Banner SC10-2roe Safety Controller

USD 635.00

24 V dc safety controller with 10 safe inputs, 2 relay outputs, 4 convertible inputs, IP20, PL e, Cat. 4, SIL 3.

SKU Banner-806222 Category
Top Brands > Banner > Safety Controllers

Banner SC10-2roe Safety Controller

Model Identifier SC10-2roe
Official Part Number 806222
GTIN Standard NA

Technical Overview

Banner SC10-2roe is a compact DC safety controller / relay hybrid with 10 safe inputs, 4 convertible inputs, and 2 independently controlled safe relay outputs. It supports dual-channel safety input modes, configurable input logic, and industrial safety device integration including E-stops, light curtains, mat switches, gate switches, and two-hand controls. The unit is rated IP20, operates from 24 V dc, and includes industrial network support for Modbus/TCP, EtherNet/IP, PCCC, and PROFINET. The datasheet lists spring-clamp terminals, integrated diagnostics, and safety performance ratings including PL e, Category 4, and SIL 3.

Key Features

  • 10 safe inputs and 4 convertible inputs
  • 2 independently controlled safe outputs
  • Output configuration: 2 sets of 3 NO
  • Supports E-stops, rope pulls, mats, two-hand controls, and gate switches
  • Dual-channel and single-channel safety input support
  • Integrated diagnostics via in-series diagnostics
  • Industrial network support: EtherNet/IP, Modbus/TCP, PCCC, and PROFINET
  • Spring-clamp terminal connection
  • IP20 enclosure rating
  • Safety ratings: PL e, Category 4, SIL 3

10 safe inputs, 2 independently controlled relay outputs, and configurable industrial safety I/O in a compact 24 V dc platform.

Technical Specification Matrix

ParameterValue
PowerDC
IP RatingIP20
Number of ISD Chans2
Number of ISD Devices64
Supply Voltage24 V dc
Item StatusReleased
Device TypeSafety Controller
In-Series DiagnosticsYes
Safety Module TypeBase Controller
LCD DisplayNo
ExpandableNo
Dimension (H x W x D in mm)115 x 45 x 100
Relative Humidity90% @ 50 °C
Max Operating Temperature55 °C
Input OperationSimultaneous or Concurrent
Number of Safe Inputs10
Input ConfigurationConfigurable
Number of Convertible Inputs4
Safety Input - Dual Channel (Dry Contact)5-50 mA @ 24 V dc
Safety Input - Dual Channel (Solid-State)50 mA @ 15 - 30 V dc
Safety Input - Reset5-50 mA @ 24 V dc
Independently Controlled Safe Outputs2
Output Configuration2 sets of 3 NO
Non Safe Output ConfigurationUp to 4 PNP
Non Safe Output Rating80 mA @ 24 V dc (individual) maximum; overcurrent protected
Safe Output RatingRelay - 6 A
Splittable Safe OutputNo
Mechanical Life (Operations in Millions)20
Power Consumption0.24 A (no load, relays on), 0.53 A (full load, relays on)
Response Time (ms)See Software Configuration Summary
Terminal TypeSpring Clamp
Removable TerminalsNo
Vibration9-150 Hz at 1g occasional/0.5g continuous
Electrical Life (Cycles @ VA)50,000 at full resistive load
PL Ratinge
Safety Category Rating4
SIL Rating3
SISTEMAPFHd = 5.0 x 10-10
THC RatingIIIC
Safety Input - Single Channel5-50 mA @ 24 V dc
Input Resistance150 Ω max. per lead
E-Stops/Rope PullsYes
Safety MatYes
Motor SpeedNo
Two-Hand ControlsYes
MutingYes
Gate Switch (NC/NC) InputYes
Gate Switch (NC/NO) InputYes
Gate Switch (OSSD) InputYes
Light Curtains/Scanner with EDM InputYes
Light Curtains/Scanner without EDM InputYes
EtherNet/IPYes
Common Ethernet ProtocolNo
Modbus/TCPYes
PCCCYes
PROFINETYes
Recovery Time250 (typical), 400 (max)
EPLAN StatusPublished
EPLAN Original Sent Date06/15/2022

Industrial Applications

1. Safety gate interlock for automated cells

Manages gate switch inputs and safety relay outputs to stop machinery when access doors are opened.

Problem Solved

Prevents hazardous machine motion during operator access with Category 4, PL e safety architecture.

gate switchCategory 4PL esafety relay output24 V dc

2. Light curtain and scanner safety interface

Integrates light curtains or scanners with or without EDM while providing controlled safe outputs to shut down actuators.

Problem Solved

Solves multi-device safeguarding in guarded automation lines without a separate relay matrix.

light curtainscannerEDMOSSDsafe inputssafe outputs

3. Two-hand and emergency stop control for press stations

Accepts two-hand controls, E-stops, and rope pulls to enforce safe operator presence and emergency shutdown.

Problem Solved

Ensures hazardous equipment cannot cycle unless the operator is clear and intentionally actuating the machine.

two-hand controlE-stoprope pullSIL 3spring clamp terminals