Phoenix Contact DEK-OV-5DC_24DC_3 Solid State Relay

USD 56.72

Compact 6.2mm solid-state relay for 5V DC input and 3-30V DC/3A output, offering 2.5 kVrms isolation and DIN rail mounting.

Top Brands > Phoenix Contact > Phoenix Contact Solid-state Relay Terminal Blocks

Phoenix Contact DEK-OV-5DC_24DC_3 Solid State Relay

Model Identifier DEK-OV- 5DC/ 24DC/ 3
Official Part Number 2941361
GTIN Standard 4017918080389

Technical Overview

Compact 6.2mm solid-state relay for 5V DC input and 3-30V DC/3A output, offering 2.5 kVrms isolation and DIN rail mounting.

Key Features

  • Electrical isolation between input and output at up to 2.5 kVrms
  • Wear-free switching technology
  • Integrated input circuit
  • Status indicator via yellow LED
  • Integrated output protective circuit (Reverse polarity and surge protection)
  • Labeling and mounting with user-friendly modular terminal blocks
  • Designed for DIN rail mounting
  • Compact terminal block width of 6.2 mm
  • Screw connection method

Electrical isolation between input and output at up to 2.5 kVrms, ensuring enhanced safety and protection for sensitive control systems.

Technical Specification Matrix

ParameterValue
Nominal Input Voltage5 V DC
Input Voltage Range4 V DC ... 6 V DC
Typical Input Current11 mA
Output Voltage Range3 V DC ... 30 V DC
Limiting Continuous Current (Output)3 A
Test Voltage (Input/Output Isolation)2.5 kV AC (50 Hz, 1 min.) / 2.5 kVrms
Width6.2 mm
Height80 mm
Depth56 mm
Ambient Temperature (Operation)-20 °C ... 60 °C
Ambient Temperature (Storage/Transport)-20 °C ... 70 °C
Connection MethodScrew connection
Mounting TypeDIN rail mounting
Output Circuit2-conductor, floating
Typical Response Time40 µs
Typical Turn-off Time200 µs
Transmission Frequency300 Hz
Physical Weight (kg)0.02
Dimensions L x W x H (cm)5.6 x 0.62 x 8

Industrial Applications

1. Industrial PLC/DCS Signal Interfacing

This solid-state relay effectively interfaces low-voltage (5V DC) control signals from PLCs or DCS systems to higher voltage (up to 30V DC) industrial loads like small solenoid valves, contactors, or indicator lights. The robust 2.5 kVrms isolation provides critical protection for sensitive control electronics against electrical noise and voltage spikes from the load side, enhancing system reliability and longevity.

Problem Solved

Protects expensive PLC/DCS systems by providing galvanic isolation and efficiently translates low-level control signals to reliably drive higher power industrial loads, ensuring wear-free and precise switching operations.

PLC interfacingDCS systemsgalvanic isolationindustrial loadssignal amplificationnoise suppressionwear-free switching

2. Automated Test Equipment (ATE) for Low Current DC Switching

Ideal for automated test setups requiring precise and fast switching of DC signals or low-current loads up to 3A. Its solid-state design ensures reliable, wear-free, and silent operation. The compact 6.2mm width allows for high-density integration within complex test fixtures, optimizing space utilization.

Problem Solved

Enables high-speed, repeatable, and silent switching of DC test signals or small loads without mechanical wear, significantly improving the lifespan, accuracy, and throughput of automated test equipment.

ATEDC switchinghigh-speed switchingcompact designwear-freetest fixturessignal routing

3. Building Automation and HVAC Control

Suitable for switching low-voltage DC actuators, dampers, or small fan motors (up to 3A) in building automation and HVAC systems. This solid-state relay offers reliable, quiet operation and essential protection against electrical disturbances. The wide operating temperature range of -20°C to 60°C makes it suitable for diverse environmental conditions found in equipment rooms.

Problem Solved

Provides a compact, reliable, and quiet method for controlling various DC loads in building management systems, extending system longevity by eliminating mechanical relay wear and safeguarding critical control circuits from electrical issues.

HVAC controlbuilding automationDC actuatorsfan controlquiet operationelectrical isolationtemperature stability