Model Identifier SPTW-B2R-G14-A-M12
Official Part Number 8000100
GTIN Standard 4052568255954

Technical Overview

The Festo SPTW-B2R-G14-A-M12 is a high-performance pressure transmitter utilizing a piezoresistive sensor for the measurement of relative pressure in both liquid and gaseous media. It features a broad operating temperature range from 0 to 80 °C and provides an analogue output of 4-20 mA. Designed for durability in demanding environments, it offers IP67 protection and high-alloy stainless steel construction for media-contacting components, ensuring a high corrosion resistance class (CRC 4).

Key Features

  • Piezoresistive pressure measurement method
  • Suitable for liquid and gaseous media
  • Analog output 4 - 20 mA
  • High corrosion resistance class CRC 4
  • IP67 degree of protection
  • M12x1 electrical connection with screw-type lock
  • Material housing in high-alloy stainless steel
  • Reverse polarity protection for operating voltage
  • Short circuit current rating included
  • LABS (PWIS) conformity VDMA24364 zone III

4-20 mA analogue output with an accuracy of 1 %FS and a repetition accuracy of 0.1 %FS for precise pressure monitoring.

Technical Specification Matrix

ParameterValue
Symbol00991968
ApprovalRCM trademark c UL us listed (OL)
CE markTo EU EMC Directive In accordance with EU RoHS Directive
UKCA markingTo UK RoHS instructions
Note on materialsRoHS-compliant
Measured variableRelative pressure
Measurement methodPiezoresistive pressure sensor
Start value for pressure measuring range (MPa)-0.1 MPa
Start value for pressure measuring range (bar)-1 bar
Start value for pressure measuring range (psi)-14.5 psi
End value for pressure measuring range (MPa)0.1 MPa
End value for pressure measuring range (bar)1 bar
End value for pressure measuring range (psi)14.5 psi
Max. overload pressure2 bar
Overload pressure (MPa)0.2 MPa
Overload pressure (bar)2 bar
Overload pressure (psi)29 psi
Operating mediumLiquid media Gaseous media
Media temperature0 °C ... 80 °C
Ambient temperature0 °C ... 80 °C
Accuracy in ± % FS1 %FS
Repetition accuracy in ± %FS0.1 %FS
Analogue output4 - 20 mA
Linearity error in ± %FS0.5 %FS
Short circuit current ratingyes
Operational voltage rangeDC 8 V ... 30 V
Reverse polarity protectionFor operating voltage
Electrical connection 1, connection typePlugs
Electrical connection 1, connector systemM12x1, A-coded to EN 61076-2-101
Electrical connection 1, number of connections/cores4
Electrical connection 1, type of mountingScrew-type lock
Electrical connection 1, connection pattern00995386
Material connector housingPA
Type of mountingVia female thread With accessories
Mounting positionoptional
Pneumatic connectionG1/4
Product weight80 g
Material housingVMQ (silicone) High-alloy stainless steel
Material in contact with the mediumHigh-alloy stainless steel
Degree of protectionIP67
Corrosion resistance class CRC4 - Very high corrosion stress
LABS (PWIS) conformityVDMA24364 zone III

Industrial Applications

1. Chemical Dosing Tank Vacuum and Pressure Control

Utilizing the pressure transmitter to monitor slight vacuum and low-pressure cycles in highly corrosive chemical dosing tanks. The high-alloy stainless steel construction in contact with the medium and CRC 4 rating (very high corrosion stress) ensure longevity when exposed to aggressive liquid or gaseous media.

Problem Solved

Eliminates frequent sensor failure caused by corrosive chemical exposure while accurately maintaining tank pressure between -1 and 1 bar, preventing tank deformation and ensuring consistent fluid dosing.

Corrosion resistance class CRC 4High-alloy stainless steel-1 to 1 bar rangeLiquid media

2. Pump Cavitation Prevention in Wastewater Treatment

Deployed at the suction inlet of industrial centrifugal pumps to precisely measure relative pressure from -1 bar up to 1 bar. The robust IP67 degree of protection and piezoresistive measurement method provide reliable continuous 4-20mA signals back to the PLC over long cable runs, immune to electrical noise.

Problem Solved

Prevents pump cavitation and expensive dry-running damage by instantly detecting destructive vacuum spikes in the suction line, ensuring reliable continuous operation in harsh, wet environments.

IP67 degree of protectionPiezoresistive pressure sensorAnalogue output 4 - 20 mARelative pressure

3. Low-Pressure Corrosive Gas Line Leak Detection

Monitoring pressure stability in low-pressure industrial gas supply manifolds. The sensor's 0.1 %FS repetition accuracy allows it to detect very minor pressure fluctuations, while the standard G1/4 pneumatic connection and M12x1 plug facilitate seamless integration into existing pipeline infrastructure.

Problem Solved

Rapidly identifies micro-leaks or flow interruptions in low-pressure gaseous media networks, allowing for predictive maintenance and averting hazardous gas accumulation or process shutdowns.

Gaseous media0.1 %FS repetition accuracyG1/4 pneumatic connectionM12x1 electrical connection

[Download-Datasheet]