T-slot mounting NC reed contact

2. Detecting an actuator that has not completed its stroke

A clamping station can place the reed sensor at the expected piston endpoint and start an external timer when motion is commanded. The controller watches for the normally-closed contact transition within the permitted process interval. If that transition is absent, the controller identifies a stroke-completion problem; the sensor supplies position state while the external controller performs the timing and fault decision.

Problem Solved

An endpoint signal compared with an external motion timer helps identify a stalled or incomplete cylinder stroke, supporting process fault handling before subsequent tooling advances.

Stroke timeout External timing Endpoint signal

3. Counting completed pneumatic actuator cycles

A production counter can record one selected transition each time a piston magnet passes the fixed sensing element during a completed actuator cycle. The 400 Hz switching rating and typical 10 mm overrun distance provide the sensor timing and magnetic travel basis. External counting logic distinguishes the selected arrival edge from the return stroke and checks the actual cylinder speed and magnetic field.

Problem Solved

Selected reed-contact transitions provide external counting logic with actuator-cycle events, helping track machine utilization or maintenance intervals from observed piston movement at a fixed sensing location.

Cycle count 400 Hz Magnetic travel