Siemens SINAMICS G120XA 1.5 kW 3AC Frequency Converter

USD 135.86

1.5 kW 3-phase AC frequency converter, 380-440V input, 400V output, V/f and sensorless vector control, IP20, integrated fan. Supports Modbus RTU.

SKU Siemens-6SL3220-1YD14-0UB0 Category
Top Brands > Siemens > Siemens Industry-specific Frequency Converters

Siemens SINAMICS G120XA 1.5 kW 3AC Frequency Converter

Model Identifier SINAMICS G120XA
Official Part Number 6SL3220-1YD14-0UB0
GTIN Standard 4042948679425

Technical Overview

1.5 kW 3-phase AC frequency converter, 380-440V input, 400V output, V/f and sensorless vector control, IP20, integrated fan. Supports Modbus RTU.

Key Features

  • Three-phase AC input (380-440 V, 47-63 Hz) and output (400 V).
  • Rated power of 1.50 kW (LO) with a maximum output current of 4.50 A.
  • Supports V/f linear/square-law, FCC, and sensorless vector control up to 550 Hz.
  • Equipped with 6 standard digital inputs (11 V/5 V switching), 4 digital relay changeover contact outputs (DC 30 V, 1.0 A), and 2 differential analog inputs/outputs.
  • Integrated PTC/KTY interface for accurate motor temperature monitoring (PTC, KTY, PT1000, Thermo-Click).
  • Communication via USS, Modbus RTU, and BACnet MS/TP protocols.
  • IP20 / UL open type degree of protection and FSA frame size.
  • Operates with IE2 efficiency class and a high power factor (0.99).
  • Compact dimensions: 73 mm (W) x 232 mm (H) x 209 mm (D).
  • Wide operating temperature range from -20 °C to 60 °C at altitudes up to 1,000 m.
  • Screw-type terminals for secure signal, line, and motor connections.

Integrated Air Cooling and IE2 Efficiency Class for 1.5 kW 3AC Motor Control

Technical Specification Matrix

ParameterValue
Input Number of Phases3 AC
Input Line Voltage380 ... 440 V +10%-20%
Input Line Frequency47 ... 63 Hz
Input Rated Current (LO)3.60 A
Output Number of Phases3 AC
Output Rated Voltage400 V
Output Rated Power IEC 400V (LO)1.50 kW
Output Rated Current 400V (IN)4.10 A
Output Rated Current 380V (IN)4.10 A
Output Rated Current (LO)4.10 A
Output Max. Output Current4.50 A
Output Pulse Frequency4 kHz
Output Frequency for Vector Control0 ... 240 Hz
Output Frequency for V/f Control0 ... 550 Hz
Overload Capability (Low Overload LO)110% base load current IL for 60 s in a 600 s cycle time
Power Factor λ0.75 ... 0.93
Power Factor cos φ 10.99
Efficiency η0.97
Sound Pressure Level (1m)55 dB
Power Loss0.072 kW
Integrated Filter ClassUnfiltered
EMC Category (with accessories)without
Safety Function Safe Torque Offwithout SIRIUS device (e.g. via S7-1500F)
Communication ProtocolsUSS, Modbus RTU, BACnet MS/TP
Standard Digital Inputs Number6
Standard Digital Inputs Switching Level 0 → 111 V
Standard Digital Inputs Switching Level 1 → 05 V
Standard Digital Inputs Max. Inrush Current15 mA
Fail-safe Digital Inputs Number0
Digital Outputs Number as Relay Changeover Contact4
Digital Outputs (Resistive Load)DC 30 V, 1.0 A
Digital Outputs Number as Transistor0
Analog / Digital Inputs Number2 (Differential input)
Analog / Digital Inputs Resolution12 bit
Analog / Digital Inputs Switching Threshold 0-14 V
Analog / Digital Inputs Switching Threshold 1-01.6 V
Analog Outputs Number2 (Non-isolated output)
PTC/KTY Interface1 motor temperature sensor input, sensors that can be connected: PTC, KTY, PT1000 and Thermo-Click, accuracy ±5 °C
V/f Linear / Square-law / ParameterizableYes
V/f with Flux Current Control (FCC)Yes
V/f ECO Linear / Square-lawYes
Sensorless Vector ControlYes
Vector Control, with SensorNo
Encoderless Torque ControlYes
Torque Control, with EncoderNo
Standard Board Coating TypeClass 3C2, according to IEC 60721-3-3: 2002
Cooling MethodAir cooling using an integrated fan
Cooling Air Requirement0.005 m³/s (0.177 ft³/s)
Installation Altitude1,000 m (3,280.84 ft)
Operating Ambient Temperature-20 ... 60 °C (-4 ... 140 °F)
Transport Ambient Temperature-40 ... 70 °C (-40 ... 158 °F)
Storage Ambient Temperature-40 ... 70 °C (-40 ... 158 °F)
Max. Operating Relative Humidity95% At 40 °C (104 °F), condensation and icing not permissible
Signal Cable Conductor Cross-section0.15 ... 1.50 mm² (AWG 24 ... AWG 16)
Line Side Connection VersionScrew-type terminal
Line Side Conductor Cross-section1.50 ... 2.50 mm² (AWG 16 ... AWG 14)
Motor End Connection VersionScrew-type terminals
Motor End Conductor Cross-section1.50 ... 2.50 mm² (AWG 16 ... AWG 14)
PE ConnectionOn housing with M4 screw
Max. Motor Cable Length (Shielded)150 m (492.13 ft)
Max. Motor Cable Length (Unshielded)300 m (984.25 ft)
Degree of ProtectionIP20 / UL open type
Frame SizeFSA
Compliance with StandardsCE, EAC, RCM, RoHS II
CE MarkingEMC Directive 2004/108/EC, Low-Voltage Directive 2006/95/EC
Converter Efficiency ClassIE2
Comparison with Reference Converter (90% / 100%)35.3%
Physical Weight (kg)3.1
Dimensions L x W x H (cm)20.9 x 7.3 x 23.2

Industrial Applications

1. Conveyor Belt Speed Control in Logistics Hubs

The SINAMICS G120XA can precisely control the speed of conveyor belts in logistics and material handling systems, optimizing throughput and reducing energy consumption. Its 1.50 kW rated power and V/f control capabilities allow for smooth acceleration and deceleration of motors, minimizing mechanical stress and wear on equipment. The integrated fan cooling and wide operating temperature range (-20 to 60 °C) ensure reliable performance in demanding warehouse environments.

Problem Solved

Inefficient material flow and excessive energy consumption in conveyor systems due to fixed-speed operations.

V/f control1.50 kW3-phase ACenergy efficiencymaterial handlinglogistics

2. Pump Control for Water Treatment Facilities

This drive is ideal for regulating pumps in water treatment plants, where precise flow control and energy savings are critical. The 0-550 Hz V/f control output frequency allows for fine-tuning pump speeds to match demand, significantly reducing power consumption. Its IP20 rating makes it suitable for integration into control cabinets in industrial settings, and the Modbus RTU communication enables seamless integration with existing SCADA systems for optimized water management.

Problem Solved

High energy costs and inconsistent flow rates in water pumping operations, leading to inefficient treatment processes.

Pump controlV/f control0-550 Hz1.50 kWModbus RTUenergy savingswater treatment

3. Fan and Blower Regulation in HVAC Systems

The SINAMICS G120XA can be utilized to regulate the speed of fans and blowers in large industrial HVAC (Heating, Ventilation, and Air Conditioning) systems. The ability to control output frequency up to 550 Hz for V/f control, combined with its 1.50 kW power rating, allows for dynamic adjustment of airflow based on environmental conditions, leading to improved air quality and substantial energy savings. The low sound pressure level of 55 dB ensures minimal noise impact in operational areas.

Problem Solved

High energy consumption and fixed airflow in industrial ventilation systems, resulting in suboptimal climate control and increased operational costs.

HVACfan controlblower regulationV/f control0-550 Hzenergy efficiencysound pressure