product brand name | SIRIUS |
product designation | Power contactor |
product type designation | 3RT6 |
General technical data | |
size of contactor | S00 |
product extension auxiliary switch | Yes |
power loss [W] for rated value of the current ● at AC in hot operating state per pole ● without load current share typical |
0.42 W 1.05 W |
type of calculation of power loss depending on pole | quadratic |
insulation voltage rated value | 690 V |
degree of pollution | 3 |
surge voltage resistance rated value | 6 Kv |
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1 |
400 V |
shock resistance at rectangular impulse ● at AC |
6,7g / 5 ms, 4,2g / 10 ms |
shock resistance with sine pulse ● at AC |
10,5g / 5 ms, 6,6g / 10 ms |
mechanical service life (operating cycles) ● of contactor typical ● of the contactor with added auxiliary switch block typical |
30 000 000 10 000 000 |
Substance Prohibitance (Date) | 5/1/2012 |
Weight | 0.233 kg |
Ambient conditions | |
installation altitude at height above sea level maximum | 2 000 m |
ambient temperature ● during operation ● during storage |
-25 … +60 °C -55 … +80 °C |
Main circuit | |
number of poles for main current circuit | 3 |
number of NO contacts for main contacts | 3 |
number of NC contacts for main contacts | 0 |
operating voltage ● at AC-3 rated value maximum ● at AC-3e rated value maximum |
690 V 690 V |
operational current ● at AC-1 up to 690 V — at ambient temperature 40 °C rated value — at ambient temperature 60 °C rated value ● at AC-3 — at 400 V rated value — at 690 V rated value ● at AC-3e — at 400 V rated value — at 690 V rated value |
18 A 7 A 7 A |
connectable conductor cross-section in main circuit at AC 1 ● at 60 °C minimum permissible ● at 40 °C minimum permissible |
2.5 mm² |
operational current for approx. 200000 operating cycles at AC-4 ● at 400 V rated value ● at 690 V rated value |
2.6 A |
operating power ● at AC-1 — at 230 V rated value — at 230 V at 60 °C rated value — at 400 V at 60 °C rated value — at 690 V at 60 °C rated value ● at AC-3 — at 230 V rated value — at 400 V rated value — at 690 V rated value ● at AC-3e — at 230 V rated value — at 400 V rated value — at 690 V rated value |
6.3 kW 1.5 kW 1.5 kW |
operating power for approx. 200000 operating cycles at AC 4 ● at 400 V rated value ● at 690 V rated value |
1.15 kW |
no-load switching frequency ● at AC |
10 000 1/h |
operating frequency ● at AC-1 maximum ● at AC-3 maximum ● at AC-3e maximum ● at AC-4 maximum |
1 000 1/h 750 1/h 750 1/h 250 1/h |
Control circuit/ Control | |
type of voltage of the control supply voltage | AC |
control supply voltage at AC ● at 50 Hz rated value 220 V ● at 60 Hz rated value |
220 V 220 V |
operating range factor control supply voltage rated value of magnet coil at AC ● at 50 Hz 0.8 … 1.1 ● at 60 Hz |
0.8 … 1.1 |
apparent pick-up power of magnet coil at AC ● at 50 Hz ● at 60 Hz |
27 VA 31.7 VA |
inductive power factor with closing power of the coil ● at 50 Hz ● at 60 Hz |
0.8 0.81 |
apparent holding power of magnet coil at AC ● at 50 Hz ● at 60 Hz |
4.2 VA 4.8 VA |
inductive power factor with the holding power of the coil ● at 50 Hz ● at 60 Hz |
0.25 0.25 |
Auxiliary circuit | |
number of NC contacts for auxiliary contacts instantaneous contact | 0 |
number of NO contacts for auxiliary contacts instantaneous contact |
1 |
operational current at AC-12 maximum | 10 A |
operational current at AC-15 ● at 230 V rated value ● at 400 V rated value ● at 690 V rated value |
10 A 3 A 1 A |
operational current at DC-12 ● at 24 V rated value ● at 110 V rated value ● at 220 V rated value |
6 A 3 A 1 A |
operational current at DC-13 ● at 24 V rated value ● at 110 V rated value ● at 220 V rated value |
6 A 1 A 0.3 A |
contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) |
UL/CSA ratings | |
yielded mechanical performance [hp] for 3-phase AC motor at 460/480 V rated value |
3 hp |
Short-circuit protection | |
design of the fuse link ● for short-circuit protection of the main circuit — with type of coordination 1 required — with type of assignment 2 required ● for short-circuit protection of the auxiliary switch required |
gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35 A |
Installation/ mounting/ dimensions | |
mounting position | +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface |
fastening method side-by-side mounting | Yes |
fastening method | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022 |
height | 57.5 mm |
width | 45 mm |
depth | 73 mm |
required spacing ● with side-by-side mounting — at the side |
0 mm |
Connections/ Terminals | |
type of electrical connection ● for main current circuit ● for auxiliary and control circuit |
screw-type terminals screw-type terminals |
type of connectable conductor cross-sections for main contacts ● solid or stranded ● finely stranded with core end processing |
2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²) 2x (0,5 … 1,5 mm²), 2x (0,75 … 2,5 mm²), 2x 4 mm² |
type of connectable conductor cross-sections ● for auxiliary contacts — solid or stranded — finely stranded with core end processing ● for AWG cables for auxiliary contacts |
2x (0,5 … 1,5 mm²), 2x (0,75 … 2,5 mm²), 2x 4 mm² |
Safety related data | |
product function mirror contact according to IEC 60947-4-1 | Yes |
Electrical Safety | |
protection class IP on the front according to IEC 60529 IP20 | IP20 |
touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front |
Weight | 0.233 kg |
---|---|
Dimensions | 6.5 × 8 × 5 cm |