| Nominal voltage for logic power supply DC | 24 V |
| Nominal operating voltage DC | 24 V |
| Nominal current logic power supply | 0.15 A |
| Permissible range for logic voltage | ±20% |
| Current consumption of logic power supply without clamping brake | 0.2 A |
| Short circuit current rating | Yes, with one exception: Contact C1/C2 |
| Current rating at 40° C | 0.2 A |
| Fuse protection (short circuit) | No |
| Digital output design | Potential-free signal contact; 3 safe, 2-channel semiconductor outputs |
| Number of digital logic inputs | 10 |
| Digital outputs, switching logic | Semiconductor outputs: parameterisable PNP (positive switching) 2-; channel equivalent/antivalent |
| LED display, product-specific | Error (red); Normal operation (green); Safe state (yellow) |
| Safety function | Safe brake control (SBC); Safe Speed Range (SSR); Safe Speed Monitor (SSM); Safe torque off (STO); Safely limited speed (SLS); Safe Operating Stop (SOS); Safe Stop 1 (SS1); Safe Stop 2 (SS2) |
| Probability of Failure per Hour (PFH) | 9.5E-09 |
| Proof test interval | 20 y |
| Hardware fault tolerance | 1 |
| SFF Safe Failure Fraction | 99.5 % |
| Certified for safety function to ISO 13849 and IEC 61508 (SIL) | Product can be used in SRP/CS up to SIL 3 (high demand) |
| Safety Integrity Level (SIL) | Safe stop 2 (SS2)/SIL 3; Safe stop 1 (SS1)/SIL 3; Safe brake control (SBC)/SIL 3; Safely limited speed (SLS)/SIL 3; Safe operating stop (SOS)/SIL 3; Safe speed monitor (SSM)/SIL 3; Safe Speed Range (SSR)/SIL 3; Safe torque off (STO)/SIL 3 |
| Performance Level (PL) | Safe brake control (SBC)/category 4, Performance Level e; Safely limited speed (SLS)/category 3, performance level e; Safe operating stop (SOS)/category 3, performance level e; Safe stop 1 (SS1)/category 3, Performance Level e; Safe stop 2 (SS2)/category 3, Performance Level e; Safe speed monitor (SSM)/category 3, Performance Level e; Safe speed range (SSR)/category 3, Performance Level e; Safe Torque Off (STO)/category 4, performance level e |
| Diagnostic coverage | 97.5 % |
| Certified for safety functions to ISO 13849 (PL) | Product can be used in SRP/CS up to category 4, PL e |
| Approval | German Technical Control Board (TÜV) |
| CE mark (see declaration of conformity) | To EU EMC Directive; To EC Machinery Directive; In accordance with EU RoHS Directive |
| UKCA marking (see declaration of conformity) | To UK instructions for EMC; To UK regulations for machines; To UK RoHS instructions |
| Certificate issuing authority | TÜV Rheinland 01/205/5165.03/24 |
| LABS (PWIS) conformity | VDMA24364 zone III |
| Storage temperature | -25 °C...55 °C |
| Relative air humidity | 5 - 90%; Non-condensing |
| Degree of protection | IP20; In mounted state |
| Ambient temperature | 0 °C...40 °C |
| Physical Weight (kg) | 0.22 |
| Type of mounting | Plug-in module for CMMP-AS...-M3 |
| Note on materials | RoHS compliant |
| Mounting position | Any |
| Wire ends | Wire ferrule |
| Connection cross section | 0.25 mm²...0.5 mm² |
| Electrical connection | Screw terminal; Straight plug |
| Display | Green/yellow/red LED |
| Operator controls | DIL switch |
| Specification logic input | IEC 61131-2, type 3 |
| Features of logic input | 4 safe, 2-channel inputs Equivalent/antivalent switching Test pulses; configurable Function configurable; 6 safe, 1-channel inputs Test pulses configurable |
| Working range of logic input | 13 V...28.8 V |
| Max. nominal input current | 0.015 A |
| Debounce time for inputs | 0.3 ms |
| Current rating per output | 50 mA |
| Max. current digital logic outputs | 50 mA |
| Fuse capacity of outputs | Short-circuit and cross-circuit monitoring |
| Min. cycle time | 2 ms |
| Parameterisation | Via SafetyTool |
| Dimensions L x W x H (cm) | 9.91 x 11.22 x 2.87 |