SICK 6051030 CM12-08EBP-KC1 Teach-In Capacitive Sensor

USD 154.44

CM12-08EBP-KC1 provides PNP/NPN NC or NO capacitive sensing, button and external teach-in, 15 Hz switching and an IP68 M12 threaded housing.

SKU SICK-6051030 Category
SICK CM

SICK CM12-08EBP-KC1 Teach-In Capacitive Sensor

BrandSICK
Model IdentifierCM12-08EBP-KC1
Official Part Number6051030

Technical Overview

The SICK CM12-08EBP-KC1 is a capacitive proximity sensor with an M12 × 1 threaded housing and PNP/NPN with NC or NO function output. It detects nearby material by evaluating changes in capacitance, supporting qualified metal and nonmetal targets. Its specified range is 0.5–8 mm non-flush or 0.5–4 mm flush, with actual reach dependent on material and installation. The local button and external wire teach-in adapts sensitivity to the target and surroundings. The sensor operates from 10–36 V DC at 15 Hz and connects through an M12 four-pin male connector. Its plastic housing provides IP68 protection, and two PA12 mounting nuts are included. Material reduction factors guide commissioning.

M12 × 1 capacitive sensor with PNP/NPN with NC or NO function output, 0.5–8 mm non-flush or 0.5–4 mm flush range, local button and external wire teach-in, 15 Hz switching and M12 four-pin male connector.

Key Features

  • Capacitive proximity sensing for qualified metal and nonmetal targets
  • M12 × 1 threaded housing
  • 0.5–8 mm non-flush or 0.5–4 mm flush specified sensing range
  • Pnp/npn with nc or no function output
  • Local button and external wire teach-in
  • 10–36 V DC operating supply; 15 Hz switching
  • M12 four-pin male connector
  • IP68 protection; IP68 test: 1.3 m water depth for 60 min
  • Material-dependent range; manufacturer reference reduction factors available
  • Two PA12 plastic mounting nuts included

Adjust capacitive detection for qualified metal or nonmetal targets and provide a discrete PNP/NPN with NC or NO function signal through an M12 × 1 threaded sensor.

Technical Specification Matrix

ParameterValue
Functional principleCapacitive proximity sensing
Housing designMetric threaded housing
Thread sizeM12 × 1
Housing diameter12 mm
Sensing range0.5–8 mm non-flush or 0.5–4 mm flush
Assured sensing distance5.76 mm
InstallationNon-flush or flush; flush installation requires teach-in
Switching outputPnp/npn with nc or no function
Output functionNC or NO
Output characteristicWire configurable; automatic detection
Electrical wiringDC, 4-wire
AdjustmentLocal button and external wire teach-in
Switching frequency15 Hz
Material reduction factorsReference values, material dependent: metal 1; water 1; PVC approximately 0.4; oil approximately 0.25; glass 0.6; ceramics 0.5; alcohol 0.7; wood 0.2–0.7
Power supply10–36 V DC
Residual ripple≤10% of supply voltage
Voltage drop≤2.5 V DC at maximum output current
Current consumption12 mA without load
Initialization time≤120 ms
Hysteresis3–20% of sensing range
Reproducibility≤5% of sensing range at constant supply voltage and ambient temperature
Output current≤200 mA
Short-circuit protectionYes
Power-up pulse suppressionYes
ConnectionM12 four-pin male connector
Housing materialPlastic
IP ratingIP68
IP68 test condition1.3 m water depth for 60 min
Operating temperature−20 to +85 °C
Storage temperature−40 to +85 °C
Maximum tightening torque≤1 Nm
Items suppliedTwo PA12 plastic mounting nuts
MTTFD603 years
Diagnostic coverage DCavg0%
Mission time20 years
UL fileNRKH.E191603
Pin assignment1/BN: L+; 4/BK: NO/NC; 2/WH: Teach; 3/BU: M
IndicatorsYellow: output active; green: power and signal reserve
EMCEN 60947-5-2; datasheet requires sensor grounding and minimum 1 × Sn for non-flush installation
Shock resistance30 g for 11 ms
Vibration resistance10–55 Hz at 1 mm amplitude

Industrial Applications

1. Checking a nonmetal part in an assembly fixture

An assembly fixture can place a qualified nonmetal part near the sensing face and use the PNP/NPN with NC or NO function signal to confirm its local presence. The local button and external wire teach-in adapts sensitivity to the actual target and surrounding fixture. Commissioning compares empty and occupied states at the installed spacing, taking the documented material reduction factors into account.

Problem Solved

A local presence signal helps the controller detect a missing part before the next assembly step, without requiring a metal target on the component or a contact actuator.

Part presence Nonmetal targets Capacitive sensing

2. Detecting a liquid at a point in a nonmetal vessel

A suitable nonmetal vessel can position the sensor outside its wall at the desired detection point. After testing the actual wall, liquid and spacing, the local button and external wire teach-in sets a threshold between empty and filled conditions. The PNP/NPN with NC or NO function output provides a discrete point-level event to a compatible controller; the specified range remains subject to the installed materials.

Problem Solved

A qualified external point-level signal helps the process controller identify liquid reaching the monitored height while avoiding a probe inside the vessel and preserving the vessel wall.

Point level External mounting Qualified vessel wall

3. Monitoring granulate at a feed inspection window

A granulate feeder can place the sensor beside a suitable nonmetal inspection window to check whether material occupies the monitored location. The local button and external wire teach-in is set using the actual granulate, window and installation spacing. Empty and filled tests, including expected moisture and buildup conditions, qualify the discrete output before it is used to coordinate feeding.

Problem Solved

A local material-presence event helps the controller identify an empty feed location or arrival of replenishment material, supporting feed sequencing without placing a mechanical paddle in the granulate.

Granulate feed Material presence Threshold setup