SICK 1059407 GRTE18S-P2319 PNP Diffuse Sensor

USD 56.68

GRTE18S-P2319 offers 5–100 mm reference-white diffuse sensing, radial M18 optics, PNP light switching, 500 Hz operation and M12 three-pin connection.

SKU SICK-1059407 Category
SICK GR18S

SICK GRTE18S-P2319 PNP Diffuse Sensor

BrandSICK
Model IdentifierGRTE18S-P2319
Official Part Number1059407

Technical Overview

The SICK GRTE18S-P2319 is a short-body cylindrical energetic photoelectric proximity sensor with a radial optical axis and an M18 × 1 mounting thread. Its 5–100 mm sensing range and 3–115 mm maximum range apply to 90% remission reference white. A 650 nm red PinPoint LED forms an 8 mm spot at 100 mm, and a 270° potentiometer adjusts sensing range. A single PNP output provides fixed light switching through an M12 three-pin connector. Response is below 1,000 µs with resistive load, with 500 Hz switching at a 1:1 light/dark ratio. The IP67 ABS housing uses PMMA optics and includes two plastic fastening nuts. Output current is limited to 50 mA above 24 V supply or 49 °C ambient temperature.

Short M18 energetic sensor with radial optics, 5–100 mm reference-white sensing, fixed PNP light switching and M12 three-pin connection.

Key Features

  • Energetic photoelectric proximity sensing with radial optics
  • 5–100 mm sensing; 3–115 mm maximum range on 90% remission white
  • 650 nm red PinPoint LED; Ø8 mm spot at 100 mm
  • 270° sensing-range potentiometer
  • Single PNP output with fixed light switching
  • <1,000 µs resistive-load response; 500 Hz at 1:1 light/dark ratio
  • 10–30 V DC; output ≤100 mA, derated to 50 mA above 24 V or 49 °C
  • M12 three-pin male connector; short M18 × 1 ABS housing
  • PMMA optics; IP67; two plastic fastening nuts supplied
  • Green power LED and yellow object-presence LED

Adjust reflected-light detection from a radial M18 optical axis and provide a fixed PNP light-switching signal to external process control.

Technical Specification Matrix

ParameterValue
Functional principleEnergetic photoelectric proximity sensor
Housing designShort-body cylindrical; radial optical axis
Mounting threadM18 × 1
Sensing range5–100 mm on 90% remission reference white, DIN 5033
Maximum sensing range3–115 mm on 90% remission reference white, DIN 5033
Other reference-target rangesBlack 6%: 15–50 mm sensing, 10–60 mm maximum; gray 20%: 10–70 mm sensing, 5–85 mm maximum
Light sourceVisible red PinPoint LED; 650 nm
Average LED service life100,000 h at +25 °C
Light spot sizeØ8 mm at 100 mm
AdjustmentSensing-range potentiometer, 270°
Switching outputSingle PNP output
Switching modeFixed light switching
Signal voltage HIGH/LOWSupply voltage minus no more than 3 V / approximately 0 V
Output current≤100 mA; maximum 50 mA when supply >24 V or ambient temperature >49 °C
Response time<1,000 µs signal transit time with resistive load
Switching frequency500 Hz at 1:1 light/dark ratio
ConnectionM12 three-pin male connector
Pin assignmentCD-045: 1 BN=L+; 3 BU=M; 4 BK=Q
Power supply10–30 V DC; short-circuit-protected network, maximum 8 A
Ripple<5 Vpp; remain within supply-voltage tolerances
Current consumption30 mA
Circuit protectionSupply reverse-polarity protection; inputs and output reverse-polarity protection; output overcurrent and short-circuit protection
Protection classIII
Housing materialABS plastic
Optics materialPMMA plastic
Mounting hardwareTwo plastic fastening nuts supplied; 22 mm across flats
IndicatorsGreen continuously on: power on; yellow continuously on: object present, off: object absent
IP ratingIP67
Operating temperature−25 to +55 °C at supply ≤24 V and output current <50 mA
Storage temperature−40 to +70 °C
EMCEN 60947-5-2
UL filesNRKH.E348498 and NRKH7.E348498
ECOLAB certificateListed

Industrial Applications

1. Checking an insert in an indexed assembly fixture

An assembly fixture can hold an opaque insert at a repeatable distance beside the sensor’s radial optical field. The 270° potentiometer establishes the reflected-light condition, and external inspection logic samples the fixed PNP output after the fixture settles. Actual insert reflectance and the surrounding fixture determine the commissioned distance within the documented reference-target ranges.

Problem Solved

A reflected-light condition at the settled fixture gives external inspection logic an insert-present reference, helping identify an empty assembly location before the next process operation.

Insert inspection Radial optics PNP

2. Counting separated components along a feed guide

A feed guide can move separated opaque components through the radial optical field and send the PNP transitions to an external counter. The 500 Hz rating and response below 1,000 µs define the sensor timing basis. Setup establishes sensitivity with representative component surfaces and checks actual spacing, optical coverage and remission so successive components produce distinct events.

Problem Solved

Separate reflected-light transitions provide external counting logic with component-passage events, supporting production tracking with the sensor and its connection arranged on one mounting side.

Component counting 500 Hz Reflected light

3. Timing occupancy of a conveyor transfer location

A transfer location can present a defined opaque load surface within the adjusted sensing zone. The fixed light-switching output indicates the reflected-light condition, while an external controller measures how long that state persists. Comparing the duration with the intended transfer sequence helps identify a load remaining at the monitored position, with darker surfaces using the shorter documented reference ranges.

Problem Solved

A sustained target-present condition gives external transfer logic a basis for identifying an occupied handoff, helping coordinate upstream release when the monitored load has not cleared.

Transfer occupancy External dwell timing Fixed light switching
Select your currency