SICK 1062451 IQ08-02BNSKUDSS03 NPN NO Inductive Sensor

USD 113.10

Flush rectangular inductive sensor with 2 mm nominal range, NPN normally-open output, 2,000 Hz switching and a 0.85 m PUR cable with AMP connector.

SKU SICK-1062451 Category
SICK IQY

SICK IQ08-02BNSKUDSS03 Inductive Proximity Sensor

BrandSICK
Model IdentifierIQ08-02BNSKUDSS03
Official Part Number1062451

Technical Overview

The SICK IQ08-02BNSKUDSS03 is a rectangular inductive proximity sensor with a normally-open NPN output for noncontact metal detection. Its 2 mm nominal range and 1.62 mm assured range apply with flush mounting and the documented target-material reduction factors. The VISTAL® housing and sensing face provide IP67/IP68 protection, with M3 threaded mounting holes for machine integration. A 0.85 m PUR cable with an AMP connector provides the electrical interface. The sensor offers 2,000 Hz switching, availability within 100 ms, 10–30 V DC operation and output current up to 200 mA, across a −25 to +75 °C operating range.

NPN NO inductive sensor with 2/1.62 mm nominal/assured ranges, flush mounting, 2,000 Hz switching and 0.85 m PUR cable with an AMP connector.

Key Features

  • 2 mm nominal range; 1.62 mm assured sensing range
  • Flush installation; target-material factors apply
  • NPN normally-open output; DC three-wire
  • 2,000 Hz switching; availability ≤100 ms
  • 10–30 V DC; continuous output current ≤200 mA
  • VISTAL® housing and sensing face
  • IP67 and IP68 enclosure ratings
  • Two M3 threaded mounting holes; 20 mm pitch
  • 0.85 m PUR cable with AMP connector; pins 1 BN=L+, 4 BK=NO, 3 BU=M
  • −25 to +75 °C operation; maximum tightening torque ≤1.5 Nm

Integrate a flush metal-target reference into a compact fixture using two M3 mounting holes and a PUR cable with AMP connector.

Technical Specification Matrix

ParameterValue
Functional principleInductive metal proximity detection
Housing formRectangular
Body width8 mm; drawing side profile 8.1 mm
Sensing range Sn2 mm nominal
Assured sensing range Sa1.62 mm
InstallationFlush
Switching frequency2,000 Hz
Switching outputNPN
Output functionNormally open (NO)
Electrical wiringDC three-wire
Connection0.85 m PUR cable with AMP connector
Conductor assignmentCD-002: pin 1 BN=L+; pin 4 BK=NO output; pin 3 BU=M
Power supply10–30 V DC
Residual ripple≤10% of supply voltage
Voltage drop≤2 V at maximum output current Ia
Time delay before availability≤100 ms
Hysteresis5–15%
Reproducibility≤2% of Sr at constant supply voltage and ambient temperature
Temperature drift±10% of Sr
EMCAccording to EN 60947-5-2
Continuous output current≤200 mA
No-load current10 mA
Circuit protectionShort-circuit and power-up pulse protection
Shock resistance30 g, 11 ms
Vibration resistance10–55 Hz, 1 mm
Operating temperature−25 to +75 °C
Housing materialVISTAL® plastic
Sensing face materialVISTAL® plastic
Maximum tightening torque≤1.5 Nm
UL fileNRKH.E348498
MTTFD1,730 years
Diagnostic coverage DCavg0%
Mission time20 years
IP ratingIP67, IP68
Mounting holesTwo M3 threaded mounting holes; 20 mm pitch
Target-material reduction factorsApproximate reference values, may vary: V2A/304=0.7; aluminum=0.3; copper=0.2; brass=0.3
Mounting clearancesA=0 mm; B=10 mm; C=8 mm; D=6 mm; E=0 mm; F=16 mm; G=0 mm; follow manufacturer installation diagram
Cable materialPUR

Industrial Applications

1. Checking a metal component at a fixture

An assembly fixture can bring a qualified metal component near the sensor at a defined inspection point. The 2 mm nominal and 1.62 mm assured ranges guide placement with flush installation. The NPN normally-open output supplies the local presence condition, while target-material reduction factors and the mounting clearances determine the final component position.

Problem Solved

A noncontact metal-presence signal lets the external controller identify an empty monitored fixture position before the next operation, without requiring a contact probe against the component.

Component presence 1.62 mm assured NPN

2. Counting metal parts at a guided feeder

A guided feeder can present separated qualified metal parts across the sensing zone. An external counter reads the normally-open output transitions produced as each part passes. The 2,000 Hz switching frequency, 5–15% hysteresis and specified reproducibility guide spacing and event qualification, with the documented material reduction factors considered for the selected target.

Problem Solved

A part-passage event supports quantity tracking at the feeder exit without a counting lever touching the parts, while the external controller performs counting and regulates the feed sequence.

Metal-part counting 2,000 Hz External counter

3. Referencing a metal flag on a small mechanism

A moving mechanism can carry an intended metal flag past the sensing face at its reference station. Two M3 mounting holes at 20 mm pitch locate the rectangular body, while the PUR cable and AMP connector route its signal to the machine input. External sequencing reads the NPN normally-open transition with the documented flush mounting clearances maintained.

Problem Solved

A discrete metal-flag reference helps external sequencing coordinate a repeat mechanism cycle without a contact cam switch, using the established mounting position and ordinary switching input.

Flag reference M3 mounting AMP connection
Select your currency